KENNEWICK

KENNEWICK is a 2011 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 2016, most recently in July 2026, along with 55 deficiencies and 12 casualty investigations between 2012 and 2018.

Records from 2012 to 2026. Most recent: inspection, 7 July 2026.

Built
2011
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 July 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF6991
1046775
Flag
UNITED STATES
Maury page id
psix-1046775

Documentation record

Registered dimensions (L × B × D)257.4 ft × 64.0 ft × 17.6 ft
Registered tonnagegross 4,623 / net 1,887
ITC dimensions (L × B × D)257.4 ft × 64.0 ft × 17.6 ft
ITC tonnagegross 4,623 / net 1,887
BuilderVIGOR SHIPYARDS · SEATTLE, WA, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4623 - Convention (Subpart B), Gross Ton
1887 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 68

7 July 2026 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8432592
13 April 2026 Deficiency Check · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8347300
5 March 2026 Administrative Inspection · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8320719
27 February 2026 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8317750
17 December 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8284921
30 October 2025 COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8260454
25 August 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8218141
28 April 2025 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8123579
8 January 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8059842
6 December 2024 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8012477
20 September 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8006508
22 July 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7964638
26 June 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7943226
1 April 2024 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7888343
28 November 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7829151
6 November 2023 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7821661
21 June 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7719840
13 June 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7713866
6 May 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7747471
27 April 2023 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7677074
31 March 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7660224
21 January 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7624933
22 December 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7612153
19 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538444
16 August 2022 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7547572
9 June 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7473891
19 April 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7433499
10 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7409735
8 February 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7393797
29 December 2021 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7373534
3 July 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7244124
21 June 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7232563
3 March 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7150563
7 December 2020 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7120220
19 November 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7098226
15 September 2020 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7059144
28 May 2020 Underwater Inspection in lieu of Drydock · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6963110
26 March 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6931899
24 February 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6914968
22 January 2020 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6894597
9 January 2020 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6872253
11 December 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6873533
16 September 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6782672
5 April 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6655368
26 March 2019 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685689
20 December 2018 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6597990
11 December 2018 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6596225
11 December 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6597540
21 November 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6585120
26 September 2018 Administrative Inspection · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6535804
5 September 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6555292
23 July 2018 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6488299
11 April 2018 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6391281
30 November 2017 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6310855
4 October 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6280823
8 September 2017 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6262873
2 June 2017 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6168472
19 April 2017 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6128107
19 April 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6152564
16 March 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6112314
3 February 2017 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6089971
16 December 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6065806
10 November 2016 Administrative Inspection · COI Inspection · Underwater Inspection in lieu of Drydock · Internal Structural Exam · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6019940
20 October 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6026241
14 July 2016 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5946017
1 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5917688
14 April 2016 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5854383
11 January 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5795176

