Records from 1988 to 2010. Most recent: inspection, 24 March 2010.
Inspection history · 62
24 March 2010
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3702820
9 September 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3320770
18 June 2008
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3248615
26 April 2008
Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 3193019
10 December 2007
Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3112859
11 September 2007
Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3054116
11 September 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2775204
27 June 2005
Type not recorded
No type recorded · Station Boston · USCG Northeast District (CGD-NE) · Activity 2404552
25 June 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2318951
2 June 2005
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2376582
7 July 2004
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2124999
18 December 2003
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1966067
11 August 2003
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1872884
30 June 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1946178
28 August 2002
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1667887
7 March 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1650045
18 December 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1474356
4 June 2001
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1366385
9 April 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1060062
14 March 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1403309
14 June 2000
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1376233
21 December 1999
Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1413646
10 September 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1434925
12 April 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 144412
18 September 1998
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 800864
17 September 1998
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 800103
8 September 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1409970
7 May 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 799578
16 April 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1124457
6 January 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378265
11 July 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371906
9 June 1997
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1109702
9 October 1996
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 840725
11 September 1996
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1262120
12 July 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380577
9 May 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357604
29 August 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1191607
14 July 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1419476
29 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1446122
29 July 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1359881
15 July 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 871698
14 March 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1165714
5 January 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1161012
16 November 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1145667
3 November 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 844197
15 October 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 836051
4 March 1993
Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1451844
20 January 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 827826
16 November 1992
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1136096
7 August 1992
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1262286
22 June 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1261470
17 June 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 685892
16 June 1992
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 944251
28 May 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 673735
19 May 1992
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 88929
15 November 1991
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1003698
17 July 1991
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 926412
2 March 1990
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916246
30 November 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916873
19 May 1989
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 970540
29 June 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1034247
17 May 1988
Hull Examination · COI Inspection · Plan Review "T" Boat
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1348948
Construction/Loadline › Hull › Side Shell
Issued 9 September 2008
Resolved
repair small hole in sideshell forward IWO forepeak stbd 2" below main deck.
Due 9 September 2008
Resolved 17 September 2008
Resolution: hole repaired sat.
Engineering › Steering Gear System › Rudder Stock
Issued 9 September 2008
Resolved
Make repairs to leak in the port rudder post sleeve.
Due 9 September 2008
Resolved 17 September 2008
Resolution: new clamps added leaking addressed.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 10 December 2007
Resolved
Prior to the spring of 2008, replace all six cutlass bearings.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 18 June 2008
Resolution: All 6 cutlass bearings replaced to original condition
Lifesaving › Hand Flares › Quantity
Issued 11 September 2007
Resolved
Provide four additional orange smoke flares.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 11 September 2007
Resolved
Replace as needed the life lines around both buoyant apparatuses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 11 September 2007
Resolved
Replace the worn reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 September 2007
Resolved
Repair the punctures or replace the buoyant apparatuses. If repaired, use only Jimbuoy approved repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Resolution: Buoyant apparatuses repaired.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 11 September 2007
Resolved
Provide a sea rail on the front of the stove top.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 11 September 2007
Resolved
Label the emergency breaker shut off for the electric stove and provided an instruction placard for location of the breaker by the stove.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 September 2007
Resolved
Label the control panel on the bridge for each system: bilge dewatering system, navigation lights, horn, etc.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Documentation › Markings/Placards › Capacity Marking
Issued 11 September 2007
Resolved
Label the upper deck with the maximum amount of passengers allowed by the stability letter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 September 2007
Resolved
Provided an emergency broadcast instruction at each operating station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 17 September 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 11 September 2006
Resolved
Label vessel name and replace retro tape on 6 lifejackets.
Due 11 September 2006
Resolved 19 September 2006
Resolution: Life jackets repaired sat.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 11 September 2006
Resolved
Replace worn shaft packing for port shaft.
Due 11 September 2006
Resolved 19 September 2006
Resolution: Shaft packing replaced sat.
Engineering › Steering Gear System › Rudder Stock
Issued 11 September 2006
Resolved
Renew port rudder post packing gland.
