MAURY USCG vessel records Sign in
← All vessels

LARDOS

LARDOS is a 2009 freight ship. The Coast Guard has recorded 13 inspections since 2009, most recently in October 2024, along with 3 deficiencies and 2 operational controls.

Records from 2009 to 2024. Most recent: inspection, 29 October 2024.

Built
2009
Last inspected
29 October 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9550280 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V9360
1049409
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1049409

Inspections, by type

…with no type recorded3
Years with a record 6 calendar years (2009–2024)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it34753 - Displacement, Ton
28339 - Dead Weight, Ton
17019 - Convention (Subpart B), Gross Ton
10108 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AEP 7020 Freight Barge · MISLE 939085 · 4 January 2010 · activity 3845558

Inspection history · 13

29 October 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8024683
26 October 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8024987
26 October 2024 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8024996
3 February 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6901465
11 July 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6745636
19 July 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4087573
17 July 2011 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4084357
13 July 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4071558
12 July 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4071563
4 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3658672
4 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3845558
3 January 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3658657
2 December 2009 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex VI Survey · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3640144

Deficiency record · 3

Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 13 July 2011 Resolved
0899 - Other (Accident Prevention) - Each transfer pipe shall be hydrostatically tested annually to 1.5 times MAWP. Vessel could not provide proof of hydrostatic test to 1.5 times MAWP. Provide documentation prior to transfer in US. - 33 CFR 156.170
Action required: 703 - Prior to bunkering operations
Resolved 17 July 2011
Resolution: Vessel submitted documentation attesting to hydrostatic testing.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 13 July 2011 Resolved
1740 - Oil Discharge Mon/contr system, Masters & crew shall be familiar with essential shipboard procedures relating to the prevention of pollution by oil. This was written taking into account the guidance in MEPC 107(49), Engineering crew could not demonstrate the ability to recover Oil Content Meter logged data. Provide corrective action plan from company with concurrence from Admin. MARPOL 1-11
Due 27 July 2011
Resolved 19 July 2011
Resolution: Received proper documentation satisfying the requirement.
Construction/Loadline › Hull › Hull Plating
Issued 4 January 2010 Resolved
Vessel was involved in an allision with a barge while on the Mississippi river, which resulted in hull damage to the starboard strakes.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2010
Resolved 4 January 2010
Resolution: Received, reviewed, and accepted class report from Nippon [name withheld] stating the deficiency was rectified. The report stated that no fractures were observed and permanent repairs to made no later than next dry docking.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.