GRAN COUVA

GRAN COUVA is a 2008 tank ship. The Coast Guard has recorded 25 inspections since 2016, most recently in May 2024, along with 5 deficiencies and 9 operational controls.

Records from 2016 to 2024. Most recent: inspection, 20 May 2024.

Built
2008
Last inspected
20 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 May 2024
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9380520
1049991
Flag
HONG KONG
Maury page id
psix-1049991

Documentation record

Tonnage as PSIX records it29263 - Convention (Subpart B), Gross Ton
12026 - Convention (Subpart B), Net Ton
56280 - Displacement, Metric Ton
47128 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

20 May 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7915609
28 April 2023 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7683988
17 February 2023 COC-CHEM Annual
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7635155
16 February 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7392933
26 April 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7182670
25 April 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7182490
11 March 2021 PSC B · COC-CHEM Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7154047
27 January 2020 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6897232
23 January 2020 Deficiency Check · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6894600
7 March 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6628828
14 July 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6483177
4 May 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6405818
3 May 2018 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6404328
2 May 2018 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6404345
24 January 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6338058
8 June 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6169651
6 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6168390
23 January 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075647
20 January 2017 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6073766
8 September 2016 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5995776
30 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5987157
5 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5869673
2 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5866815
1 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6033969
1 February 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802687

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2021 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. Vessel cannot change from going ahead to astern at a speed of greater than 2 - 3 knots. 74 SOLAS (14 Cons) II-1/28.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2021
Resolution: PTM was downgraded to PTD
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2021 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. Vessel cannot shift from going ahead to going astern at a speed greater than 3 knots.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2021
Resolution: Received class survey attesting to the effective repairs on the main engine start air system, opp test sat, COTP lifted, PTD cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 January 2020 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the rescue boat engine is unable to operate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2020
Resolution: Received Class Report clearing outstanding deficiency. Vessel installed a new outboard motor to the satisfaction of class on the rescue boat.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 23 January 2020 Resolved
For tankers of 20000 DWT and upwards, the protection for the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements for the Fire Safety Systems Code. The IG System shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. PSCO observed that the IG Generator was unable to supply Inert Gas below 5%. Rectify issue prior to carrying flammable cargo.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 January 2020
Resolution: Recieved class report stating that the crew repalced the IP converter for the fuel oil line which regulates fuel pressure. IG system was tested in the presence of the class surveyor and verified that it was now producing below 5% oxygen by volume of IG.
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 June 2017 Resolved
1499: Starting devices approved by the administration shall be installed in each emergency generating set arranged to be automatically started. PSCO noted that the emergency generator auto start was not operable. 74SOLAS(14) II-1/44.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2017
Resolution: Vssl aquired new parts and installed, auto start fully operational. See attached Class report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.