MAURY USCG vessel records
← All vessels

SELENKA

SELENKA is a 2009 tank ship. The Coast Guard has recorded 11 inspections since 2018, most recently in May 2026, along with 2 deficiencies.

Records from 2018 to 2026. Most recent: inspection, 26 May 2026.

Built
2009
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9447067
1047257
Flag
MALTA
Maury page id
psix-1047257

Documentation record

Tonnage as PSIX records it14807 - Displacement, Metric Ton
7260 - Convention (Subpart B), Gross Ton
3652 - Convention (Subpart B), Net Ton
10745 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

26 May 2026 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8373687
10 January 2026 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8292431
10 February 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8077613
23 January 2025 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8067446
18 July 2023 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7745669
10 July 2023 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7787040
9 July 2023 COC-CHEM Renew · PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7725438
13 February 2021 PSC B · COC-CHEM & TVE Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7137926
18 July 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6754102
16 July 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6747000
26 April 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6396229

Deficiency record · 2

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 16 July 2019 Resolved
The company should establish procedures, plans and instructions, including checklists as appriopriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment... The ship's Nitrogen inert gas system high oxygen alarm was set to 10%. The system should have procedures and alarm limits lested in crew's instructions. 74SOLAS(14)/IX/3.1; ISM code A/7 - 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 18 July 2019
Resolution: After reviewing attached correspondence and attestation from Class BV, deficiency cleared
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 July 2019 Resolved
When table 1 refers to this section or requires a cargo to have a closed gauging system, the cargo's containment system must have a high level alarm: that gives an audible and visual alarm before the tank fills to 97 percent of it's capacity... the vessel's 4 stbd tank high level and overfill alarms were switched so that the overfill alarm went off first. Electrician fixed. 33CFR153.409 - 10c
Action required: 10 - Deficiency Rectified
Resolved 16 July 2019
Resolution: The electrician was able to correct the deficiency during the exam.

Ownership record