← All vessels
GLORIOUS LEADER
GLORIOUS LEADER is a 2007 freight ship. The Coast Guard has recorded 16 inspections since 2009, most recently in July 2026, along with 3 deficiencies and 1 operational control.
Records from 2009 to 2026. Most recent: inspection, 10 July 2026.
- Built
- 2007
- Last inspected
- 10 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9357298 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6VT9
1049328
Flag
BAHAMAS, THE
—
Maury page id
psix-1049328
Inspections, by type
…with no type recorded2
Years with a record
10 calendar years (2009–2026)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it38050 - Displacement, Ton
21021 - Dead Weight, Ton
57692 - Convention (Subpart B), Gross Ton
21037 - Convention (Subpart B), Net Ton
21021 - Dead Weight, Ton
57692 - Convention (Subpart B), Gross Ton
21037 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
10 July 2026
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8430382
12 January 2025
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8058633
24 January 2024
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7853733
1 October 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7801320
4 January 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7616196
9 November 2021
PSC B · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7347802
2 August 2021
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7274863
25 October 2018
In-Service Inspection · Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6567811
24 October 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6567592
24 October 2018
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6584052
7 May 2018
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6408356
18 January 2018
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6337499
15 January 2016
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5798364
28 October 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5748149
1 December 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4199069
4 December 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3644545
Deficiency record · 3
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 9 November 2021
Resolved
General arrangement plans shall be permenently exhibited for each deck, the control stations, the various fire sections enclosed by an "A" class divisions, the sections enclosed by "B" class divisions. PSCO observed a self closing door listed on the fire control plan as such and the closing mechanism having been removed.
Construction/Loadline › Hull › Side Shell
Issued 28 October 2015
Resolved
No change shall be made in the structure, equipment, arrangements, material, or scantlings covered by the survey. PSCO examiners observed 8" inset and 18" crease approximately 6" in depth on the aft starboard side side shell about 1' above the waterline.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 October 2015
Resolved
Electrical services essential for safety will be ensured under various emergency conditions. Observed two emergency lights inoperable in the midships’ exterior passageway. Crew replaced bulbs and verified proper operation.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.