Records from 2018 to 2026. Most recent: inspection, 5 July 2026.
Inspection history · 21
5 July 2026
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8429657
8 April 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8344736
27 February 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8317572
16 January 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8297569
5 December 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8278304
1 November 2025
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8256025
4 September 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8227154
26 July 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8195003
19 June 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8159247
13 February 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8079201
1 January 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8056479
24 November 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8033700
21 August 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7984891
15 January 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7849508
28 June 2023
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7719047
22 August 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7540592
9 August 2022
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7528874
31 January 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7129744
6 July 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6729453
19 January 2019
ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6612337
21 June 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6445794
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2024
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT. THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED TWO ELECTRICAL BREAKERS THAT WERE NOT INSTALLED TO SYSTEM RATING AND UNSAFE TO CREW.
74SOLAS (2) II-1/40.1.3
10C
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 24 November 2024
Resolved 24 November 2024
Resolution: Breakers replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2022
Resolved
All electrical applications shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed exposed electrical wiring to multiple fuel oil purifier motors.
74 SOLAS (14) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 22 August 2022
Resolution: Received class report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 August 2022
Resolved
The machinery boilers and other pressure vessels, associated piping systems and fittings ahsll be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed excessive fuel pooling on the bottom of the fuel injectors on #1,2,3 & 4 vessel generators.
74 SOLAS (14)II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2022
Resolved 22 August 2022
Resolution: Received class report attesting to repairs.