MAURY USCG vessel records
← All vessels

L' AUSTRAL

L' AUSTRAL is a 2010 passenger vessel (inspected). The Coast Guard has recorded 5 inspections since 2016, most recently in September 2023, along with 9 deficiencies — 7 with no resolution recorded —.

Records from 2016 to 2023. Most recent: inspection, 18 September 2023.

Built
2010
Last inspected
18 September 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 September 2023
…past their stated due date5
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9502518
1049065
Flag
FRANCE
Maury page id
psix-1049065

Documentation record

Tonnage as PSIX records it10944 - Convention (Subpart B), Gross Ton
1441 - Dead Weight, Ton
7520 - Displacement, Ton
3427 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

18 September 2023 Polar Code Examination · PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7790343
15 September 2022 PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7558353
15 September 2019 COC-CVE Annual · Ballast Water Examination · ISPS II Exam · Polar Code Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6811403
30 September 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6030392
3 September 2016 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5980108

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 September 2023 No resolution recorded
07105 - Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO's observed every hinged fire door in main vertical zone bulkheads, galley boundaries, and stairway enclosure throughout the entire ship closing in less than 5 seconds. 74 SOLAS 20 II-2/9.4.1.1.5.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 September 2023 No resolution recorded
07105 - Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCO's observed crew a noticeable air gap betwen the door frame and the bulkhead on crew laundry door on deck 1. The door frame did not appear to be attached to the bulkhead on hinged side of door. 74 SOLAS 20 II-2/9.4.1.2.1
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 September 2023 No resolution recorded
07113 - Fire fighting systems, and appliances shall be kept in good working order and readily available for immediate use. PSCO observed a temporary patch on the discharge side of the main fire pump. 74 SOLAS 20 II-2/10.2.2.2
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 September 2023 No resolution recorded
04103 - The means of escape shall be marked with lightin or photoluminescent strip indicators placed not more than 300 mm above the deck. PSCO observed that the low location lighting in the escape route aft starboard stairway was obstructed with boot storage on deck 4 and storage boxes on deck 5. 74 SOLAS 20 II-2/13.3.2.5.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 September 2023 No resolution recorded
07105 - The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed the roller shutter fire door in deck 6 pantry did not close when actuated. 74 SOLAS 20 II-2/9.4.1.1.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 September 2023 No resolution recorded
15109 - The company should ensure that inspections are held at appropriate intervals; any non-conformity is reported, if possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. In regard to the fire screen door deficiency, the required inspections and follow up actions of the ship do not appear to be completed as required by their SMS procedures. 74 SOLAS 20 IX/3.1 & ISM Code A.10.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 September 2022 No resolution recorded
Vessel must comply with specific provisions minimum of Tables 9.1 and 9.2. Vessel has removed insulation on emergency generator fuel tank. Reinstall per regulation or receive approval from RO for current arrangement. 74 SOLAS 20 II-2/9.2.2.3.1 50a
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2019 Resolved
Fire doors in stairway enclosures shall be self closing and fitted with a self closing hose port. FSD DB 05 (entrance door to the engine room) was incapable of self closing and had a hose port that was stuck open. SOLAS 74 (2014 CONS. ED.) II-2 Reg. 9/4.1.1.5 and Reg. 9/4.1.1.8
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 15 September 2019
Resolved 15 September 2019
Resolution: Repairs made prior to completion of examination.
Fire Fighting › Structural - A Class Divisions › External Escape Routes
Issued 3 September 2016 Resolved
Fire screen dor DB 07 has a penetration at the lower right side of the door, door is marked escape hatch. SOLAS 74 (2009 cons) Chap II-2 Reg 9.1.3
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 30 September 2016
Resolution: Class Letter

Ownership record