KAVIK WIND

KAVIK WIND is a 1970 towing vessel. The Coast Guard has recorded 13 inspections since 2006, most recently in August 2025, along with 8 deficiencies and 1 casualty investigation in 2011.

Records from 2006 to 2025. Most recent: inspection, 28 August 2025.

Built
1970
Last inspected
28 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 28 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2006–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM8863
104817
Flag
UNITED STATES
Maury page id
psix-104817

Documentation record

Registered dimensions (L × B × D)64.0 ft × 27.0 ft × 5.7 ft
Registered tonnagegross 105 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOLBERG, INC. · STOCKTON, CA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portANCHORAGE, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it105 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BARGE 210 Freight Barge · MISLE 46499 · 22 July 2011 · activity 4096335

Inspection history · 13

28 August 2025 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8210094
25 June 2024 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7932218
30 November 2023 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7832532
26 October 2023 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7824294
11 October 2022 Administrative Inspection · Special
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7575172
14 June 2021 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7250729
1 June 2020 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6966761
15 September 2015 MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5226301
8 May 2012 Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4780303
22 July 2011 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4096335
13 September 2010 Deficiency Check · Industry Initiated Exam · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3859235
7 September 2007 MTSA Verification
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3055577
21 November 2006 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2826392

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 June 2024 Resolved
The fuel shut-off valve must be installed in the fuel piping directly outside of the fuel oil supply tank. The remote fuel shut-off valves for the port and starboard fuel tank is not located directly outside the fuel tank, relocate remote shut-off valve directly outstide of the port and starboard fuel tanks. 46 CFR 143.260
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 5 September 2024
Resolution: Remote fuel shutoff valves installed outside of tank and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 June 2024 Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. The installed bilge system is not fitted with check/foot valves on the suction line, install check/foot valves on the bilge piping system. 46 CFR 143.275
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 23 August 2024
Resolution: Check valves installed on bilge piping system.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 25 June 2024 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard, or rail. The port main engine is missing a guard on the balancer and all shafts are don't have guards in place, place guards over rotating hazards. 46 CFR 144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 23 August 2024
Resolution: Machinery guards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 June 2024 Resolved
The following systems must be equipped with gauges at the machinery location: (1)Main engine RPM gauge;(3) Auxiliary engine oil pressure. The main engine did not have a RPM gauge and the auxiliary engine did not have a oil pressure gauge at machinery location, install gauges in machinery location. 46 CFR 143.230(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 23 August 2024
Resolution: Guages installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2024 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Alarm set points must be tested for main engine and auxiliary engine low lube oil pressure, high cooling water temp. There are no records of alarm set point tests being conducted for main engine or auxiliary engines. 46 CFR 143.245
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 5 September 2024
Resolution: Alarm set point tests conducted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 June 2024 Resolved
Each carbon dioxide or clean agent fire extinguishing alarm must be conspicuously marked: “WHEN ALARM SOUNDS VACATE AT ONCE. CARBON DIOXIDE OR CLEAN AGENT BEING RELEASED.”. The carbon dioxide system alarm is not marked, place notification marking near alarms. 46 CFR 136.110 46 CFR 78.47-9
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 23 August 2024
Resolution: Signage posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 June 2024 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (a) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.” (b) Spaces protected by carbon dioxide — “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” (c) Spaces into which carbon dioxide might migrate — “CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES VACATE IMMEDIATELY.” The fixed CO2 fire fighting system did not have warning signage posted at the entrance to spaces storing CO2, spaces protected by carbon dioxide, and spaces into which carbon dioxide might migrate. Place signed at entrances to spaces exposed to hazards of the fixed CO2 system. 46 CFR 136.110 46 CFR 78.47-11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 23 August 2024
Resolution: Singage posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 June 2024 Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a schematic diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. Place CO2 system operating instructions and schematic diagram of the system in the CO2 storage room. 46 CFR 136.110 46 CFR 76.15-10(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 5 September 2024
Resolution: CO2 system operating instructions posted.

Casualty record · 1

22 July 2011Routine · role: Involved in a Marine Casualty · activity 4096335
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

KAVIK RIVER (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.