MAURY USCG vessel records
← All vessels

SALISH

SALISH is a 2011 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 2016, most recently in April 2026, along with 54 deficiencies — 2 with no resolution recorded —, 1 operational control and 14 casualty investigations between 2011 and 2022.

Records from 2011 to 2026. Most recent: inspection, 2 April 2026.

Built
2011
Last inspected
2 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
…with no type recorded8
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9618329
WDF6992
1046774
Flag
UNITED STATES
Maury page id
psix-1046774

Documentation record

Registered dimensions (L × B × D)257.4 ft × 64.0 ft × 17.6 ft
Registered tonnagegross 4,623 / net 1,887
ITC dimensions (L × B × D)257.4 ft × 64.0 ft × 17.6 ft
ITC tonnagegross 4,623 / net 1,887
BuilderTODD PACIFIC SHIPYARDS · SEATTLE, WA, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4623 - Convention (Subpart B), Gross Ton
1887 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 77

2 April 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8341327
13 January 2026 Internal Structural Exam · Underwater Inspection in lieu of Drydock · Vessel Attendance · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8289493
13 January 2026 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8295562
8 January 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8291871
10 November 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8267617
29 August 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8220492
12 August 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8197730
29 April 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8123544
5 March 2025 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8084706
9 December 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8043982
4 November 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8031070
27 September 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8015687
27 September 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8015747
23 September 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8007998
14 June 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7935040
4 June 2024 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7918822
29 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7872184
22 January 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7852997
30 November 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7831864
23 August 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7775449
1 March 2023 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7642905
25 January 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7627708
17 January 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7623378
20 October 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7581210
20 October 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7581407
19 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538441
16 August 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538063
15 June 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7478719
15 June 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7480303
26 May 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7465617
10 April 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7427936
10 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7409722
10 February 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7382739
6 December 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7363525
14 September 2021 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7311299
19 June 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7230659
17 June 2021 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7228499
7 June 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7218637
6 June 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7220335
5 June 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7216952
30 May 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7210436
30 May 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7210473
8 March 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7152361
24 February 2021 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7146560
4 January 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7119508
27 November 2020 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7102616
25 August 2020 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7043423
24 February 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6914850
11 December 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6873529
12 November 2019 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6839785
15 August 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6788118
17 April 2019 Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6664548
15 April 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6663168
21 March 2019 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6646726
9 February 2019 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6626115
29 January 2019 COI Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6605431
11 December 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6597536
30 November 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6590202
30 November 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6870563
10 September 2018 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6537543
9 September 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6549517
15 May 2018 Administrative Inspection · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6414634
13 February 2018 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6352912
4 October 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6280809
23 August 2017 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6269516
8 August 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6234566
30 May 2017 Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6169411
11 May 2017 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6142034
2 February 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6082009
1 February 2017 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6089277
31 January 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6080664
4 November 2016 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6037047
4 August 2016 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5966632
9 June 2016 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5908774
5 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5908677
29 February 2016 Underwater Inspection in lieu of Drydock · Special Drydock · Deficiency Check · Internal Structural Exam · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5824289
23 February 2016 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5821811