Deficiency record · 55

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2026 Resolved
Creation of a crew area in the mezzanine lounge has changed a public access area that includes Passenger assembly area 2 to an employee access area. This change may conflict with certain approved plans/drawings (e.g. Fire and Safety, Lifesaving arrangement,Compliance Signage/Assembly, etc.). If this arrangement is to be retained submit a detailed plan to the OCMI for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2026
Resolved 12 August 2026
Resolution: WSF has removed the ad hoc crew area restoring the configuration as found on approved plans.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 5 March 2026 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Vessel reported abnormality with pitch controller and unable to proceed faster than 50% pitch. Vessel to repair to the satisfaction of the attending marine inspector prior to carrying passengers. 46 CFR 71.40-1
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2026
Resolved 6 March 2026
Resolution: Crew replaced the pitch controller board.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 October 2025 Resolved
The following emergency lighting and power loads must be arranged: Illuminated signs with the word "EXIT" in red letters throughout a passenger vessel so the direction of escape to the open deck is obvious from any portion of the vessel usually accessible to passengers and crew, except machinery spaces, and except stores and similar spaces where the crew are not normally employed. Photo-luminescent "EXIT" signs throughout the vessel are marked "Replace before Oct 2025" on the manufacturer's label, and have lost their photo-luminescent properties.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 27 February 2026
Resolution: New signs purchased and installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 October 2025 Resolved
The following emergency lighting and power loads must be arranged: lighting...for damage control lockers. Battery powered e-light EP201-8 in emergency squad locker on the passenger deck is not illuminating properly when tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 3 November 2025
Resolution: Battery has been replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 October 2025 Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting off the passage of air in the event of fire. Multiple manually operated dampers on deckhouse exterior with bolts/wing nuts and hand levers found with hardware seized, preventing proper actuation. Replace hardware to make properly usable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 3 November 2025
Resolution: Seized wing nuts replaced with stainless steel ones, added never-seize, and dampers operated to verify free movement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2025 Resolved
Each panelboard must have a circuit directory that has the circuit designation of each circuit, a description of the load of each circuit, and the rating or setting of the overcurrent protection device for each circuit. Breaker panels P201 and P202 in pilothouse #1 and #2, respectively, have circuit 1 labeled as 15A circuit for coffee maker and circuit 3 as 20A circuit for hot/cold water dispenser. However, both breaker panels actually have a 20A circuit breaker on circuit 1 and a 15A circuit breaker on circuit 2. Determine correct breaker settings and circuit panel directory labels and correct necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 3 November 2025
Resolution: Confirmed that 20A breakers have the correct wiring. Circuit directory cards in the panel doors updated to show circuit 1 as 20A and circuit 2 as 15A.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 30 October 2025 Resolved
All general alarm bells shall be identified by red lettering at least 1/2 inch high: "GENERAL ALARM - WHEN BELLS RINGS GO TO YOUR STATION". General alarm bell in #2 end reduction gear room, near the hi-fog skid, is missing its label. Additionally, the rotating red general alarm light in the center of the #2 end reduction gear room is also missing its label.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2025
Resolved 3 November 2025
Resolution: Placard added for #2 reduction gear room GA bell and roatting beacon. Port engineer also added lables for rotating beacons in #1 reduction gear room, aux shop, and ME room.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 August 2025 Resolved
Each elevator on a vessel must meet the requirements of ANSI A 17.1. Passenger and freight elevators displayed expired annual operating certificates in the elevator cars.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2025
Resolved 27 August 2025
Resolution: Updated elevator annual operating certificate posted in passenger adn freight elevators with a new expiry of 01JAN2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2025 Resolved
..all lifejacket containers must be marked in block capital letters with minimum quantity...size of the lifejackets stowed inside the container. Lifejacket stowage bin located in passenger assembly station on no. 1 end of mezzanine level was missing its wall-mounted placards indicating lifejackets and quantities.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2025
Resolved 27 August 2025
Resolution: A temporary placard with lifejacket inventory was posted above the lifejacket bin in the passenger assembly station.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 August 2025 Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. Two compressed gas cylinders in the No. 1 end tank room were stowed without caps and regulators installed.
Action required: 10 - Deficiency Rectified
Due 25 August 2025
Resolved 25 August 2025
Resolution: Caps installed prior to inspection completion.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 January 2025 Resolved
Fire Station 15 nozzle found leaking at handle.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2025
Resolved 8 January 2025
Resolution: Provided renewed nozzle. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 January 2025 Resolved
Fire station 10 nozzle found leaking at the handle.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2025
Resolved 8 January 2025
Resolution: Provided renewed nozzle. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 January 2025 Resolved
Fire station 12 nozzle found leaking at the handle.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2025
Resolved 8 January 2025
Resolution: Provided renewed nozzle. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 January 2025 Resolved
