THOR CALIBER is a 2008 freight ship. The Coast Guard has recorded 9 inspections since 2018, most recently in January 2026, along with 1 deficiency and 1 operational control.
Records from 2018 to 2026. Most recent: operational control imposed, 27 January 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it32415 - Convention (Subpart B), Gross Ton 19353 - Convention (Subpart B), Net Ton 58732 - Dead Weight, Metric Ton 67808 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
27 January 2026PSC B · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8302581
12 January 2026PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8285322
24 June 2024PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7934124
13 April 2021PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7160647
9 July 2019Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6733212
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Quantity of Foam-Forming Liquid
Issued 19 January 2018Resolved
MAINTENANCE, TESTING AND INSPECTIONS SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION (MSC. 1/CIRC. 1432), TAKE SAMPLES FROM ALL FOAM CONCENTRATES AND SUBJECT THE TO THE PERIODICAL CONTROL TESTS IN MSC/CIRC.670. FOAM ANALYSIS REPORT WAS PAST THE YEARLY REQUIRED TESTING.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2018
Resolved 25 January 2018
Resolution: Foam analysis completed by Global Marine Safety on 24JAN18. All satisfactory.