Due 11 September 2006
Resolved 19 September 2006
Resolution: Repaired sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 June 2005
Resolved
Repair water leak in starboard main engine exhaust hose connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 24 August 2005
Engineering › Bilge Water Management System › Hose
Issued 2 June 2005
Resolved
Renew electric bilge pump plastic discharge hose located in the forward section of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 24 August 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 June 2005
Resolved
Secure the starting battery for the generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 24 August 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 2 June 2005
Resolved
Secure the fresh water pump/filter located in the engine room starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 24 August 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 June 2005
Resolved
Cover electrical receptacle box for the air compressor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 24 August 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 2 June 2005
Resolved
Provide globes and guards for light fixtures in the engine room (port).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 24 August 2005
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 2 June 2005
Resolved
Clean fuel tank area next to a cable/pipe run.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2005
Resolved 24 August 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 July 2004
Resolved
Vessel limited to 54 allowable persons onboard until one more adult PFD is provided
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 7 July 2004
Resolution: Life jacket provided
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 July 2004
Resolved
Label PFD stowage on upper deck
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 7 July 2004
Resolution: Labeled
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 7 July 2004
Resolved
Place double clamping on generator muffler hose
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 7 July 2004
Resolution: Clamped
Engineering › Bilge Water Management System › Piping
Issued 7 July 2004
Resolved
Label bilge piping.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 7 July 2004
Resolution: Labeled
Engineering › Bilge Water Management System › Manifold
Issued 7 July 2004
Resolved
Provide bilge system line diagram and post
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 7 July 2004
Resolution: Provided diagram
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 July 2004
Resolved
Place machinery guard on stbd engine where PTO is located
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 7 July 2004
Resolution: Provided guards
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 July 2004
Resolved
Place proper reflective tape on pilot house life ring
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 7 July 2004
Resolution: Provided retro reflective
Accommodation/Occupational Safety › Occupational Safety
Issued 18 December 2003
Resolved
Wooden hand rail and metal stanchion in need of repair. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 16 January 2004
Resolved 23 February 2004
Resolution: Wooden hand rail and stanchions repaired to the satisfaction of the marine inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2003
Resolved
Prove proper operation of stern light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2003
Resolved 13 August 2003
Resolution: Witnessed satisfactory test of stern light.
Documentation › Markings/Placards
Issued 11 August 2003
Resolved
Properly mark vessel name on port and starboard bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 27 August 2003
Resolution: Examined satisfactory vessel name marking on port/stbd bow.
Lifesaving › Hand Flares › Quantity
Issued 11 August 2003
Resolved
Provide four additional hand-held orange smoke distress signals for a total of six.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2003
Resolved 13 August 2003
Resolution: Examined and found satisfactory six new orange smoke signals.
Lifesaving › Buoyant Apparatus
Issued 11 August 2003
Resolved
Properly make up pendants on buoyant apparatuses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2003
Resolved 13 August 2003
Resolution: Examined and found satisfactory pendants.
Communications › Radio Communications › EPIRB
Issued 11 August 2003
Resolved
Renew expired hydrostatic release mechanism for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2003
Resolved 13 August 2003
Resolution: Examined new hydro-release with expiration date of AUG 2005.
Engineering › Bilge Water Management System › Pump
Issued 11 August 2003
Resolved
Prove proper operation of installed electric bilge pumps.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2003
Resolved 13 August 2003
Resolution: Witnessed satisfactory test of electric bilge pumps.
Construction/Loadline › Hull › Hull Plating
Issued 11 August 2003
Resolved
Verify integrity of hull plating where evidence of corrosion exists on transom amidships IWO connection to bottom plating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 13 August 2003
Resolution: Examined affected area and found it to be sound.
Engineering › Bilge Water Management System
Issued 11 August 2003
Resolved
Prove proper operation of installed bilge pumping system. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2003
Resolved 27 August 2003
Resolution: Witnessed satisfactory test of new PTO bilge pump taking suction for the engine room and discharging to sea.
Operations/Management › Drills/Instruction
Issued 11 August 2003
Resolved
Conduct man overboard and fire drills in the presence of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2003
Resolved 13 August 2003
Resolution: Witnessed satisfactory fire and MOB drills.
Communications › Radio Communications
Issued 28 August 2002
Resolved
Provide documentation for the new EPIRB battery. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 5 September 2002
Resolution: New battery present.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 28 August 2002
Resolved
Properly label the upper deck. LEGACY COMPONENT DESC: Open Deck Space
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 5 September 2002
Resolution: Second deck properly labeled.
Navigation › Piloting/Steering
Issued 28 August 2002
Resolved
Provide new navigation rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 5 September 2002
Resolution: Navigation rules present.
Accommodation/Occupational Safety › Occupational Safety
Issued 28 August 2002
Resolved
Provide a belt guard for the starboard main engine alternator. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 27 September 2002
Engineering › Shafting/Propeller Arrangements
Issued 28 August 2002
Resolved
Tighten packing for the starboard main engine shaft. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 5 September 2002
Resolution: Packing for stbd tightened.
Engineering › Sea-water System (primary cooling)
Issued 28 August 2002
Resolved
Properly tighten the port side exhaust hose on the lower end (outboard of the main engine). LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 5 September 2002
Resolution: Exhaust hose tightened.
