MAURY USCG vessel records
← All vessels

FRONT EMINENCE

FRONT EMINENCE is a 2009 tank ship. The Coast Guard has recorded 2 inspections in 2021, along with 4 deficiencies — 1 with no resolution recorded —.

Records in 2021. Most recent: inspection, 22 August 2021.

Built
2009
Last inspected
22 August 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9353802
1048881
Flag
MARSHALL ISLANDS
Maury page id
psix-1048881

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…past their stated due date1
Years with a record 1 calendar year (2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it364050 - Displacement, Ton
321300 - Dead Weight, Ton
162706 - Convention (Subpart B), Gross Ton
112192 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

22 August 2021 COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7279557
8 August 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7280225

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 August 2021 Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side. During operational test of non-follow up unit the rudder was not able to move from Port to Starboard. Rectify prior to movement 74 SOLAS (20) II-1/29.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2021
Resolution: Technician adjusted steering gear electrical and travel limits. Class verified proper operation.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 August 2021 Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over from 35 degrees on one side to 35 degrees on the other side. The follow up, main steering unit, was unable to put the rudder all the way over to 35 degrees starboard while the #2 steering pump was energized, and it caused an alarm preventing the rudder from being moved. Rectify deficiency prior to movement. 74 SOLAS (20) II-1/29.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2021
Resolution: Technician made adjustments to the system, Class verified proper operation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 August 2021 No resolution recorded
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO identifies 7 quick closing valves tied open with wire preventing closure. Crew stated they had placed wire in preparation for USCG exam to prevent inadvertent shut-down of running machinery. Vessel has no written procedure to block quick closing vales. 74 SOLAS (20) IX/3.1 - ISM code 10.1
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2021 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 August 2021 Resolved
Oil fuel pipes for daily service tank having a capacity of 500L and above shall be fitted with a valve capable of being closed from outside the space. 7 quick closing valves on the fuel service tank were tied open preventing closure from outside the space. 74 SOLAS (20) II-2/4.2.2.3.4
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 August 2021
Resolution: 2/E removed the wire-tie hold-open devices from the quick closing valves

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.