MAURY USCG vessel records
← All vessels

ARGO

ARGO is a 2009 tank ship. The Coast Guard has recorded 6 inspections since 2017, most recently in March 2022, along with 3 deficiencies and 1 operational control.

Records from 2017 to 2022. Most recent: inspection, 15 March 2022.

Built
2009
Last inspected
15 March 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 March 2022
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9417464
1048602
Flag
MARSHALL ISLANDS
Maury page id
psix-1048602

Documentation record

Tonnage as PSIX records it57281 - Convention (Subpart B), Gross Ton
33014 - Convention (Subpart B), Net Ton
105188 - Dead Weight, Metric Ton
118745 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

15 March 2022 COC-TVE Renew · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7409424
17 September 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7314698
15 October 2020 PSC B · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7069364
14 October 2019 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6831066
19 June 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6436051
4 May 2017 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6133599

Deficiency record · 3

Fire Fighting › Remote Fuel Shutoff › General
Issued 4 May 2017 Resolved
0799-Other(Fire Fighting Equipment)-Oil fuel pipes which, if damaged, would allow to escape from a daily service tank of a 500l capacity and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position in the event of a fire. PSCO observed pneumatic line to quick closing valve for MGO service tank was disconnected. SOLAS 74 (2009) II-2/4.2.2.3.4 30ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 5 May 2017
Resolution: Received Class Society Report from Lloyd's Register. Class Surveyor witness connection and operation of LSMGO quick closing valve. Proper arrangements verified,
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 4 May 2017 Resolved
1820-Cargo Pump Room/Handling Spaces-No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless the Administration is satisfied that: of a type which will not ignite the mixture concerned. SOLAS74 (2014) II-2/45.10 ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 5 May 2017
Resolution: Received Class Society Report from Lloyd's Register. Class Surveyor verified packing glands in place. In addition, heat shrink tubing placed to reinforce gas tightness of the items. On completion all found in order.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 May 2017 Resolved
1745-15 PPM Alarm Arrangements-OWS shall be provided with an alarm having regard to the specification recommended by the Organization. Vessel is fitted with MPEC.107(49) alarm. Oil record book Part I states vessel discharged using OWS on 01MAY2017, however, PSCO observed system indicating separator was off when system was running. The display showed rest of system operating. MARPOL I/13.7 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2017
Resolved 5 May 2017
Resolution: Received Class Society Report from Lloyd's Register. Spare display fitted and tested to satisfaction.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.