Deficiency record · 54

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 April 2026 Resolved
All piping, valves, and fittings shall meet the applicable requirements of subchapter F (Marine Engineering). Pinhole leak in overboard piping of #2 fire pump patched with suitable temporary repair. Submit repair plan and crop and renew section of pipe as permanent repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 May 2026
Resolution: Piping section crop and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2026 Resolved
THE MINIMUM INSTRUMENTATION, ALARMS AND SAFETY CONTROLS ARE LISTED IN TABLE 62.35-50. VESSEL HAS REQUESTED TO OPERATE WITHOUT THE REQUIRED AUTOMATIC ENGINE SHUTDOWN FOR LOW LUBE OIL PRESSURE ON A LOCAL ROUTE (FAUNTLEROY, VASHON, SOUTHWORTH) THAT IS NOT AUTHORIZED ON ITS COI. VESSEL IS REQUIRED TO IMPLEMENT THE APPROPRIATE LOW LUBE OIL PRESSURE ENGINE SHUTDOWN OR PROVIDE A COMPLIANCE DEVIATION PROPOSAL WITHIN 60 DAYS TO THE OCMI FOR CONSIDERATION. -46 CFR 62.35-50
Action required: 705 - Other - as specified
Resolved 27 May 2026
Resolution: vessel back on original route.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2025 Resolved
Pipe, tubing, pipe joining fittings, and piping system components, shall meet material and standard requirements of subpart 56.60 and shall meet the certification requirements of part 50 of this subchapter. Vessel has 02 pin hole leaks in the stern tube cooling water piping in the #2 end tank room. 705 c. Vessel to repair/replace all sections of piping with pinhole leaks upon repositioning from Eagle Harbor to Pt. Defiance/Vashon, or within 30 days. 46CFR56.10-1
Action required: 705 - Other - as specified
Due 15 November 2025
Resolved 14 July 2026
Resolution: MI observed permanent satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2024 Resolved
NO REPAIRS OR ALTERATIONS AFFECTING THE SAFETY OF THE VESSEL SHALL BE MADE WITHOUT THE KNOWLEDGE OF THE OFFICER IN CHARGE, MARINE INSPECTION. VESSEL EXPERIENCED A FAILURE OF ITS NO. 1 SHAFT SEAL. VESSEL IS RESTRICTED FROM CARRYING PASSENGERS UNTIL ISSUE HAS BEEN RECTIFIED TO THE SATISFACTION OF USCG. -46 CFR 71.55-1; 701C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2024
Resolution: Vessel replaced o-ring and sea-trialed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2024 Resolved
THE MINIMUM INSTRUMENTATION, ALARMS AND SAFETY CONTROLS ARE LISTED IN TABLE 62.35-50. VESSEL HAS REQUESTED TO OPERATE WITHOUT THE REQUIRED AUTOMATIC ENGINE SHUTDOWN FOR LOW LUBE OIL PRESSURE ON A LOCAL ROUTE (FAUNTLEROY, VASHON, SOUTHWORTH) THAT IS NOT AUTHORIZED ON ITS COI. VESSEL IS REQUIRED TO IMPLEMENT THE APPROPRIATE LOW LUBE OIL PRESSURE ENGINE SHUTDOWN OR PROVIDE A COMPLIANCE DEVIATION PROPOSAL WITHIN 60 DAYS TO THE OCMI FOR CONSIDERATION. -46 CFR 62.35-50
Action required: 705 - Other - as specified
Due 14 August 2024
Resolved 9 February 2026
Resolution: Closing deficiency due to identical deficiency issued on 08JAN26 by ACT# 8291871
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2024 Resolved
Alcohol test strips on board were recently expired. Rectify prior to getting underway beyond within 2 hours transit of designated testing facility
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 June 2024
Resolution: New test kits received on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2024 Resolved
Prove proper operation of the #1SSDG J/W Pressure gauge.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 8 June 2024
Resolution: Vessel installed a rectifier due to a frequency issue with an A/C unit in the crews bearthing area.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 June 2024 No resolution recorded
Update DVTP's for SSS and ES and prove proper operation of SG3, 12, 16, 18, SP 7, 8, SSES 3, 5, 8, 9, EGES 5, 12, 14
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2024 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 4 June 2024 Resolved
Complete Satisfactory Hydro test on #1 thermal fluid heater.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 5 June 2024
Resolution: Hydro was completed after 6" pipe nipple was removed and resealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2024 Resolved
Install electrical isolation mat infront of E-Gen switch board.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 8 June 2024
Resolution: New matting was installed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 June 2024 Resolved
Install break rods in all missing fire pull stations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2024
Resolved 10 June 2024
Resolution: Vessel installed new break rods.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 October 2022 Resolved
