MAURY USCG vessel records Sign in
← All vessels

GREEN OAK

GREEN OAK is a 2008 tank ship. The Coast Guard has recorded 9 inspections since 2009, most recently in September 2015, along with 14 deficiencies and 3 operational controls.

Records from 2009 to 2015. Most recent: inspection, 30 September 2015.

Built
2008
Last inspected
30 September 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9439319 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1050699
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1050699

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2009–2015)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4117 - Convention (Subpart B), Net Ton
8539 - Convention (Subpart B), Gross Ton
13044 - Dead Weight, Metric Ton
17472 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

30 September 2015 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5732366
15 December 2011 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4207427
23 February 2011 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3950669
21 December 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3912943
21 December 2010 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3914460
24 November 2010 Ballast Water Examination · ISPS I Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896387
23 October 2010 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3876990
20 March 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3696566
20 December 2009 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3649122

Deficiency record · 14

Engineering › Sea-water System (primary cooling) › Piping
Issued 30 September 2015 Resolved
1400; The machinery, boilers and other pressure vessels, associated piping systems, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The following were found with leaks: Shaft bearing leaking oil; #1 and #2 main and See Narrative.
Condition: Improper/Lack of Maintenance
Due 30 September 2015
Resolved 30 September 2015
Resolution: Addressed and repaired to the satisfaction of the attending Classification and Flag State Representatives.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 30 September 2015 Resolved
2540; The training manual shall contain instruction and information on the life-saving appliances provided in the ship. Survival craft portions of he training manual includes equipment not provided on board, 74 SOLAS (14) III/35.3, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Corrected to the satisfaction of Class and Flag Representatives.
Operations/Management › Drills/Instruction › Fire
Issued 30 September 2015 Resolved
0799; The Safety Management System shall be maintained in accordance with the provision of the ISM Code. Instruction provided for operating fixed foam fire suppression system are not ship specific and are conflicting with printed instructions. In addition 02 contend checks of tanks times are not recorded, 74 SOLAS (14) IX/5, ISM Code A/10, 10 C.
Condition: Improper/Lack of Maintenance
Due 30 September 2015
Resolved 30 September 2015
Resolution: Corrected to the satisfaction of Class and Flag Representatives.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 30 September 2015 Resolved
2510; The safety Management System shall be maintained IAW the provision of the ISM Code. The MSD is not being maintained as per the manufacturer's requirements, 74 SOLAS (14) IX/5, ISM Code A/10, 33 CFR 159.121(b), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Corrected to the satisfaction of the Class and Flag Representatives.
Operations/Management › Pollution › Ballast Water Management
Issued 30 September 2015 Resolved
2525; The Master, owner operator or person in charge of the vessel must employ, install and operate a Ballast Water Management Plan including detailed fouling maintenance pan, 33 CFR 151.2050(g), MEPC 207(62), 10C.
Condition: Improper/Lack of Maintenance
Due 30 September 2015
Resolved 30 September 2015
Resolution: Corrected to the satisfaction of the Class and Flag Representatives.
Documentation › Logs/Records › Oil Record Book
Issued 30 September 2015 Resolved
1710; The Oil Record Book shall be in the form specified in Appendix III to this Annex. ORB part 1 is not being properly filled out. In addition, Cargo Record Book receipts for discharge of product do not match entries, MARPOL 1/17.1, MARPOL II/15.2, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Corrected to the satisfaction of Class and Flag Representatives.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 30 September 2015 Resolved
2535; The operator shall provide transfer procedures meeting the requirement of this part. Vessel's bunker or transer procedures do not meet the requirements of 155.750, 33 CFR 155.720, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Corrected to the satisfaction of Class and Flag Representatives.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 30 September 2015 Resolved
2550; The condition of the ship and its equipment shall be maintained to conform with the provisions of he present regulations to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. The incinerator does not appear to be burning as efficiently as intended and oil is passing through the door to the outside, 74 SOLAS !/11, 74 SOLAS 1/10, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Corrected to the satisfaction of Class and Flag Representatives.
Operations/Management › Pollution › Control of Garbage
Issued 30 September 2015 Resolved
2120; Every ship shall carry a Garbage Management Plan which the crew shall follow. Garbage is being mixed at the final collection point an appears to have been discharged overboard (food and non food items) 21 times since the last port as recorded in the Garbage Record Book, MARPOL V/10.3, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2015
Resolved 30 September 2015
Resolution: Addressed and corrected to the satisfaction of Class and Flag Representatives.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 December 2011 Resolved
1730-Oily Water Separating Equipment- PSCO noted ORB entries prior to 18 Oct 11 were not reflected in the OWS data logger. All ORB entries post 18 Oct 2011 were reflected in the OWS data logger. MARPOL 73/78 annex I/6
Action required: 705 - Other - as specified
Due 15 December 2011
Resolved 18 December 2011
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating the deficiency was rectified. Technician found faulty control board and sensing unit, Renewed and tested to the satisfaction of the class surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 December 2011 Resolved
1730- Oily Water Separator-Crew was unable to perform and operational test of OWS due to OCM, which displayed an "E14" error code.
Action required: 705 - Other - as specified
Due 15 December 2011
Resolved 18 December 2011
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating the deficiency was rectified. Technician found faulty control board and sensing unit, Renewed and tested to the satisfaction of the class surveyor.
Deck/Cargo › Holds/Tanks › Ullage
Issued 15 December 2011 Resolved
0750- Fire Protection-PSCO were unable to verify atmospheric condition of the port slop tank due to vacuum condition on the tank. Slop tank contains residue from last petroleum cargo, gasoline and low sulfur fuel oil,
Action required: 705 - Other - as specified
Due 15 December 2011
Resolved 18 December 2011
Resolution: Received, reviewed and accepted class report from Liberia stating the deficiency was rectified. Company was instructed to follow Fleet Handbook, Chapter 6.7 which requires tanks to be inerted and pressurized.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 December 2011 Resolved
1740-Oil Discharge Content Meter- Crew unaware of the OCM capabilities and unable to retrieve operational history from the OCM. -MARPOL 73/78 Annex I/11
Action required: 705 - Other - as specified
Due 29 December 2011
Resolved 18 December 2011
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating the deficiency was rectified. Class Society issued an OSR requiring engine room crew to receive training and demonstrate proper operation of OWS and OCM.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 21 December 2010 Resolved
While performing O2 Calibration on vessel's Inert Gas System (IGS) the O2 sensor malfunctioned and would not zero out. Vessel to make proper repaires and classifaction society to attest to proper operation of Inert Gas System O2 calibration System Prior to Operating IGS.
Action required: 705 - Other - as specified
Due 21 January 2011
Resolved 23 February 2011
Resolution: Received class report attesting that the O2 censor has been replaced and the deficiency has been rectified.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.