← All vessels
PORTO GERMENO
PORTO GERMENO is a 2002 freight ship. The Coast Guard has recorded 30 inspections since 2010, most recently in June 2026, along with 3 deficiencies and 7 operational controls.
Records from 2010 to 2026. Most recent: inspection, 17 June 2026.
- Built
- 2002
- Last inspected
- 17 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9260902 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5LBC8
1046228
Flag
LIBERIA
—
Maury page id
psix-1046228
Inspections, by type
…with no type recorded10
Years with a record
11 calendar years (2010–2026)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it66573 - Convention (Subpart B), Gross Ton
25925 - Convention (Subpart B), Net Ton
66573 - Regulatory (Subpart C or D), Gross Ton
91250 - Displacement, Ton
67009 - Dead Weight, Ton
25925 - Regulatory (Subpart C or D), Net Ton
25925 - Convention (Subpart B), Net Ton
66573 - Regulatory (Subpart C or D), Gross Ton
91250 - Displacement, Ton
67009 - Dead Weight, Ton
25925 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
17 June 2026
Explosive Handling Operation-Administrative
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8405003
15 June 2026
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8405307
5 May 2026
Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8367088
3 May 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8360833
4 February 2026
Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8305878
3 October 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8245791
23 September 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7565168
16 September 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7556218
15 March 2022
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7407015
24 August 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7295371
24 August 2021
MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7295553
10 August 2021
Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7275891
21 August 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7038899
3 July 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6994272
26 June 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6987355
21 May 2020
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6957269
24 March 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6930995
11 September 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6809497
10 September 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6808051
8 February 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6619671
22 December 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6601912
8 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6577018
20 December 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6326972
18 December 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6325883
28 May 2014
PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4862498
4 July 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4068484
4 July 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4086099
22 November 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3896482
10 October 2010
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3863946
9 October 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3866949
Deficiency record · 3
Lifesaving › Launching Appliances › Davit
Issued 28 May 2014
Resolved
0635 - Launch Arrangt. For Rescue Boats - Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The vessel's rescue boat could not be lowered properly. 74 SOLAS (09 Cons Ed) CH III/ REG 20.1 (17ac)
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 May 2014
Resolved
1410 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel has a soft patch on the discharge line for salt water... 74 SOLAS (09 Cons Ed) CH I/REG 11a (40ac)
Engineering › Steam Boiler (propulsion) › Pump
Issued 28 May 2014
Resolved
1499 - Other (Prop and Aux. Machinery) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel boiler feed pumps...74 SOLAS (2009 Cons Ed) CH 1/ REG 11a (40ac)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.