MSC ANGELA

MSC ANGELA is a 2008 freight ship. The Coast Guard has recorded 23 inspections since 2018, most recently in July 2025, along with 12 deficiencies and 7 operational controls.

Records from 2018 to 2025. Most recent: inspection, 15 July 2025.

Built
2008
Last inspected
15 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9351593
1046289
Flag
PANAMA
Maury page id
psix-1046289

Documentation record

Tonnage as PSIX records it41225 - Convention (Subpart B), Gross Ton
53458 - Dead Weight, Metric Ton
71610 - Displacement, Metric Ton
24035 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

15 July 2025 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8185762
13 July 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8183855
21 November 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8039743
5 October 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8014361
22 September 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8007172
19 September 2024 PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8003536
11 May 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7910400
15 December 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7609640
14 December 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7608890
11 December 2022 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7604971
8 April 2022 Appeal
Administrative · Commandant (CG-CVC) · Activity 7427547
1 March 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7403623
13 September 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7311167
4 April 2019 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6650524
2 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6630489
23 December 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6602040
23 December 2018 NPV Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6602134
23 December 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6602735
25 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6567909
21 July 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6486146
29 May 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6428052
14 February 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6354953
12 February 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6353602

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 July 2025 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED EXCESSIVE OIL ACCUMULATION IN WAY OF JACKING GEAR FOR THE MAIN ENGINE, MAIN ENGINE PIPING BELOW FUEL INJECTORS, BELOW COMMON RAIL AND ASSOCIATED LAGGING, FUEL PURIFIER INLETS, AND THE LOWEST LEVEL FORWARD BUNKER STATION VALVE IN THE ENGINE ROOM. SOLAS (09) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2025
Resolved 14 July 2025
Resolution: Received Satisfactory Class Report.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 September 2024 Resolved
ALL STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. THE #1 STEERING PUMP WAS OBSERVEED TO BE DRIFTING 10 DEGREES PORT EVERY MINUTE DURING THE LOCAL STEERING TEST AND FROM THE BRIDGE STEERING UNDER NON-FOLLOW UP.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2024
Resolution: Received class report from DNV after crew completed maintenance and verifying steering gear was no longer drifting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 19 September 2024 Resolved
THE RING, LINES AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THE MARKS SHALL BE PLAINLY VISIBLE AND, IF NECESSARY, SPECIAL ARRANGEMENTS SHALL BE MADE FOR THIS PURPOSE. THE DECK LINE ON BOTH PORT AND STBD SIDES OF THE SHIP ARE PAINTED BLACK ON A BLACK BACKGROUND AND ARE NOT CLEARLY VISIBLE.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 September 2024
Resolution: Received pictures of both port and stbd deck lines, now painted of contrasting color.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 September 2024 Resolved
CYLINDERS MUST ALWAYS BE SECURED AND, WHEN NOT IN USE, THEY MUST BE STOWED IN A RACK IN AN UPRIGHT POSITION, WITH THE VALVE PROTECTION CAP IN PLACE. OXYGEN AND ACETYLENE BOTTLES NOT IN USE DID NOT HAVE PROTECTION CAPS AND THE CREW DID NOT HAVE SPARES AVAILABLE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2024
Resolved 30 September 2024
Resolution: Received pictures of both acetelyne and oxygen bottles now capped until vessel can discharge empty bottles.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 March 2022 Resolved
To prevent the ignition of combustible materials or flammable liquids, means shall be provided to control the leaks of flammable liquids. Several sections of high pressure fuel piping insulation and piping were oil soaked and soiled. The crew wrapped rags around a section of actively leaking piping, when the oil soaked rag was replaced with a clean rag, the clean rag immediately became soaked with oil. Oil would continuously drip from this rag as well as the oil soaked insulation onto the platform and into the bilges. 74SOLAS(04)II-2/4.1.1
Action required: 30 - Ship detained
Resolved 2 March 2022
Resolution: Class society conducted a survey of the fuel oil piping and found condition to be satisfactory and properly repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 March 2022 Resolved
To contain a fire in the space of origin, the ship shall be subdivided by thermal insulation and structural boundaries, thermal insulation of boundaries shall have due regard to the fire risk of the space and adjacent spaces and the fire integrity of the divisions shall be maintained at openings and penetrations. The crew acknowledged that large sections of thermal insulation has been removed to facilitate installation of a scrubber two years ago but were never provided the insulation ot replace what was removed and discarded between the cargo deck and the engine room. the impacted area requires thermal insulation in order to achieve an A30 boundary. 74SOLAS(04)II-2/9.1.2
Action required: 30 - Ship detained
Resolved 2 March 2022
Resolution: Class society conducted survey of insulation and found condition to be satisfactory and properly installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 September 2021 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed excessive accumulation of oil and oil soiled insulation in the purifying space. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2021
Resolved 13 September 2021
Resolution: Received pictures attesting to cleanup of excessive oil in the purifier room. Def cleared.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 4 April 2019 Resolved
Action: 17AC, Rectify prior to departure to satisfaction of RO and Coast Guard. Each oil-fired boiler which is intended to operate without manual supervision shall have safety arangements which shut off the fuel supply and give an alarm in the case of low water level, air supply failure or flame failure. PSCO observed multiple alarms on boiler. C/E stated the vessel is having to operate manually and stand 24 hour watch. Vessel is authorized to be unmanned machinery space. SOLAS 74 A (09) II-1/32.2
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 April 2019
Resolved 4 April 2019
Resolution: Received Class report stating that manned watch for Aux Boiler is acceptable.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 4 April 2019 Resolved
Action: 17C, Rectify prior to departure to satisfaction of Coast Guard. Whenever an accident occurs to a ship or a defect is discovered, either of which affects the safety of the ship or the efficiency or completeness of its life-saving appliances or other equipment, the master or owner of the ship shall report at the earliest opportunity to the administration. Vessel could not provide notification to class of boiler alarms. -SOLAS 74 A (09)I/11(c)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 April 2019
Resolution: Vessel notified class society.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 12 February 2018 Resolved
1499- Other(Prop. & Aux. Machinery)- The machinery, associated piping systems and fittings shall be so installed and protected as to reduce to a minimum any danger... PSCO identified mulitiple oil leaks on machinery in the engine room: substantial fuel oil leak on the main engine #3 cylinder fuel pump barrel, a leak on #8 cylinder fuel pump barrel, #1 ship service generator in vicinity of fuel oil leakage tank return line, as well as the #3 SSDG fuel oil leakage tank return line - fitted with a 5 gallon bucket at which at the time was approximately 1/3 filled with fuel oil. SOLAS74(2014 CONS.) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2018
Resolution: Received satisfactory Class Survey.
Lifesaving › Lifeboat Equipment › Rocket Parachute Flare
Issued 12 February 2018 Resolved
0610 - Lifeboat - Each survival craft shall be stowed fully equipped as required by the code. PSCO discovered both lifeboats were equipped with 03 parachute flares each. SOLAS74(2014CONS.) III/13.1.4 LSA CODE 4.1.5.1.10
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 February 2018
Resolved 12 February 2018
Resolution: Received satisfactory Class Survey.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 February 2018 Resolved
2515 - Company Responsibility and Authority - The company should establish procedures, plans and instruction including checklists as appropriate for key shipboard operations concerning the safety of the personnel, ship and protection of the enviroment. The inventory list provided for the lifeboat requires 03 parachute flares, which is insufficient in accordance with the LSA Code. SOLAS74(2014 CONS.)IX/3.1 ISM Code Part A 7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 March 2018
Resolved 12 February 2018
Resolution: Received satisfactory Class Survey.