Records from 2016 to 2025. Most recent: inspection, 25 September 2025.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 October 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within
the protected space. Vessels pre-engineered system failed to secure the generators and the power ventilation.
46 CFR 181.420 (a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2025
Resolution: Tested fireboy shutdown, verified engines, generator and power ventilation operated successfully.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 October 2025
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order
and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Vessels life floats outside coatings were found to be sun damaged and brittle and the pennants were found to be brittle and falling apart.
46 CFR 185.700
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2025
Resolution: Replaced life floats. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 October 2025
Resolved
Electrical equipment exposed to the weather must be watertight. Vessels forward mast headlight had exposed wires.
46 CFR 183.210 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2025
Resolved 17 November 2025
Resolution: Exposed wires repaired appropriately. All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 27 August 2024
Resolved
Employee assistance programs must be conducted for the employer's crew members and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Supervisor does not have certificate of completion. Show completed course documentation to marine inspector upon completion.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 14 April 2025
Resolution: Received certificates proving supervisory training.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 August 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection machinery failure Steering system controls located in the pilot house were leaking hydraulic fluid at the helm. Make sufficient repairs to satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 9 September 2024
Resolution: Vessel rep corrected leak to satisfaction of Qualified MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 August 2024
Resolved
At each inspection for certification and at every other vessel inspection spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard. Engine room intake ventilation screens and generator air filter were found to be dirty restricting proper air flow. Remove debris from machinery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2024
Resolved 9 September 2024
Resolution: Vessel rep removed harzardous derbis to satisfaction of Qualified MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 August 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an
interconnected fire detection system in compliance with§ 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel was found without interconnected system installed in the accommodation and machinery space. Install approved UL217 detectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 27 December 2024
Resolution: Vessel installed approved UL217 detector, tested in presense of [name withheld].
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 December 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Lubricating oil lines on both port and stbd main engines were severely deteriorated. Replace lubricating oil lines for both engines.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: replaced flex hoses
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 December 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel was missing servicing record for fixed-gas fire extinguishing system.
46 CFR 176.810 (b)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 14 December 2022
Resolution: submitted photo evidence of servicing report
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2022
Resolved
Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant. Ring life buoy water lights battery was expired.
46 CFR 180.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 31 January 2023
Resolution: Received photo of proper unexpired light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 December 2022
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. 02 batteries from each life float were expired.
46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 31 January 2023
Resolution: Received photo of proper unexpired lights.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 December 2022
Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Spacers were missing between the two life floats.
46 CFR 180.137(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 9 December 2022
Resolution: added spacers to lifefloats
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 December 2022
Resolved
Each survival craft required on a vessel by this part must meet one of the following: For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. Retro-reflective tape on both life floats was deteriorated. Replace retro-reflective tape on both life floats.
46 CFR 180.200(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 14 December 2022
Resolution: replaced retro-tape
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 December 2022
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher in wheelhouse was not securely mounted.
46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 31 January 2023
Resolution: Received photo of properly mounted extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel had coolant leak on both port and stbd main engine. Correct prior to drydock certification.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 January 2023
Resolution: Leak addressed during Jan2023 drydock. Worn seal was identified and replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 December 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel had two through hull fittings that were uncapped both port and stbd in forward compartment, aft of collision bulkhead. Secure through hull fittings.
46 CFR 176.830(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 9 December 2022
Resolution: capped through hull fittings
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 December 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Battery box located port aft within engine room contained dead-end wires. Disconnect and remove dead-end wires from battery box.
46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 9 December 2022
Resolution: removed dead end wires
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 1 December 2022
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. Vessel was missing written garbage management plan.
33 CFR 151.57
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 9 December 2022
Resolution: submitted garbage management plan
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 December 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel had outdated charts on board.
46 CFR 184.420 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 14 December 2022
Resolution: provided photo evidence of new charts
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2020
Resolved
Vessels child life jackets do not have lights. Each life jacket carried on an oceans route must have lights. porivde evidence of properly secured lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2020
Resolved
At time of inspection, vessels port main engine did not operate. Machinery and equipment installed on each vessel but be suitable and maintained for proper and safe operation. Provide evidence of engine working satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 October 2020
Resolved
port rail aft of pilot house is not properly attached at the base. pails or equivalent protection must be installed properly near periphery of all accessible decks. secure rail to he deck to withstand 200lb point load.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 October 2020
Resolved
Identification plate for derated capacity of generator is not present. each motor must have name plate including such derated capacity. provide evidence of attached plate/information.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 November 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 October 2019
Resolved
Drills required every three months. Noted that frequency of drills conducted was once every four months. Conduct drills at appropritate intervals.