Construction/Loadline › Hull › Bottom Plating
Issued 7 March 2002
Resolved
Make permanent repairs to temporarily patched hole in bottom plating, starboard side, amidships, in way of batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2002
Resolved 7 March 2002
Resolution: Examined 18" x 18" hull insert plate. Witnessed satisfactory hose test.
Construction/Loadline › Hull › Side Shell
Issued 18 December 2001
Resolved
Puncture holes in port and starboard side shell, in forepeak, in way of integral headlights. Existing damage was improperly repaired with patches of plywood, fibreglass and Bondo, then covered on the exterior with fairing compound.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2001
Resolved 28 December 2001
Resolution: Damaged shell plating was cropped and renewed with 24" x 16" aluminum insert. Witnessed satisfactory hose test of same.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 December 2001
Resolved
Port stern tube bearing and both port strut bearings worn down approximately 90% and require renewal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2001
Resolved 28 December 2001
Resolution: Examined newly installed port strut and stern tube bearings. Owner also renewed port shaft due to the old one being seized to the coupling, preventing its removal intact.
Engineering › Bilge Water Management System › Strainer
Issued 18 December 2001
Resolved
Strainer was missing on bilge suction in forward hold
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2001
Resolved 21 December 2001
Resolution: Strainer examined and found to be properly installed.
Construction/Loadline › Penetrations
Issued 18 December 2001
Resolved
Ball valve inoperative on blanked-off 1 1/2" thru-hull fitting in port head in accommodations space. LEGACY COMPONENT DESC: Sea valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2001
Resolved 21 December 2001
Resolution: Newly installed valve examined and found satisfactory.
Construction/Loadline › Hull › Bottom Plating
Issued 18 December 2001
Resolved
Access plates outboard of port and starboard main engines obstructed view of interoir of hull in that area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2001
Resolved 21 December 2001
Resolution: Examined and found satisafctory.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 18 December 2001
Resolved
Port and starboard propellers had numerous dents and dings. Owner indicated intent to install new propellers Spring 2002.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2002
Resolved 28 December 2001
Resolution: Examined propellers which had been ground down satsfactorily to remove most of the damage. Owner still intends on renewing propellers, but the repair was adequate for srevice at this time.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 18 December 2001
Resolved
Port and starboard spool pieces for main engine raw water suction found to be wasted and required renewal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2001
Resolved 28 December 2001
Resolution: New spool pieces examined and found satisfactory.
Lifesaving
Issued 14 March 2001
Resolved
The vessel is restricted to 36 total persons until additional primary lifesaving equipment is provided.
Condition: Unknown
Due 15 April 2001
Resolved 9 April 2001
Navigation
Issued 14 June 2000
Resolved
PROPERLY REPAIR THE LEAKING FROM BOTH RUDDER SHAFTS NO LATER THAN 30 NOV 00OR AT NEXT HAUL OUT.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 21 December 1999
Resolved
PRIOR TO CARRYING PASSENGERS PROPERLY RENEW THE STARBOARD SIDE OVERBOARD DISCHARGE LINE FOR THE JABSCO PUMP.
Condition: Unknown
Due 28 December 1999
Resolved 27 December 1999
Electrical
Issued 21 December 1999
Resolved
PROPERLY REPAIR/REPLACE THE WIRE RUN IN THE PORT SIDE ENGINEROOM OVERHEAD.
Condition: Unknown
Due 28 December 1999
Resolved 23 December 1999
Engineering
Issued 21 December 1999
Resolved
PROPERLY RENEW THE RUBBER EXHAUST PIECE IN THE PORT AFT MACHINERY SPACE.
Condition: Unknown
Due 28 December 1999
Resolved 27 December 1999
Construction/Loadline
Issued 21 December 1999
Resolved
PROPERLY CAP THE UNUSED OVERBOARD LINE IN THE PORT SIDE MACHINERY SPACE IWOTHE BATTERY BOX.
Condition: Unknown
Due 28 December 1999
Resolved 27 December 1999
Fire Fighting
Issued 10 September 1999
Resolved
Properly hydro test the machinery space fixed firefighting system.
Condition: Unknown
Due 24 September 1999
Resolved 22 September 1999
Documentation
Issued 10 September 1999
Resolved
Provide the company policy/hotline #'s and contract for the drug testing program.
Condition: Unknown
Due 24 September 1999
Resolved 22 September 1999
Documentation
Issued 10 September 1999
Resolved
Properly post the oil pollution placard.
Condition: Unknown
Due 24 September 1999
Resolved 22 September 1999
Lifesaving
Issued 10 September 1999
Resolved
Provide (1) one type 1 child life preserver. The vessel is limited to 5 children.
