Records from 2009 to 2011. Most recent: operational control imposed, 8 February 2011.
Inspection history · 6
8 February 2011
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3941196
8 February 2011
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3941197
28 November 2010
Ballast Water Examination · PII Safety Exam · COE-Dockside · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3899692
22 February 2010
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3683649
2 December 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3641617
2 December 2009
MARPOL Annex I Examination · Ballast Water Examination · COE-Offshore · ISPS I Exam · PI Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3642503
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 29 November 2010
Resolved
The machinery shall be of design and construction adequate for the service they intended. Charge air pressure guage on #1 and #2 main generators found broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 12 February 2011
Accommodation/Occupational Safety › Messroom › Location
Issued 29 November 2010
Resolved
Upon inspection of the galley, infestation of roaches was discovered, requiring fumigation of the galley space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 12 February 2011
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 29 November 2010
No resolution recorded
While conducting hull and deck walk, several mooring lines were found to be spliced and frayed through out the lines. Require mooring lines to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2011 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Ventilation › General
Issued 28 November 2010
No resolution recorded
Upon inspection of the galley, it was found that the hood vent system was not working as designed. Vessel shall make repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2011 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 November 2010
Resolved
Effective guard rails shall be fitted to all exposed parts of the deck. Several spots forward port and starboard were found wasted and detatched and not fit as designed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 December 2010
Resolved 12 February 2011
Engineering › Steering Gear System › Pump
Issued 2 December 2009
Resolved
Hydraulic power operated steering gear shall be provided with a low level alarm for each reservoir and audible and visual alarms shall be given on the navigational bridge and machinery space. Chief Engineer was unfamiliar with procedures to simulate alarm and therefore it was not observed.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 22 February 2010
Resolution: Received master statement to proper operations of alarm circuit .