Records from 2010 to 2023. Most recent: inspection, 5 May 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
5 May 2023
PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7677846
28 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7209142
24 April 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6668750
23 April 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6668767
15 April 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6662559
5 October 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6281292
4 August 2015
Ballast Water Examination · PII Safety Exam · Deficiency Check · Administrative Inspection · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5198752
15 February 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3680187
10 January 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3661929
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 May 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustable materials or flammable liquids. for this purpose, the following functional requirments shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaking from the sight glass assemble on the fuel injector on the #2 cylender head of the main diesel engine. 74 SOLAS (09) II-2/4.1.1
Action required: 10 - Deficiency Rectified
Due 5 May 2023
Resolved 5 May 2023
Resolution: PSCO observed the leak on the sight glass repaired.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 5 October 2017
Resolved
2510: Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel is not documenting sediment removal and maintenance records for Anti-Fouling and Bio-Fouling, 33CFR151.2050(g) 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2017
Resolved 5 October 2017
Resolution: Discussed Ballast and Bio-Fouling requirements with the Captain, [name withheld], [name withheld] and Chief Engineer.
Electrical › Electric Generation Source (emergency) › Generator
Issued 4 August 2015
Resolved
0999 - The emergency generator unexpectedly shut down during its OP test. The cause of the casualty was due to the fuel oil supply COV being in the closed position. As a result, the emergency generator was not ready for immediate use. 74 SOLAS (2004) II-1/42 10c
Due 4 August 2015
Resolved 4 August 2015
Resolution: Crew opened fuel oil COV and conducted another OP Test, Test SAT.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 4 August 2015
Resolved
0999 - Crew familiarity in regards to diagnosing the casualty on the emergency generator was less than satisfactory. After several minutes, they were unable to identify the cause of the emergency generator's shutting down. The PSCO had to intervene and point out the source of the casualty to the crew; which was a closed F/O COV (supply side). 74 SOLAS (2014) XI-1/4 17b
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2015
Resolved 7 August 2015
Resolution: Received Class Report attesting to the corrective actions regarding this def.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 4 August 2015
Resolved
0750 - Discovered L/O leaks coming from the sight glasses for the M/E L/O Storage Tank and the SSGD L/O storage Tank. Leaks were steady and a combined accumulation of 1 gallon of L/O drippings were discovered in the bilge. 74 SOLAS (2019) II-2/4.1.1 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2015
Resolved 7 August 2015
Resolution: Received Class Report attesting to the repairs of the L/O leaks.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 4 August 2015
Resolved
0750 - Discovered that lower portion of insulation covering the F/O Storage Tank was saturated with F/
O. This condition poses a threat to the safety of the vessel and crew. 74 SOLAS (2009) II-2/4.1.3 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2015
Resolved 7 August 2015
Resolution: Received Class Report attesting the satisfactory repairs.
Engineering › Steam System (auxiliary) › Piping
Issued 4 August 2015
Resolved
0999 - discovered inner lining of boiler's cascade tank was heavily saturated with oil deposits, as well as oil contaminants floating of the water's surface. 74 SOLAS (2014) I/11(a) 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2015
Resolved 7 August 2015
Resolution: Receive Class report attesting to the repairs.