MAURY USCG vessel records
← All vessels

MOMI ARROW

MOMI ARROW is a 2009 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in September 2025, along with 21 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 16 September 2025.

Built
2009
Last inspected
16 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9385506
1050264
Flag
PANAMA
Maury page id
psix-1050264

Documentation record

Tonnage as PSIX records it54204 - Dead Weight, Ton
63514 - Displacement, Ton
30983 - Convention (Subpart B), Gross Ton
15721 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

16 September 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8234527
16 April 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7895939
11 April 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7893654
13 September 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7557760
27 May 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7460427
28 February 2022 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7399730
28 April 2020 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6944505
18 September 2019 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6813804
12 September 2019 Administrative Inspection · Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6805349
27 August 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6523972
23 August 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6520519
21 August 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6518368
29 July 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6218924
12 June 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5894094

Deficiency record · 21

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2022 Resolved
13101 - Propulsion and Auxiliary Machinery - The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of design and construction adequate for the service for which they are intended. PSCO found a temporary repair to #5 cylinder using synthetic patch to stop leak from lube oil system. 74 SOLAS (04)II-1/26.1 - 15ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 March 2022
Resolved 27 May 2022
Resolution: Recieved class report.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 February 2022 Resolved
07106 - Fire Safety - Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. PSCO observed crew using improper testing equipment for heat detectors. crew was using a heat gun, which is not recommended for testing. 74 SOLAS(04) II-2/14.1.2 - 15ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 March 2022
Resolved 27 May 2022
Resolution: Recieved class report.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 September 2019 Resolved
01 02108:The administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. PSCO noted that electrical panel cover latch was broken and would not close properly within the port side forward BOSN hole. (SOLAS 14 III/40.2)
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
Resolution: Crew replaced faulty latch.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2019 Resolved
02 11117: Cargo ships shall carry not less than 12 lifebuoys (150 and under 200M) complying with the requirements of regulations 7.1 and section 2.1 of the code. PSCO noted two wasted lifebuoys. (SOLAS 14 III/32.1.1)
Action required: 10 - Deficiency Rectified
Resolved 18 September 2019
Resolution: Vessel removed wasted lifebuoys from use and replaced with new ring lifebuoys.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 September 2019 Resolved
15109- Objective evidence discovered during an expanded ISM examination revealed the vessel failed to fully implement the requirements of the ISM Code through their Safety Management System (SMS) as evident in the identified major non-conformities listed in the deficiencies. An external audit is recommended. 74 SOLAS (14CONS) CH IX / Reg 3.1 ISM Code Part A 30 ABC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2019
Resolution: External audit conducted.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 September 2019 Resolved
15109- The company should establish procedures, plans and instructions, including checklists as appropriate for key shipboard operations. The vessel’s SMS for the checking of portable fire extinguishers requires the extinguishers to be checked in accordance with the maker’s instructions. A maintenance log for firefighting appliances is being utilized to conduct monthly checks. The checklist requires the crew member to ensure the extinguisher is in its appropriate location as per the fire plan and in good condition. The maker’s instructions include more items to be checked monthly; due to the limited checklist that the vessel is using, the extinguishers are not being fully inspected as per the maker’s instructions. This led to the identification of 11 out of 31 fire extinguishers not ready for immediate use. 74 SOLAS (14CONS) CH IX / Reg 3.1 ISM Code Part A 7 30 ABC
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 16 September 2019
Resolution: Vessel developed a new checklist for inspecting extinguishers.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 September 2019 Resolved