Power operated main and auxiliary steering gear must be of adequate strength for and capable of steering the vessel at maximum ahead service speed. The vessel's number 1 steering ram has been sheered off, rendering the steering gear inoperable. Once repaired, a satisfactory steering test must be completed in the attendance of a Coast Guard marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2022
Resolved 21 October 2022
Resolution: Steering ram was replaced, damaged linkage was replaced, and hydraulic relief valves were readjusted. Successful dock and sea trials were completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2022 Resolved
Provide root cause analysis for loss of propulsion on 15Jun and prove proper operation prior to the carriage of passengers. 46 CFR 62.25-1
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2022
Resolution: Replaced fuse. Conducted sea trials with no issues.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 April 2022 Resolved
Vital systems that are automatically or remotely controlled must be provided with an alarm system. Vessel self-reported that Omni-Chief user interface for alarm and monitoring system was not functioning as designed. Vessel must ensure that ECR is continuously manned while additional safety round of machinery space is completed when Omni-Chief user interface is rebooting. Vessel is to notify Sector Puget Sound Duty Marine Inspector of any further malfunctions or developments. 705C , 46 CFR 62.25-1
Action required: 705 - Other - as specified
Due 10 April 2022
Resolved 13 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2022 No resolution recorded
Submit a qualitative failure analysis to indicate automation assumptions, vessel/equipment, operating conditions, failures considered, cause and effect relationships, method of crew detection of failure and alternatives available to the crew of the ship's service and emergency switching gear. Provide a corrective action for any single point failures (non-concurrent) identified, updated and submit the required plans for approval with in 60 days. Any modifications or equipment replacement needed to effect the corrective actions shall be carried out at the vessel's next dry dock and demonstrated via design verification tests to the satisfaction of the attending Marine Inspector. Dry dock: Chetzemoka - 31Mar2023 Salish - 28Feb2024 Kennewick - 31Mar2025
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 December 2021 Resolved
Hold back devices were observed on the crew stair tower doors in the deck crew accommodations and in the engineering accommodation spaces. Hold back hooks, or other means of permanently holding these doors open, not subject to control station release, are not permitted. Remove installed hold backs from stair tower doors. 46 CFR 72.05-25(b)(9)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 February 2022
Resolution: No holdbacks observed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2021 Resolved
Vessel must have duplicate means of propulsion. #2 main engine is non operational. Complete repairs to #2 main engine
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2021
Resolution: Engine repaired. Cause was a loose wire
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 November 2020 Resolved
Fire screen door #17 will not close unassisted. Carryout maintenance needed for door to closed unassisted. This door is to remain closed until such time that it can be repaired and fucntions as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2020
Resolved 4 January 2021
Resolution: Received report from Eagle Harbor maintenance department that the door had been serviced and is working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2020 Resolved
#2 Aux heating boiler past due for hydro. Make boiler ready for hydrostatic test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2020
Resolved 18 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 November 2019 Resolved
All doors, except those that are kept normally closed, shall be of a type which are capable of release from the control sation and from a position at the door. The release mechanism shall be designed that the dor will automatically close in the event of disruption of the control system. Fire screen door number 8 did not properly close.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2019
Resolved 12 November 2019
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 12 November 2019 Resolved
