Records from 2009 to 2026. Most recent: inspection, 2 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
2 March 2026
Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8318891
20 February 2025
Administrative Inspection · DAPI Audit · Special Consideration · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8082086
5 June 2024
Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7927741
10 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7635160
17 March 2022
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7413390
1 November 2021
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7358523
11 May 2021
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7194397
23 March 2020
Administrative Inspection · Drydock Exam · DAPI Audit · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6923981
25 March 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6648754
12 March 2018
Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6368947
5 April 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6113165
9 March 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5850117
4 March 2016
Hull Examination · Damage Survey · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5826917
24 March 2014
Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4822138
9 September 2011
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3913983
15 August 2011
Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4116404
4 December 2009
Construction Oversight · Plan Review "T" Boat
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3644556
Construction/Loadline › Hull › Weld
Issued 4 March 2016
Resolved
Vessels rear quarter panel was damaged as it fell of the trailer. The vessel was repaired in the presence of MI.
Condition: Damaged By Earlier Event
Due 4 March 2016
Resolved 4 March 2016
Resolution: Vessel cropped and renewed to orginal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2010
Resolved
Wire run supports do not meet ABYC E-11 or 46 CFR 183.340 and shall be corrected prior to certification.
Action required: 705 - Other - as specified
Due 29 March 2010
Resolved 8 April 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2010
Resolved
Forward rail coures openings were found to exceed 12" and shall be properly closed prior to certification.
Action required: 705 - Other - as specified
Due 29 March 2010
Resolved 8 April 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2010
Resolved
All around white navigation light does not meet NAVRULE requirements shall be raised prior to certification.
Action required: 705 - Other - as specified
Due 29 March 2010
Resolved 8 April 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 December 2009
Resolved
Wire splices do not meet ABYC E-11 or 46 CFR 183.340 and shall be corrected prior to certification.
Action required: 705 - Other - as specified
Due 29 March 2010
Resolved 8 April 2010