MAURY USCG vessel records
← All vessels

BBC GDANSK

BBC GDANSK is a 2009 freight ship. The Coast Guard has recorded 19 inspections since 2016, most recently in April 2025, along with 8 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 25 April 2025.

Built
2009
Last inspected
25 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 April 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9436965
1046648
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1046648

Documentation record

Tonnage as PSIX records it6155 - Convention (Subpart B), Gross Ton
6155 - Regulatory (Subpart C or D), Gross Ton
2759 - Convention (Subpart B), Net Ton
11381 - Displacement, Ton
7715 - Dead Weight, Ton
2759 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

25 April 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8110097
15 January 2025 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8062681
21 March 2023 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7654166
20 January 2023 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7622177
12 January 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7118636
9 July 2019 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6734569
7 July 2019 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6734564
7 July 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6739680
17 April 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6404158
16 April 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6391168
31 January 2018 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6348348
18 January 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6339950
6 September 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6260716
6 September 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6327074
21 November 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6045028
20 November 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6044974
6 September 2016 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5993134
18 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5975983
30 March 2016 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5843861

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 April 2025 Resolved
For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed 2 drip plans with oil under HFO lines in purifier room and oil under SSDG #1.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 April 2025
Resolved 25 April 2025
Resolution: PSCO witnessed proper disposal of drip pans and cleaning under SSDG #1
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 20 January 2023 Resolved
CG011 - Pollution Prevention- Maintain a BWM plan that has been developed specifically for the vessel. Vessel of keel laid date 2007, is past compliance date and has not updated BWM plan to conform with requirements. No BWMS installed. -33 CFR 151.2050(G) 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2023
Resolution: Sector Miami receieved appropriate pages updating ship's BWMP.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 September 2017 Resolved
0220 - Certificates of Competency - ...Dispensations shall not be granted to...Chief Engineer...Flag...issued a dispensation allowing Second Engineering Officer to serve in capacity of Chief Engineer... - STCW Aritcle VIII (60c)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2017
Resolution: SEC HOU-GAL received a copy of the license electronically.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 September 2017 Resolved
1530 - RADAR - All ships of 3,000 gross tons and above shall have a 9Ghz radar and a 3Ghz radar or where considered appropriate by the Administration a second 9Ghz radar. The vessel's 3Ghz radar is not operating properly...74SOLAS(2014 Con)V/19.2.7 (17c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2017
Resolution: SEC HOU-GAL received a copy of the tech report electronically.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 6 September 2017 Resolved
1030 - Steering Gear Alarm - In the event of a power failure to any one of the steering gear units, an audible and visual alarm shall be given on the navigation bridge. The audible alarm on the bridge did not sound when tested...74SOLAS(2004 Con)II-1/29.2.3.5.2 (16bc)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 18 January 2018
Resolution: Documentation recieved attesting to satisfactory rectification of deficiency.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 21 November 2016 Resolved
0725 - The PSCO observed all the manual valves on the pump unit for the NOVENCO hyper mist system in the closed position rendering the system incapable of fighting a fire without manual intervention. The engine room is classed for UMS and operates as such. 74 SOLAS (14) XI-1/4.1 30AC
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2016
Resolved 22 November 2016
Resolution: Received class report stating corrective actions. See attached document.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 November 2016 Resolved
2535 - The SMS does not contain procedures or frequency for shipboard testing and maintenance of the hyper mist system. Crew was unable to find the manufacturer’s manual for the system and the crew was not familiar with testing procedures for the system. See attached Form A/B for full description. 74 SOLAS (14) IX/3.1 ISM Code Part A 10.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2016
Resolved 22 November 2016
Resolution: Received class report stating corrective actions. See attached document.
Fire Fighting › Automatic Sprinkler System › Connection to Fire Main
Issued 21 November 2016 Resolved
0725 - Paint cans in the paint locker were stored above the fixed water sprinkler system and would not be extinguished in the event of a fire. 74 SOLAS (14) II-2/14.2.1.2 10C
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 21 November 2016
Resolution: Crew moved paint cans to below the sprinkler heads.

Ownership record