Each space used by passengers or crew must be fitted with lighting that provides for a safet habitable and working environment under normal conditions. Total of 5 lights were out throughout the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2019
Resolved 26 February 2020
Resolution: Inspected all light fixtures, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 April 2019 Resolved
Vessel is required to have 100% lifesaving evenly distributed on each side of the vessel. Vessel reported that one of four IBA's launching equipment was damaged. The vessel shall only carry 50% of the total person capacity at 380 persons including crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 10 May 2019
Resolution: Received report from Puget Sound Inflatables for repairs to the launching appliances.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2019 Resolved
Provide a contact maker to positively transfer steering control to remedy partial steering transfers between the No. 1 and No.2 pilot house.
Condition: Design Flaw
Due 12 March 2019
Resolved 18 March 2021
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 29 January 2019 Resolved
M/E #2 loss of primary power audible and visual alarms failed to activate. Automatic transfer to required backup or redundant systems or power sources must be alarmed in the machinery spaces.
Action required: 10 - Deficiency Rectified
Resolved 29 January 2019
Resolution: Alarm system corrected by Eagle Harbor electrical shop.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 January 2019 Resolved
Instructions shall be posted in the steering room steps to be taken in changing to the emergency steering. No. 2 end operating instructions in steering gear room illegible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 23 April 2019
Resolution: Verified instructions posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2019 Resolved
Valve failure in potable water heating system prevented required hydrostatic testing of vessel auxiliary boilers. Repair or modify system to make ready for hydrostatic testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 18 March 2019
Resolution: All butterfly valves replaced, good hydrostatic boiler test completed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 January 2019 Resolved
First aid kit has expired items. Renew appropriate items to make ready for immediate use.
Action required: 10 - Deficiency Rectified
Resolved 29 January 2019
Resolution: First aid kits supplied by Eagle Harbor, all expired items removed from vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 January 2019 Resolved
Watertight door #4 did not indicate closed position in pilot house during remote test. Remote closure must activate and show whether the door is open or closed.
Action required: 10 - Deficiency Rectified
Resolved 29 January 2019
Resolution: Door closure device was lubricated and allowed final closure detector to read the door as closed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 January 2019 Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. Lifebuoys were faded and deteriorated and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2019
Resolved 29 January 2019
Resolution: Replaced with new life bouy.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 January 2019 Resolved
Each fire hydrant must have a at lest one lenth of fire hose, a spanner, and a hose rack or other device for stowning the hose. Fire station 13 hose unservicable and unable to combat fire.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2019
Resolved 29 January 2019
Resolution: Removed from service and replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 November 2018 Resolved
Vessel experienced loss of steering using A system, pumps 1A and 2A. Make necessary repairs to the steering system and prove proper operation. 46 CFR 58.25
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2018
Resolved 12 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 November 2018 Resolved
Install data logger on propulsion control/steering gear along with steering gear gauges to provide data. 46 CFR 71.25-50
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 26 February 2020
Resolution: Data logger installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 November 2018 Resolved
Provide non destructive testing of welds in way of damage from grounding. 46 CFR 72.01-15
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2018
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 November 2018 Resolved
Each vessel must have a steering failure alarm that actuates an audible and visible alarm in the pilot house when the actual position of the rudder differs more than 5 degrees from rudder position ordered by the follow up controls. In cruising mode the rudder lever was in the port 10 degrees position and no alarm was activated