Fire station 11 hose found leaking at fitting.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2025
Resolved 8 January 2025
Resolution: Ship's crew cut old hose and provided new 50 foot length of hose to be placed in service.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 January 2025 Resolved
Found sprinkler head worn requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2025
Resolved 8 January 2025
Resolution: WSF replaced worn sprinkler head with a renewed item. Test sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2024 Resolved
Biobore locker N0.1 end not rated UL30 or UL 1313. Provide proper storage locker or relocate flammable ships stores to an appropriate location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 26 June 2024
Resolution: Chief Engineer had material moved to an appropriate location.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 June 2024 Resolved
Class three water tight door in the engine room does not have an audible warning signal when operated remotely. Provide controls IAW ASTM F 1197-11.5.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 20 September 2024
Resolution: Item verified at this inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 January 2023 Resolved
The prime mover of a generator set must have all accessories necessary for operation and protection of the prime mover. Block heater for the emergency generator is not operational. Provide proof of repair of inoperable block heater to marine inspector. Cite: 46CFR112.50-1(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2023
Resolved 21 January 2023
Resolution: Received email that stated the inoperable block heater had been replaced.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 5 January 2023 Resolved
Periodic safety tests must be conducted on alarms and safety control for maneuvering systems. Vessel does not currently have test procedure for low lube oil on the steering sumps. Submit plans for review to incorporate this requirement to the Marine Safety Center within 60 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 March 2023
Resolved 30 March 2023
Resolution: Updated procedure has been submitted to MSC for approval.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2022 Resolved
An inspection, either general or partial depending on the circumstances, shall be made whenever any important repairs or alterations are undertaken. Significant pitting in stern tubes on ends #1 & 2 requires repair/replacement and re-installation of the propulsion shafts. Repair/replace to the satisfaction of the attending marine inspector. 46 CFR 71.55-5
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2022
Resolved 25 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2022 Resolved
An inspection, either general or partial depending on the circumstances, shall be made whenever any important repairs or alterations are undertaken. Due to drydock availability, the rudders and port side keel cooler were not able to be put back on prior to leaving drydock. Reinstall rudders and keel cooler to the satisfaction of the attending marine inspector. 46 CFR 71.55-5
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2022
Resolved 24 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2022 Resolved
Submit a qualitative failure analysis to indicate automation assumptions, vessel/equipment, operating conditions, failures considered, cause and effect relationships, method of crew detection of failure and alternatives available to the crew of the ship's service and emergency switching gear. Provide a corrective action for any single point failures (non-concurrent) identified, updated and submit the required plans for approval with in 60 days. Any modifications or equipment replacement needed to effect the corrective actions shall be carried out at the vessel's next dry dock and demonstrated via design verification tests to the satisfaction of the attending Marine Inspector. Dry dock: Chetzemoka - 31Mar2023 Salish - 28Feb2024 Kennewick - 31Mar2025
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 17 June 2025
Resolution: This def was cleared on 9JAN2025 by [name withheld] but was not addressed in MISLE.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2021 Resolved
Vessel reported malfunction in 2A circuit of No. 2 end steering system when transferring from transit to maneuvering mode, resulting in deviation on rudder angle indicator by 6 degrees. Although steering system is back and operational, vessel is required to replace connections on terminal strips for 2A circuit of the No. 2 end. Until then, vessel required to have both shafts engaged for steering redundancy.
Action required: 10 - Deficiency Rectified
Due 17 July 2021
Resolved 6 July 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 January 2021 Resolved
A single non-concurrent failure in a control system must not prevent sustain operation of a vital system. A failure of the EDG control system resulted in the opening of the emergency bus tie breaker rendering the emergency power supply system in a dead bus condition, without means to energize emergency loads from either the main source or the emergency source. Provide an analysis and corrective action to ensure that the emergency bus tie breaker is capable of providing power to the emergency loads in the event that a failure in the EDG control system is sustained. If modifications are required they should be submitted to the USCG MSC for review and approval. 46 CFR 62.30-5(a), 112.05-1 & 5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2021
Resolved 17 June 2025
Resolution: This def was cleared on 9JAN2025 by [name withheld] but was not addressed in MISLE.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 3 December 2020 Resolved
During periodic safety testing of emergency generator, automatic transfer of emergency power load was unsuccessful. Demonstrate proper operation of automatic transfer of emergency power load IAW approved PSTP to satisfaction of an attending marine inspector. 46 CFR 112.20-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 December 2020 Resolved
Emergency instructions must include information on the essential actions they must take in and emergency, the location of life-jackets and donning instructions. The life jacket stowage release instructions were found to be faded and hard to read.
Action required: 10 - Deficiency Rectified
Due 17 December 2020
Resolved 7 December 2020
Resolution: New signage was posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2020 Resolved
Complete but simple instructions for the operation of the system must be located at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. The EDG's room (and CO2 bottles location) CO2 system's instructions did not depict a clear step by step picture on how to activate the system.
