Records from 2016 to 2026. Most recent: inspection, 15 July 2026.
Inspection history · 23
15 July 2026
Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8440544
15 April 2026
PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8346904
18 January 2026
Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8298023
17 January 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8297743
15 October 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8253643
13 October 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8251249
10 October 2025
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8250405
7 October 2025
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8245413
3 August 2025
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8200992
23 July 2025
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8189427
19 July 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8189422
20 October 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7336342
2 June 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7213184
26 April 2021
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7178437
19 January 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6892252
16 July 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6739390
16 July 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6760550
13 December 2018
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6592068
6 December 2018
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6592934
4 August 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6500331
2 March 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6364778
8 January 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6067639
6 October 2016
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6017357
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 July 2025
Resolved
Liferafts intended for throw overboard launching shall be stowed to be readily transferable for launching on either side of the ship unless liferafts of aggregate capacity are stowed on each side of the ship. Psco observed foward liferaft not easily transferable.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2025
Resolution: Received Class report attesting to the proper location of the forward life raft. Conducted def check and witnessed the proper installation to comply with Solas 74 III/29
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 July 2025
Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed channel drains on cargo holds unable to be plugged due to current design.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2025
Resolution: New drain valves have been ordered but are delayed. KR reportedapproves temporary measures until parts are obtained. Risk assessment completed. Def changed to a 15ac (Next Port)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 April 2021
Resolved
THE SIDES AND THE REAR AND, WHERE NECESSARY, THE FRONT OF SWITCHBOARDS SHALL BE SUITABLY GUARDED. IN BOTH ENGINE CONTROL ROOM AND EMERGENCY GENERATOR SPACE, SWITCHBOARD DOES NOT TOUCH CEILING AND HAS NO FRONT DRIP GUARD.
74 SOLAS (04) II-1/45.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 April 2021
Resolved 2 June 2021
Resolution: Vessel installed appropriate guard and survey was conducted by their classification society.