← All vessels
IOANNIS R
IOANNIS R is a 2008 freight ship. The Coast Guard has recorded 8 inspections since 2009, most recently in October 2024, along with 5 deficiencies and 1 operational control.
Records from 2009 to 2024. Most recent: inspection, 17 October 2024.
- Built
- 2008
- Last inspected
- 17 October 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9413418 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5UP2
1050028
Flag
LIBERIA
—
Maury page id
psix-1050028
Inspections, by type
The 8 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it75754 - Dead Weight, Ton
88557 - Displacement, Ton
41655 - Convention (Subpart B), Gross Ton
25807 - Convention (Subpart B), Net Ton
88557 - Displacement, Ton
41655 - Convention (Subpart B), Gross Ton
25807 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 8
17 October 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8020315
11 October 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8013669
28 December 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7113762
22 April 2019
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6632630
13 July 2016
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5930690
25 August 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4944845
9 August 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4110371
16 December 2009
ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3651169
Deficiency record · 5
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 October 2024
Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship. For this purpose, the following functional requirements shall be met: Means of control for the air supply to the space shall be provided. PSCO observed pneumatic leak on fire dampener system. Request clarification from certificate issuing authority to the continuing acceptance. 74 SOLAS (AM) II-2/5.1.1, Prior to movement, Code 60ac
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 October 2024
Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally allow exhaust ventilation and closure of ventilator dampers. PSCO observed engine room soft patch aft of pilot house found without any bolts mechanically securing the plate in place, compromising fire control boundary. Request clarification from certificate issuing authority to the continuing acceptance. 74 SOLAS (AM) II-2/5.2.2.1, Prior to movement, Code 60ac
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 October 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. PSCO observed multiple tie-backs in following locations: Galley to Pantry, Pantry to Messdeck, and Crew Smoking Lounge to athwartships passageway. 74 SOLAS (AM) II-2/14.2.1.1.1, Prior to movement, Code 60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 December 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed water leaking form cylinders 2, 3, and 5 on the main engine. This leak could result in engine overheating.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 July 2016
Resolved
0715- Detection-Fire detection and alarm systems shall be kept in good order to ensure their required performance. PSCO observed that the cargo hold smoke sample extraction system was off. When the crew turned the system on it displayed a fault in the no. 6 cargo hold. The crew cleaned the smoke extraction fan filter, and the fault cleared. The system is now operable- SOLAS 74 (09)am II-2/14 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.