Action required: 10 - Deficiency Rectified
Due 17 December 2020
Resolved 4 January 2021
Resolution: New signage was posted locally at the E-GEN CO2 bottles.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2020 Resolved
Where natural ventilation is provided for spaces protected by CO2 extinguishing systems, provisions shall be made for easily and effectively closing off the ventilation. The door leading to the EDG does not seal all the way around. The space is CO2 protected and requires a complete seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2020
Resolved 9 February 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 December 2020 Resolved
On vessels required by 46 CFR 112.05-5a to have temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source. Including low location, stairways and public spaces. A number of emergency lights were found burnt out.
Action required: 10 - Deficiency Rectified
Resolved 9 December 2020
Resolution: All e-lights were replaced and operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2020 Resolved
The inspection shall be such as to ensure all parts of the vessel and its equipment is in all respects satisfactory by applicable statutes and regulations. The vessel was updating its steering system an unable to provide a steering gear test. 01 outstanding deficiency (regarding this)from previous inspection remains open.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 January 2021
Resolution: DVTPs were completed and sea trials were completed on this date.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 September 2020 Resolved
Auxiliary heating boiler space has no semi-portable fire extinguisher. Space requires 1 160-B(old B-V) extinguisher IAW Table 76.50-10(a).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 3 December 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 9 January 2020 Resolved
Provide documentaiton for annual reviews of vessel reposnse plan. 33 CFR 155.5070(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 3 December 2020
Resolution: Completed annual review.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 January 2020 Resolved
Lifejackets on bridges were not properly marked and missing IMO symbol. 46 CFR 199.178 (a) and (b)
Action required: 10 - Deficiency Rectified
Resolved 9 January 2020
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 January 2020 Resolved
Lifejackets in accommodation spaces were not properly marked and missing IMO symbol. 46 CFR 199.178 (a) and (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 3 December 2020
Resolution: all life jackets were properly posted.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 9 January 2020 Resolved
The maintenance of the rescue boats wire ropes are not maintained in accordance with manufacturers instructions. See Welin Lamnie Technical Manual Section 4.5. 46 CFR 199.190(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 3 December 2020
Resolution: Rescue boat is being properly maintained.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020 Resolved
All automatically or remotely controlled or monitored vital systems must be subjected to test inspections. Test procedures must be submitted and approved by the Coast Guard Rev. 0 and Rev. 1. No test procedures listed for emergency generator, low lube oil pressure, overspeed trip, and for high cooling water temperature.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 2 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2018 Resolved
Replace Hot Water heating boilers supply and return valves. They do not stop water.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 March 2019
Resolved 5 April 2019
Resolution: Verified new gates valves have been installed, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 December 2018 Resolved
Installed CO2 time delay in the emergency generator fixed CO2 system did not function as designed, delaying the release well over the designed 30 seconds. Replace and test new time delay. Until a new time delay is installed the directional control valve shall be left open as if the time delay already activated the valve, to ensure that the space can be flooded with CO2. A notice on the emergency generator room and at the CO2 controls shall inform the crew that the time delay is currently bypassed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2019
Resolved 7 January 2019
Resolution: Port Engineer submitted video of the operation of time delay releasing in under 30 seconds.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 21 November 2018 Resolved
If a lever type control is provided, it must be installed and marked so that its movement clearly indicates both the direction of the rudders movement, and if follow up control is provided, the amount of rudder movement, current arrangement has no markings on opposing helm levers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 5 April 2019
Resolution: Appropriate markings installed properly displaying direction and amount of rudder movement.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 21 November 2018 Resolved
Each vessel must have a steering failure alarm that actuates an audible and visible alarm in the pilot house when the actual position of the rudder differs more than 5 degrees from rudder position ordered by the follow up controls. In cruising mode the rudder lever was in the port 10 degrees position and no alarm was activated
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 21 December 2018
Resolution: Tested the deviation alarm. Worked as designed when the PLC was in control of the steering.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 21 November 2018 Resolved
Markings in the pilothouse must not interfere with the helmsman's vision, but must be clearly visible at night, does not have illumination to read lever position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 5 April 2019
Resolution: Proper illumination of operating station confirmed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2018 Resolved