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2018
Resolved 6 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 November 2018 Resolved
Markings in the pilothouse must not interfere with the helmsman's vision, but must be clearly visible at night, does not have illumination to read lever position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2018
Resolved 26 February 2020
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 September 2018 Resolved
#2 END Rudder is jammed to STBD as a result of a soft grounding. Damage to Rudder post must be repaired and sea trials conducted prior to carrying pax.
Condition: Damaged By Earlier Event
Due 16 November 2018
Resolved 9 November 2018
Resolution: All repairs completed, sea trials successful.
Personnel › Training › Familiarization Training
Issued 15 May 2018 Resolved
WHILE CONDUCTING FIRE DRILL NO CREW MEMBER CLEARED OR SIMULATED CLEARING PASSENGERS FROM THE AFFECTED SPACE AS ASSIGNED BY THE MUSTER LIST. UPON FURTHER REVIEW THE ONLY CREW MEMBER ASSIGNED TO PASSENGER CONTROL STOPPED AT THE FIRE DOOR BECAUSE THE DORRS WERE CLOSED BEFORE THEY GOT ON SCENE TO REMOVE PASSENGERS AND CREW MEMBER DID NOT KNOW TO BREECH THE SMOKE BOUNDARY TO COMPLETE ASSIGNED DUTIES. ALL CREW MEMBERS SHOULD RECEIVE TRAINING ENSURING THAT EMERGENCY POSITIONS ARE KNOWN BEFORE EACH CREW CHANGE. TITLE 46 CFR 199.180(b)(1) REQUIRES THAT EVERY CREW MEMBER WITH EMERGENCY DUTIES ASSIGNED ON THE MUSTER LIST MUST MUST BE FAMILIAR WITH THEIR ASSIGNED DUTIES BEFORE THE VOYAGE BEGINS. A REPORT SHALL BE SUBMITTED WHEN TRAINING IS COMPLETE FOR ALL CREW MEMBERS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2018
Resolved 29 January 2019
Operations/Management › Drills/Instruction › Fire
Issued 15 May 2018 Resolved
DURING DRILL IT WAS NOTED THAT THE VESSEL EMERGENCY RESPONSE PLAN WAS INEFFECTIVE IN COMMUNICATING EMERGENCY INSTRUCTIONS TO PASSENGERS AS REQUIRED BY 46 CFR 199.80. VESSEL LARGELY RELIES ON SYSTEM OF AMBER BEACONS ACTIVATED BY THE BRIDGE TO INFORM PASSENGERS OF PROPER PATH TO EMERGENCY MUSTER STATIONS, CREW MEMBERS WERE ABSENT DURING DRILL TO PROVIDE DIRECT INSTRUCTIONS. THE LIGHTS DO NOT CLEARLY INDICATE THE SAFE PATH TO THE MUSTER STATION, AS THERE IS LITTLE OR NO EXPLANATORY SIGNAGE ABOARD. AS PER THE MUSTER LIST, THERE IS ONLY ONE MEMBER OF THE CREW ASSIGNED TO CLEAR THE UPPER AND MAIN PASSENGER DECKS OF PASSENGERS IN AN EMERGENCY. THE DESIGNATED CREW MEMBER WAS ABSENT DURING DRILL. VESSEL PLAN MUST BE REVIEWED TO IMPROVE COMMUNICATIONS AND ENSURE THAT THERE IS SUFFICENT TRAINED MANPOWER TO EFFECTIVELY GUIDE PASSENGERS AWAY FROM DANGEROUS SITUATIONS AND DIRECT THEM TO MUSTER STATIONS. IMPLEMENTATION AND DEMONSTRATION OF THIS PLAN MUST BE PRESENTED TO THE SATISFACTIONS OF THE [name withheld] 90 DAYS.
Action required: 705 - Other - as specified
Due 1 October 2018
Resolved 29 January 2019
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 11 May 2017 Resolved
Prove proper operation of low water fuel cutoff device on boiler #1 and boiler #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 13 February 2018
Resolution: RESOLVED AT TIME OF COI INSPECTION
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 11 May 2017 Resolved
Service pressure/temperature gauge on boiler #1 and boiler #2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 13 February 2018
Resolution: RESOLVED AT TIME OF COI INSPECTION
Lifesaving › Inflatable Liferafts › Servicing
Issued 2 February 2017 Resolved
Operational deployment of slide #1 and #2 MES is extended until scheduled laid-up period, not to extend beyond 30APR17. 46 CFR 199.190(k)
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 1 May 2017
Resolution: slide deployed, reflects on COI
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 1 February 2017 Resolved
INSTALL COMPLETE BUT SIMPLE INSTRUCTIONS FOR OPERATION OF EDG CO2 SYSTEM IN A CONSPICUOUS PLACE AT OR NEAR ALL PULL BOXES, STOP VALVE CONTROLS, AND IN THE CO2 CYLINDER STORAGE ROOM. ALSO INCLUDE A SCHEMATIC DIAGRAM OF THE SYSTEM AND INSTRUCTIONS FOR DETAILING ALTERNATIVE METHODS OF DISCHARGING THE SYSTEM SHOULD THE MANUAL RELEASE OR STOP CHECK VALVES FAIL TO OPERATE. 46 CFR 76.15-10(h)
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 9 March 2017
Resolution: Rec'd pictures from PE Bob Pace with req'd key box, op instructions.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 1 February 2017 Resolved
INSTALL CONSPICUOUSLY LOCATED KEY, IN GLASS- BREAK- TYPE BOX, NEAR EDG CO2 ROOM SINCE SPACE REMAINS LOCKED. 46 CFR 76.15-10(i)
