MAURY USCG vessel records
← All vessels

FRATERNITY

FRATERNITY is a 2009 tank ship. The Coast Guard has recorded 5 inspections since 2017, most recently in July 2022, along with 3 deficiencies.

Records from 2017 to 2022. Most recent: inspection, 19 July 2022.

Built
2009
Last inspected
19 July 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 July 2022
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9416733
1050026
Flag
BELGIUM
Maury page id
psix-1050026

Documentation record

Tonnage as PSIX records it182856 - Displacement, Ton
157713 - Dead Weight, Ton
81482 - Convention (Subpart B), Gross Ton
51258 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

19 July 2022 PSC B · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7507444
16 October 2021 COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7326896
18 July 2020 COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6998770
20 August 2018 Deficiency Check · ISPS II Exam · Ballast Water Examination · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6517624
4 April 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6112147

Deficiency record · 3

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2020 Resolved
"High level alarm" is to be identified in black letters at least 2 inches high on a white backround. "High Level Alarm" was not identified for cargo fill alarms.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2020
Resolved 18 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 July 2020 Resolved
All life saving appliances sahll be in working order and ready for immediate use. Light connected to the starboard side life ring improperly attached so as it would not activate when deployed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 July 2020
Resolved 18 July 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 August 2018 Resolved
74 SOLAS (2014) CH.1/Reg.11(b) After any survey of the ship under Regulations 7.8.9 or 10 has been made in the structural arrangements, machinery, equipment, and other items covered by the survey. Temporary repair found on the salt water supply line for the deck water seal. Request that class is notified and addresses the repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 10 September 2018
Resolution: Received ABS Survey documents indicating repairs to the Deck Water Seal are complete and have passed inspection of ABS Surveyor. See documents section of file dated 10 Sept 2018 ABS Survey.

Ownership record