Vessel's steering system has been found to be capable of indicating control in both pilot houses if the transfer of control button is not fully pressed in. While indication of control is illuminated at both helm stations each helm has partial to no control of steering. Vessel is authorized to continue operation provided they implement a mitigation plan. The plan shall require the master and chief mate to provide positive confirmation of a complete transfer of control by indication of the green in command light and red not in command light on either end. After positive confirmation, the in command helm shall test both bow and stern rudders to verify command prior to leaving the dock of each crossing. In addition an AB or the mate shall remain in the not in command pilot house to verify that command is never indicated or alarms activated. The mitigation plan shall remain in effect till such a time that the steering systems have been proven to be in satisfactory compliance.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 9 February 2021
Resolution: Extended from 12/31/2020 to new date to allow for final MSC review of DVTP for steering. See Act 7120220 for further details.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 September 2018 Resolved
Complete but simple instructions for the operation of firefighting systems must be located at each control station. CO2 and high fog remote and local operating stations were not marked. During the fire drill the crew demonstrated a lack of CO2 system operation. Provide instructions at the location of each control.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 3 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2018 Resolved
Indicate the number of lifejackets in each stowage location. Port side mezzanine was previously marked with tape that has since been removed. Mark location with accurate number of lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2018
Resolved 3 December 2018
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 July 2018 Resolved
N. 1 end, stbd side mezzanine door found propped open with chock. (FSD #5)
Action required: 10 - Deficiency Rectified
Due 23 July 2018
Resolved 23 July 2018
Resolution: Removed Chock. Corrected on the spot.
Communications › Alarms/Indicators › General Alarm
Issued 30 November 2017 Resolved
03 Strobe lights emitted insufficient lighting/visual indication of general alarm in STBD FWD ENG RM (1) and in #1 RED GEAR RM (2).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2018
Resolved 11 April 2018
Resolution: Installed larger strobe units with brighter output adjacent to existing units.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 30 November 2017 Resolved
Compass deviation card has not been updated since 2011.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 December 2017
Resolved 13 December 2017
Resolution: Compass deviation card was updated on 12 DEC 2017, proof of updated card was satisfactorily provided to attending Marine Inspector.
Engineering › Steering Gear System › Follow-up Assembly
Issued 30 November 2017 Resolved
NFU mode for Steering Gear Pumps on #1 END not indicating proper helm arrangement. In NFU mode, rudder indicates port when positioned to starboard, and starboard when positioned to port.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2017
Resolved 30 November 2017
Resolution: Wires had been mistakenly switched when regular maintenance has recently occured. Vessel representative provided satisfactory proof that the No 1 END steering worked in all modes.
Engineering › Steering Gear System › Power Unit
Issued 30 November 2017 Resolved
Steering gear not provided with power disconnect in the steering gear space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 July 2018
Resolved 9 January 2020
Resolution: Verified power disonnect in the steering gear space.
Communications › Alarms/Indicators › Propeller Pitch Position Indicator
Issued 30 November 2017 Resolved
Remote Propulsion Control in both pilot houses has no audible alarm upon failure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 8 March 2018
Resolution: Alarms provided in each wheelhouse A&M system.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 30 November 2017 Resolved
Repairs to correct persistent power supply ground fault not as depicted in approved plan. Provide "as built" details that differ from approved plan for approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 4 March 2018
Resolution: Plans corrected to as built.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 December 2016 Resolved
UPDATE FIRE CONTROL PLAN. SUBMIT NEW PLAN TO U.S.C.G SECTOR PUGET SOUND FOR APPROVAL. 46 CFR 71.65-5(d)
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 13 January 2017
Resolution: SPS received new FCP this date. Will verify contents on 03FEB17 during quarterly. [name withheld]
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 10 November 2016 Resolved
#1 Main Engine did not shut down when the E-stop button in the #1 Pilothouse was activated. Demonstrate proper function to the attending USCG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2016
Resolved 28 November 2016
Resolution: Repaired loose wire on main engine. Started and shutdown #1 engine from emergency shutdown button in #1 Pilothouse. Ops check good.
Lifesaving › Launching Appliances › Davit
Issued 10 November 2016 Resolved
#1 Rescue Boat requires dynamic brake test due to bridle modifications.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2016
Resolved 16 November 2016
Resolution: Witnessed dynamic weight test with 110% of max weight onboard.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 20 October 2016 Resolved
Crew must complete manual draft readings twice daily (beginning & end of operations). Additionally, if any unusual listing occurs crew must complete manual draft readings to ensure vessel is within correct range IAW vessel stability letter. Manual readings shall continue until system is functioning as intended.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 4 May 2017
Resolution: Failed sensors replace, unit calibrated, and tested sat.

Casualty record · 12

27 July 2012Routine · role: Involved in a Marine Casualty · activity 4395598
9 December 2012Routine · role: Involved in a Marine Casualty · activity 4723766
18 December 2012Routine · role: Involved in a Marine Casualty · activity 4507793
13 April 2013Routine · role: Involved in a Marine Casualty · activity 4569238
28 January 2014Routine · role: Involved in a Marine Casualty · activity 4791264
3 March 2014Routine · role: Involved in a Marine Casualty · activity 4809873
5 March 2014Routine · role: Involved in a Marine Casualty · activity 4810776
30 April 2015Routine · role: Involved in a Marine Casualty · activity 5115102
14 June 2015Routine · role: Involved in a Marine Casualty · activity 5155109
1 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5917688
16 March 2017Routine · role: Involved in a Marine Casualty · 1 injured · activity 6112314
5 September 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6555292
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.