HERCULES J is a freight ship. The Coast Guard has recorded 1 inspection in 2009, along with 1 deficiency.

Records in 2009. Most recent: inspection, 24 December 2009.

Built
Not recorded
Last inspected
24 December 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9430193 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1051128
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1051128

Inspections, by type

Years with a record 1 calendar year (2009)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5372 - Convention (Subpart B), Net Ton
10585 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

24 December 2009 Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3652533

Deficiency record · 1

Engineering › Freshwater Generation System › Pump
Issued 18 December 2009 Resolved
1499 The boiler feed water pumps required by SOLAS 74/78 Ch. I Reg.11 are inoperable. Prove proper operation of the boiler feedwater system prior to departure. Code 17c
Action required: 705 - Other - as specified
Due 24 December 2009
Resolved 26 January 2010
Resolution: Verified replacement and proper operation of both aux boiler feed water pumps. Verified proper operation of hot well low water sensor. Sensor malfunction led to pumps burning out originally.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.