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 9 March 2017
Resolution: Rec'd pictures from PE Bob Pace with req'd key box, op instructions.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 August 2016 Resolved
Remove salt bag broken on deck #2 end. Clean off steel deck. 04AUG
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 4 August 2016
Resolution: Deck crew cleaned up bag of salt.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 4 August 2016 Resolved
Provide and place onboard copy of NTVRP letter.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 10 August 2016
Resolution: NTVRP letter onboard.
Stability › Weathertight Integrity › General
Issued 4 August 2016 Resolved
Properly repair gasket on weathertight door #2 end port side.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 10 August 2016
Resolution: Gasket was replaced.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 4 August 2016 Resolved
Provide copy of liferaft servicing certificates for IBAs.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 10 August 2016
Resolution: LSA Servicing certs on board.
Engineering › Steering Gear System › Pin
Issued 9 June 2016 Resolved
Pin discovered broken on #1 end. Replace boken pin.
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Pin was replaced, sea trials performed, inspector observed operational checks.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 May 2016 Resolved
Radar on #1 end inoperable. 46 CFR 77.09-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2016
Resolution: Radar power source updated.
Lifesaving › Lifebuoys › Serviceable
Issued 3 May 2016 Resolved
New retro reflective tape on Texas deck life ring buoys where faded. 46 CFR 199.70(a)
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 5 May 2016
Resolution: New retro added
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 3 May 2016 Resolved
Various power supply units for vital system automation are in a ground fault condition. Provide approved plans to OCMI for repair oversight. 46 CFR 62.20
Action required: 705 - Other - as specified
Due 3 September 2016
Resolved 28 December 2016
Resolution: Approved plans have been provided for the segregation of the electrical panels at the #1&#2 end as well as the emergency generator 24VDC power supply system. Witnessed testing of the ground fault dection. All SAT.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 3 May 2016 Resolved
Provide audible and visual EOT power failure alarm in both pilot houses. 46 CFR 113.35-5(e)(2)
Action required: 705 - Other - as specified
Due 3 September 2016
Resolved 28 December 2016
Resolution: Witnessed EOT audible and visual alarm at #1&#2 End, Main Control in engineroom. All SAT.
Engineering › Steering Gear System › Rudder
Issued 29 February 2016 Resolved
#2 end flip rudder neck bearing and bushing show visible signs of accelerated wear causing flip rudder contact main rudder during turns. Provide rudder vendor recommendation for short and long term repairs/monitoring for Coast Guard approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2016
Engineering › Steering Gear System › Rudder
Issued 29 February 2016 Resolved
#2 End flip rudder neck bearing was found with accelerated wear during UWILD. Make permanent repairs to rudder and bearing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2016
Resolution: Rudder fixed. Sea trials conducted. All sat.

Casualty record · 14

17 September 2011Routine · role: Involved in a Marine Casualty · activity 4150720
21 November 2012Routine · role: Involved in a Marine Casualty · activity 4492140
11 February 2013Routine · role: Involved in a Marine Casualty · activity 4552267
3 March 2013Routine · role: Involved in a Marine Casualty · activity 4544068
24 May 2013Routine · role: Involved in a Marine Casualty · activity 4606742
8 October 2013Routine · role: Involved in a Marine Casualty · activity 4733293
21 November 2013Routine · role: Involved in a Marine Casualty · activity 4757185
8 August 2017Routine · role: Involved in a Marine Casualty · activity 6234566
9 September 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6549517
30 November 2018Routine · role: Involved in a Marine Casualty · activity 6870563
30 May 2021Routine · role: Involved in a Marine Casualty · activity 7210436
6 June 2021Routine · role: Involved in a Marine Casualty · activity 7220335
15 June 2022Routine · role: Involved in a Marine Casualty · activity 7480303
20 October 2022Routine · role: Involved in a Marine Casualty · activity 7581407
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.