Condition: Unknown
Due 24 September 1999
Resolved 22 September 1999
Lifesaving
Issued 10 September 1999
Resolved
Provide 2 waterlights for the BA's. The vessel is limited to operations not more than 1 mile from land.
Condition: Unknown
Due 24 September 1999
Resolved 22 September 1999
Lifesaving
Issued 10 September 1999
Resolved
Properly post the appropriate life jacket donning placards.
Condition: Unknown
Due 24 September 1999
Resolved 22 September 1999
Documentation
Issued 12 July 1996
Resolved
Provide radiotelephony certificate.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Lifesaving
Issued 12 July 1996
Resolved
Provide proper size weak link for buoyant apparatus.
Condition: Unknown
Due 26 July 1996
Resolved 16 July 1996
Documentation
Issued 12 July 1996
Resolved
Provide radio operator's license.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Navigation
Issued 12 July 1996
Resolved
Provide pressure relief valve for horn's air storage tank.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Documentation
Issued 12 July 1996
Resolved
Provide radio station license reflecting current vessel name.
Condition: Unknown
Due 12 July 1996
Resolved 12 July 1996
Electrical
Issued 3 November 1993
Resolved
REMOVE WING NUTS FROM BATTERY TERMINALS. PROVIDE AND INSTALL PROPER FASTENERS AS PER 46 CFR 183.05-20(c).
Condition: Unknown
Due 10 November 1993
Resolved 17 November 1993
Electrical
Issued 3 November 1993
Resolved
REMOVE ALL EXCESS WIRES FROM BATTERY TERMINALS AND PROVIDE PROPER TERMINAL STRIP WITH SINGLE FUSED SOURCE OF POWER IN ACCORDANCE WITH GOOD MARINE PRACTICE.
Condition: Unknown
Due 10 November 1993
Resolved 17 November 1993
Electrical
Issued 15 October 1993
Resolved
INSTALL BLANKS ON 32V DC STARBOARD LOAD CENTER.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Engineering
Issued 15 October 1993
Resolved
STOP OIL LEAKAGE AT PORT AND STARBOARD ENGINE VALVE COVERS.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Accommodation/Occupational Safety
Issued 15 October 1993
Resolved
INSTALL PROPER COURSES BETWEEN BOW RAILING ON MAIN DECK. COURSES SHALL BE INSTALLED WITH NO MORE THAN 12 INCHES BETWEEN ANY TWO COURSES.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Engineering
Issued 15 October 1993
Resolved
PROVE PROPER OPERATION OF BOTH EMERGENCY FUEL SHUT-OFFS.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Accommodation/Occupational Safety
Issued 15 October 1993
Resolved
PROVIDE PRESSURE/TEMPERATURE RELIEF VALVE FOR WATER HEATER RATED FOR NOT MORE THAN 100PSI-210 DEGREES FAHRENHIET.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Electrical
Issued 15 October 1993
Resolved
PROVIDE COVER FOR ALL LIGHT SWITCHES IN ENGINE ROOM.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Construction/Loadline
Issued 15 October 1993
Resolved
CAP OFF OR PROVIDE METALLIC VALVE FOR THROUGH HULL FITTING ON PORT SIDE OF ENGINE ROOM.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Engineering
Issued 15 October 1993
Resolved
PROVIDE COVER FOR ALTENATOR BELTS ON STARBOARD ENGINE.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Accommodation/Occupational Safety
Issued 15 October 1993
Resolved
PROVIDE SAFETY COVER FOR FORWARD EMERGENCY EXIT HATCH.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Construction/Loadline
Issued 20 January 1993
Resolved
MAKE PERMANENT REPAIR AND PROVE WATERTIGHT, SOFT DECK AREA OUTBOARD OF HOUSE FWE STBD CORNER.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Accommodation/Occupational Safety
Issued 20 January 1993
Resolved
PROVE THE EXCAPE HATCH LOCATED ON THE FWD MAIN DECK IS OPERABLE FROM BOTH SIDES.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Fire Fighting
Issued 19 May 1989
Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Fire Fighting
Issued 19 May 1989
Resolved
PROVIDE HAND PORTABLE FIRE PUMP CAPABLE OF PUMPING AT LEAST 5 GPM.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Documentation
Issued 19 May 1989
Resolved
PROVIDE VALID FCC OPERATORS LICENSE.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Lifesaving
Issued 19 May 1989
Resolved
PROVIDE ADDITIONAL 12 ADULT AND 2 CHILD LIFE PRESERVERS.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Documentation
Issued 19 May 1989
Resolved
PROVIDE AND POST EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989