Records from 2009 to 2019. Most recent: inspection, 9 May 2019.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
9 May 2019
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6676315
19 April 2016
Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5855456
4 January 2010
Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3658247
14 December 2009
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3650279
8 December 2009
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3644746
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 May 2019
Resolved
Except as provided in paragraphs 3.4.4 and 3.4.5, each lifeboat shall be launched, and maneuvered in the water by its assigned operating crew, at least once every three months. Lifeboat drills have not been conducted in five months. 74SOLAS(14)III/19.3.4.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 June 2019
Resolution: Received class report attesting to satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 9 May 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations...PSCO witnessed cooling water leaking from IG scrubber site glass. 74SOLAS(14)I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 June 2019
Resolution: Received class report attesting to satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 May 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations...Door to CO2 room was unable to be opened. In addition, multiple self closing doors were not capable of securing. 74SOLAS(14)I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 9 May 2019
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 14 December 2009
Resolved
1599 - Installed AIS is unable to provide gyro course information to attending river pilot's computer. AIS must be suitable for providing ship's identity, type, position, course, speed, navigational status, and other safety related information.
SOLAS 74 (2004 cons. ed) CH. V 19.2.4 70(a)(c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 December 2009
Resolution: Technician corrected the issue, and submitted the report to USCG. Class submitted their report also.
Lifesaving › Immersion Suits › General
Issued 8 December 2009
Resolved
0663; All of the immersion suits are too large for most of the crew. Suits of appropriate size should be provided, SOLAS 74 AM III/32.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2009
Resolved 8 December 2009
Resolution: Spoke with the Captain, Company Representative and [name withheld] about this matter.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 8 December 2009
Resolved
2120; Mixed garbage was found in the engine room and galley. Incineration of garbage is not being recorded in the garbage log. Harmful waste is not being separated as per the ships garbage plan, MARPOL V/9.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2009
Resolved 8 December 2009
Resolution: Spoke with the Captain, Company Representative and [name withheld] about this matter.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 8 December 2009
Resolved
0330; Sewage treatment plant is not being maintained as per the manufacturers requirements and chlorine tablets have not been added, 33 CFR 159.121(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2009
Resolved 8 December 2009
Resolution: Spoke with the Captain, Company Representative and Chief Engineer about this matter.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 December 2009
Resolved
1830; Cargo Transfer procedures are not in accordance with the Code of Federal Regulations, 33 CFR 155.750.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2009
Resolved 8 December 2009
Resolution: Gave a sample copy of the procedures to the Captain and spoke with the Company Representative and [name withheld] about this matter.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 8 December 2009
Resolved
2510; Ballast water handling log form being used is not the same as the Ballast Plan approved by ABS. Company should address this with Class.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 December 2009
Resolved 8 December 2009
Resolution: Spoke with the Captain, Company Representative and [name withheld] about this matter.