MAURY USCG vessel records
← All vessels

LIBERTY

Built
2012
Last inspected
4 June 2025
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 4 June 2025
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2012–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9601821
WDG3575
1047215
Flag
UNITED STATES
Tonnage
1567 - Regulatory (Subpart C or D), Gross Ton 2164 - Convention (Subpart B), Gross Ton 1066 - Regulatory (Subpart C or D), Net Ton 649 - Convention (Subpart B), Net Ton
Maury page id
psix-1047215
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

4 June 2025 Re-Inspection · ACP COI Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8123461
9 April 2025 TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8108846
21 October 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8022264
18 October 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8021098
17 June 2024 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7936977
5 July 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7733932
8 June 2023 ISM SMC Audit · ISM Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7710032
17 April 2022 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7452086
22 June 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7232810
23 April 2020 ACP COI Oversight · MTSA/ISPS Verification · Re-Inspection · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6942910
6 October 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6829844
6 May 2019 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6674670
1 February 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6618594
14 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6512327
11 April 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6385718
17 July 2017 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6208635
26 June 2017 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6187495
29 July 2016 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5957078
5 May 2015 Periodic Inspection · Drydock Exam · Internal Structural Exam · MTSA/ISPS Verification · Deficiency Check · ACP Handover Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5118169
24 March 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5089681
22 July 2014 Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4926341
27 August 2013 Annual Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4760432
8 June 2012 MTSA/ISPS Verification · Initial Certification · MARPOL Annex V Examination · MARPOL Annex IV Survey · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4304791

Deficiency record · 7

10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 1 February 2019 Resolved
All ships of 500 GT ITC and upwards shall have a gyro-compass bearing repeater, or other means, to take bearings, over an arc of the horizion of 360 degrees, using the gyro-compass or other means referreed to above. ACP ACS to attest suitability of shipboard arrangement 74SOLAS(2009) V/19.2.5.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2019
Resolved 28 March 2019
Resolution: EQUIVALENCY LETTER ISSUED BY CVC, VESSEL MEETS EQUIVALENT SAFETY MEASURES. DEFICIENCY CLEARED.
Fire Fighting › Firemans Outfit › Quantity
Issued 1 August 2016 Resolved
Where more than one fire-fighter's outfit or more than one set of personal equipment is carried, they shall be stored in widely seperated positions. Both fire-fighter's outfits are located in the aft, port side emergency gear locker. 74SOLAS(2009) II-2/10.3.1.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 25 August 2016
Resolution: Received class report, cleared deficiency.
Lifesaving › Lifebuoys › Stowage
Issued 1 August 2016 Resolved
Not less than two lifebuoys, provided with lights and smoke, shall be capable of quick release from the navigational bridge. Brackets found broken and not capable of quick release as designed. ACP ACS to attest to proper operation and suitability of arrangement for releast to water. 74 SOLAS(2009) III/7.1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 25 August 2016
Resolution: Received class report, cleared deficiency.
Stability › Intact Stability (when using lifting gear) › General
Issued 1 August 2016 Resolved
The vessel's stability letter indicates it meets the stability requirements for Uninspected Towing Vessel in 46 CFR SubChapter C. Vessel is inspected IAW 46 CFR SubChapter I. ACP ACS to rectify and correct. 46 CFR 93.01*1
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 25 August 2016
Resolution: Received class report, cleared deficiency.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 1 August 2016 Resolved
All ships of 500 GT ITC and upwards shall have a gyro-compass bearing repeater, or other means, to take bearings, over an arc of the horizon of 360 degrees, using the gyro-compass or other means referred to above. ACP ACS to attest to suitability of shipboard arrangement. 74SOLAS(2009) V/19.2.5.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2018
Resolved 1 February 2019
Resolution: Extended for an additional 6 months.
Communications › Alarms/Indicators › General Alarm
Issued 1 August 2016 Resolved
The BNWAS motion sensor is blocked by an oscillating fan. Remove prior to operation and watchstanding. 74SOLAS(2009) V/19.2.23
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: Crew removed oscillating fan, cleared deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 15 May 2015 Resolved
Complete but simple instructions for the operation of the fixed CO2 systems must be onboard. The current instructions onboard are not correct because they do not allow for proper alarms/warnings for affected spaces prior to potential release of CO2. The vessel is to have updates instructions made and installed to replace the old instructions.
Action required: 705 - Other - as specified
Due 15 June 2015
Resolved 22 May 2015
Resolution: Received documentation, via digital photos e-mailed from the vessel, that updated placards/instructions were installed for operation of the vessel''s fixed CO2 fire-fighting system. All appeared satisfactory.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.