15109- Every company should develop, implement and maintain a safety management system which includes instructions and procedures to ensure safe operation of ships. The vessel’s SMS does not include an inspection of portable fire extinguisher’s spare charges. The vessel is required to carry 21 spare fire extinguishers or charges, the vessel was able to produce 1 spare fire extinguisher that was within maker’s operating parameters and ready for immediate use. The other spares onboard were manufactured in 2009 and required to be taken out of service after 5 years from manufacturing date. 74 SOLAS (14CONS) CH IX / Reg 3.1 ISM Code Part A 1.4.2 30 ABC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2019
Resolution: Vessel was provided with 21 spare charges for extinguishers.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 12 September 2019 Resolved
15111- The Company should define and document the responsibility, authority and interrelation of all personnel who manage, perform and verify work relating to and affecting safety and pollution prevention. Kiddie fire extinguishers were recently inspected by crew on 31AUG2019 with no mention of them being out of parameter. Kiddie fire extinguishers were out of parameter as per manufacturer’s manual, rendering them inoperable. 74 SOLAS (14CONS) CH IX / Reg 3.1 ISM Code Part A 3.2 30 ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2019
Resolution: The fire extinguisher checklist has been revised.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 September 2019 Resolved
15109- Every company should develop, implement and maintain a safety management system which includes instructions and procedures to ensure safe operations of ships. The vessel’s SMS section S-09.10.01-2.2 states that maintenance shall be carried out in accordance with the maker’s instructions. The maker’s instructions were not provided to the vessel for the heat detectors installed on the vessel. 74 SOLAS (14CONS) CH IX / Reg 3.1 ISM Code Part A 1.4.2 30 ABC
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 16 September 2019
Resolution: The vessel had 51 new extinguishers delivered.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 September 2019 Resolved
15109- The company should ensure that all personnel involved in the company's SMS have an adequate understanding of relevant rules, regulations, codes and guidelines. PSCO observed that the crew was not familiar with regulations regarding the testing of heat detectors onboard the vessel. 74 SOLAS (14CONS) CH IX / Reg 3.1 ISM Code Part A 1.4.2 30ABC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2019
Resolution: Crew has received training on the proper testing of heat detectors.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 12 September 2019 Resolved
15112- The annual survey shall include a general inspection of the structure, machinery and equipment referred to in paragraph (B)(I), to ensure that they have been maintained in accordance with regulation 11(A) and that they remain satisfactory for the service for which the ship is intended. A classification society survey was conducted on 02NOV2018 with no mention of expired and inadequate spare charges for fire extinguishers. Yamato fire extinguisher spare charges were found to be expired after August 2014. 74 SOLAS (14CONS) CH I / Reg 8(b)(iii) 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 16 September 2019
Resolution: Surveyors were informed of inspection criteria for dry powder charges.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 September 2019 Resolved
07108- Fire extinguishers shall be situated ready for use. PSCO observed a fire extinguisher next to the oil water separator whose pointer on pressure indicator was on white, indicating no pressure. As per Kidde maker’s instructions, an extinguisher with a pointer not on green pressure indicator is not ready for use. PSCO observed 8 Kidde fire extinguishers in the engine room, 1 Kidde fire extinguisher on the bridge, 1 Kidde fire extinguisher in the A-Deck passage way near the galley, and 1 Kidde fire extinguisher in the starboard lifeboat whose pressure indicators were on red. 74 SOLAS (04CONS) CH II-2 / Reg 10.3.2.4 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 16 September 2019
Resolution: Crew replaced all non-ready for use extinguishers with ready for use extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2019 Resolved
07110- Spare charges shall be provided for 100% of the first 10 extinguishers and 50% of the remaining fire extinguishers. The vessel is required to have 31 5 kilogram fire extinguishers on board the vessel as noted on Fire Control Plan. In addition, the vessel is required to carry 21 spare 5 kilogram fire extinguishers or charges. 8 of the required fire extinguishers onboard were Yamato brand and 23 of the required extinguishers were Kidde. The spare charges on board are only for Yamato fire extinguisher model SA-17NR and were manufactured in August 2009. The validity of the Yamato spare charge is five years per maker’s instructions. The vessel had zero spare extinguishers or charges for the Kidde brand fire extinguishers on board. All spare charges are expired, thus the vessel has zero spare charges or spare extinguishers on board. 74 SOLAS (04CONS) CH II-2 / Reg 10.3.3.1 30ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 16 September 2019