Action required: 10 - Deficiency Rectified
Due 21 November 2019
Resolved 29 October 2019
Resolution: Witnessed satisfactory drills
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 October 2019
Resolved
COI must be posted in a conspicuous place where observation of passengers is likely. COI not properly posted. Post all pages of COI in a conspicuous location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 21 November 2019
Resolution: COI is posted in conspicuous place where passengers are likely to view.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 29 October 2019
Resolved
Emergency broadcast instructions specific to vessel must be posted. Noted there was no specific instructions for SSB radio. Post appropriate instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 21 November 2019
Resolution: Emergency broadcast instructions specific to vessel SSB Radio are posted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 29 October 2019
Resolved
A vessel that carries more than one life float in a group may be secured by a single painter. Life floats not attached with single painter or independently mounted. Properly mount life floats. Route limited to Lakes, Bays, and Sounds until rectified.
Action required: 705 - Other - as specified
Due 21 November 2019
Resolved 4 February 2020
Resolution: Installed 02 new Jim-Buoy 12 person life floats under USCG Approval No. 160.027/80/2. The configuration of the life floats were verified to be installed and arranged with a single painter and in accordance with 46 CFR 180.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2019
Resolved
Each floating light must be attached to the lanyard with a corrosion resistant clip. Floating waterlight not attached to life ring buoy with clip. Attach with appropriate clip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 21 November 2019
Resolution: Floating Light is attached correctly with corrosion resistant clip and sufficient length of line to the life ring buoy.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 October 2019
Resolved
Public Address system was not broadcasting to all spaces in the same loop. Repair or replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 21 November 2019
Resolution: Public Address system was fixed and tested, satisfactory test
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Generator must be derated to 80 percent of full load and setting of overcurrent device reduced accordingly. Provide 80 amp breaker in the breaker panel for generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 21 November 2019
Resolution: Generator successfully de-rated to 80% of full load and setting overcurrent device reduced accordingly. 80 amp breaker for generator also provided.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 October 2019
Resolved
Vessel did not have 1 portable hand pump in accordance with 46 CFR 182.520(a). Provide appropriate hand pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2019
Resolved 22 November 2019
Resolution: See attached photo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2019
Resolved
Vessel on ocean route must have life jacket light. Vessel did not have any lights for the life jackets. Provide life jacket lights. Vessel route restricted to limited coastwise until rectified.
Action required: 705 - Other - as specified
Due 21 November 2019
Resolved 21 November 2019
Resolution: USCG approved Life Jacket lights provided.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 29 October 2019
Resolved
Check valve in bilge piping system failed and two others are inproperly installed. Repair or replace and properly install.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2019
Resolved 21 November 2019
Resolution: Check valves in bilge piping system were properly installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 October 2019
Resolved
Vessel Certificate of Inspection (COI) has passed their expiration date, rendering the COI as invalid. Vessel may not operate without a valid COI. The vessel may not operate until a COI inspection has been performed by a USCG Inspector and issued a new COI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2019
Resolved 29 October 2019
Resolution: Conducted satisfactory COI inspection on 29OCT19.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 September 2018
Resolved
A space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system. Repair turbo leak, reinstall fixed system and test ot the satisfaction of the attending Marine Inspector
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 December 2017
Resolved
Replace expired medicine in the medical chest.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Replaced expired medicine.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 December 2017
Resolved
Replace expired portable extinguisher in the Wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Replaced expired extinguisher.
Documentation › Logs/Records › Drug Test Records
Issued 14 December 2016
Resolved
Consortium letter did not have new crew member on list. Supervosory training was not conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 23 January 2017
Resolution: Verified consortium letter and supervisory training.
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 December 2016
Resolved
Steering lines missing proper holders.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 23 January 2017
Resolution: Verified that steering lines had proper holders.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 December 2016
Resolved
Missing marine radio permit for one captain.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 23 January 2017
Resolution: Verified marine radio permit that was missing for one Captain.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 December 2016
Resolved
DSC-VHF missing GPS capability.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 23 January 2017
Resolution: Verified that DSC-VHF GPS capability was properly installed.
Engineering › Fuel Oil Service System › Piping
Issued 14 December 2016
Resolved
Fuel lines missing J1942 at fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 23 January 2017
Resolution: Verified that fuel filter was properly fitted with J1942 fuel line.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 December 2016
Resolved
Electric outlet in engine room missing cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 23 January 2017
Resolution: Verified that outlet in engine room was fitted with a proper cover.