Resolution: Vessel purchased full complement of extinguishers and spares
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2019 Resolved
07106- The function of fixed fire detection systems shall be periodically tested by means of equipment producing hot air at the appropriate temperature. During the exam, PSCO observed crew was testing heat detector with a lighter, in which crew could not prove was the appropriate temperature for heat detectors installed on vessel. 74 SOLAS (04 CONS) CH II-2 / Reg 7.3.2 30ABC
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 16 September 2019
Resolution: Crew now uses appropriate testing equipment
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 September 2019 Resolved
14119- Means shall be provided to control leaks of flammable liquids. PSCO observed main engine cylinders 1, 2, 3, and 6 were leaking fuel oil from the high-pressure fuel pumps. Evidence of excessive leaking was found in the engine room. Diesel-soaked rags were found around the cylinders, unapproved plastic collection pans were installed for excessive diesel oil leaks creating a fire hazard, and the decking in the engine room near diesel leaks was slippery from the fuel. 74 SOLAS (04CONS) CH II-2 / Reg 4.1.1 30 ABC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 16 September 2019
Resolution: Crew replaced all gaskets on fuel lines from high pressure fuel pump and cleaned and properly disposed of all excess fuel and rags.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 12 September 2019 Resolved
14107- The system shall be provided with arrangements to ensure that any discharge of oily mixture is automatically stopped when the oil content of the effluent exceeds 15 ppm. During the exam, PSCO observed the three-way valve controlling the overboard discharge did not operate and stayed in the discharged overboard position after the oil content displayed 15 ppm and higher. MARPOL 73/78 ANNEX I / Reg 14.7 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2019
Resolution: Three-way valve was was able to turn via solenoid.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 12 September 2019 Resolved
14503- Every ship of 100 gross tonnage and above, shall carry a garbage management plan which the crew shall follow. During deck walk, PSCO observed approximately 3 cubic meters of garbage located between cargo holds 3 and 4. Area where garbage was stored is not an authorized location as per the vessel’s garbage management plan. MARPOL 73/78 ANNEX V / Reg 10.2 17C
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2019
Resolution: Vessel discharged garbage appropriately to shoreside facility.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 September 2019 Resolved
07120- The CSO must ensure consistency between security & safety requirements. The escape route from the steering gear room to the main deck is secured from the inside with no means of access from the outside. MSC Cir. 1120, unified interpretation 13.3.3 states locking arrangements for escape routes should be such that it does not obstruct escape and access. The emergency escape route from the main deck to the steering gear room is secured from the inside of the vessel by means of a latch and only able to be opened from inside of the vessel. 74 SOLAS (04CONS) CH II-2 / Reg 13.3.3 ISPS Code Part A Reg 11.2.11 50 AC
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2019
Resolution: Latch from inside of the vessel was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2019 Resolved
07199- Flammable liquid lockers shall be protected by an appropriate fire extinguishing arrangement approved by the Administration. PSCO observed eight flammable aerosol cans located in a storage locker with no fire extinguishing arrangements. 74 SOLAS (04CONS) CH II-2 / Reg 10.6.3.2 10C
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 12 September 2019
Resolution: Vessel removed aerosol cans from improper location and into designated space for flammable storage.
Fire Fighting › Portable Foam Applicators › General
Issued 12 June 2016 Resolved
0730 - Fire fighting appliances (general) - Firefighting appliances shall be kept in good working order and readily available for use. Two (2) 45-liter portable foam applicators had not been properly serviced. Last service date shown as December 2014. - SOLAS 74 (2009 Cons. Ed.) II-2/14.2.1.2. - 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 12 June 2016
Resolution: Deficiency rectified on-the-spot.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 June 2016 Resolved
1720 - Control of discharge of oil - There are clear grounds that the crew is not familiar with essential shipboard procedures relating to the prevention of pollution by oil. Crew was unable to demonstrate proper operation of oil content meter recording function. - MARPOL 2011, Annex I/11.1 - 10c.
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 12 June 2016
Resolution: Deficiency cleared on-the-spot.

Ownership record