MAURY USCG vessel records Sign in
← All vessels

ISLE OF KAMEEL

ISLE OF KAMEEL is a 1969 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1985, most recently in July 2012, along with 123 deficiencies.

Records from 1985 to 2012. Most recent: inspection, 9 July 2012.

Built
1969
Last inspected
9 July 2012
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBE4594
105188
Flag
UNITED STATES
367171980 (licence lapsed)
Maury page id
psix-105188

Inspections, by type

…with no type recorded13
Years with a record 28 calendar years (1985–2012)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)52.3 ft × 12.0 ft × 3.6 ft
Registered tonnagegross 41 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARRI-CRAFT INC · BERLIN, WI, UNITED STATES · built 1969
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDALLAS, TX
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBE4594MMSI 367171980 · expired · compulsorily equipped · granted 9 March 2007, cancelled 13 May 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 74

9 July 2012 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4375349
4 June 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4333486
15 May 2012 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4321630
5 January 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4218563
26 September 2011 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4154869
23 February 2010 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3684778
9 March 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3426870
28 February 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3153116
12 June 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2955523
12 June 2007 Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2966060
18 May 2007 Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2958691
31 May 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2666674
20 March 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2603526
20 June 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2354230
9 March 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2307244
31 January 2005 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2283715
5 May 2004 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2060150
29 March 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2034057
3 June 2003 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1798582
28 April 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779345
17 March 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740399
15 March 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1494152
20 June 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413974
26 March 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1463642
2 March 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1372957
1 July 1999 Hull Examination · Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365274
23 June 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 140037
23 June 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 231726
22 March 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1471186
13 May 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790432
9 April 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1436074
14 July 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1414832
4 April 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1390489
28 March 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1077980
30 August 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 883128
22 August 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 878482
13 April 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1176000
17 November 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866641
3 May 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858030
5 April 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 855690
10 December 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159941
29 April 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 837111
6 April 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1149411
15 January 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 827448
15 December 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1136076
11 December 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831457
1 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830507
30 November 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 826604
14 November 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1136128
10 July 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 950464
18 May 1992 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257413
2 May 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 906418
9 April 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996912
5 April 1991 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1237287
29 June 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 912976
18 April 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900260
6 April 1990 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1223980
20 February 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1238686
18 April 1989 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1199974
29 March 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1201273
12 August 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1344459
7 May 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1347431
8 April 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996005
28 December 1987 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1022684
5 August 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1029730
11 April 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330175
8 April 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330418
1 April 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018887
26 September 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004729
18 April 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312533
15 June 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1294312
19 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1292210
8 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 980629
3 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 979942

Deficiency record · 123

Engineering › Fuel Oil Service System › Piping
Issued 4 June 2012 Resolved
Remove wasted fuel tank fill pipes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 9 July 2012
Resolution: Removed all unusable tank fill pipes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2012 Resolved
Remove or properly dead end wires in stbd tank room, under pilot house operating station, Port CO2 space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 22 February 2018
Resolution: Deficiency cleared, vessel will have to undergo full COI prior to re-entering service (vessel has been laid up since 2012).
Engineering › Fuel Oil Service System › Piping
Issued 4 June 2012 Resolved
Cap fuel lines in stbd tank room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 9 July 2012
Resolution: Fuel lines are capped.
Engineering › Fuel Oil Service System › Piping
Issued 4 June 2012 Resolved
Properly identify both fill screw caps for diesel fuel tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 9 July 2012
Resolution: Both screw caps were properly identified.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed proof of MIS submission.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed copy of updated consortium contract.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 January 2012 Resolved
Provide new iodine applicator for onboard first aid kit.
Action required: 705 - Other - as specified
Due 5 February 2012
Resolved 10 February 2012
Resolution: New iodine applicators were purchased and placed on the vessel.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 January 2012 Resolved
properly dead end wire in the portside water heater space.
Action required: 705 - Other - as specified
Due 5 February 2012
Resolved 10 February 2012
Resolution: Properly dead ended the wire and eliminated a possible electrical hazard.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 5 January 2012 Resolved
Properly display the name and home port on the stern of the vessel.
Action required: 705 - Other - as specified
Due 5 February 2012
Resolved 10 February 2012
Resolution: The company ordered new stickers and properly arranged the name of the vessel and hailing port on the stern.
Stability › Incline Test › General
Issued 5 January 2012 Resolved
Conduct a stability test for a catamaran vessel.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 8 March 2012
Resolution: This vessel is permitted to use the weight ratio method to be in compliance with the new stability regulations.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 June 2011 Resolved
Complete an annual inspection prior to carrying passengers for hire.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2012
Resolution: Completed annual examination.
Engineering › Bilge Water Management System › Strainer
Issued 4 March 2010 Resolved
Provide strainer for bilge suction line in the port side engine room.
Due 5 April 2010
Resolved 7 April 2010
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 4 March 2010 Resolved
Repair/replace overhead lagging for the generator space.
Due 5 April 2010
Resolved 7 April 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 4 March 2010 Resolved
Provide lagging for turbo and replace exhaust elbow on the stbd MDE.
Due 5 April 2010
Resolved 7 April 2010
Lifesaving › Lifebuoys › Serviceable
Issued 4 March 2010 Resolved
Replace lifering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2010
Lifesaving › Lifefloat › Serviceable
Issued 4 March 2010 Resolved
Repair or remove extra 10 person lifefloat.
Due 5 April 2010
Resolved 7 April 2010
Resolution: Removed lifefloat and re-arranged weak link arangement to match the new set up.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 4 March 2010 Resolved
Prove proper operation of fuel oil shut-off valve for the port main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2010
Resolved 5 March 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 March 2010 Resolved
Provide seperation for child and adult jackets on the main deck.
Due 5 April 2010
Resolved 7 April 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 9 March 2009 Resolved
Repair/replace lighting fixture in stbd ER (globe filled w/water & hanging by cable).
Due 30 April 2009
Resolved 9 March 2009
Lifesaving › Lifefloat › Painter
Issued 9 March 2009 Resolved
Properly arrange life float painters to allow for float free operation.
Due 16 March 2009
Resolved 9 March 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 9 March 2009 Resolved
Remove partially discharged extinguisher from storage closet. (This was in addtion to req'd number of extinguishers, so no replacement is req'd).
Due 16 March 2009
Resolved 9 March 2009
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 28 February 2008 Resolved
Prove proper operation of natural ventilation vent closures for both port and stbd engine room spaces in accordance with 46CFR 181.20-35.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2008
Lifesaving › Lifefloat › Float Free
Issued 28 February 2008 Resolved
Make port BA's float free in way of painter line.
Action required: 705 - Other - as specified
Resolved 28 February 2008
Documentation › Logs/Records › Drug Test Records
Issued 11 June 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently enrolls new employees in its contracted drug testing consortium on a quarterly basis, rather than at the time of hiring.
Due 5 July 2007
Resolved 12 June 2007
Resolution: New employee''s names will be added to the company''s consortium''s random drug testing list prior the employee acting in a safety sensitive position.
Documentation › Logs/Records › Drug Test Records
Issued 11 June 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently is waiving random drug testing for some employees, based upon their participation in another unaffiliated company.
Due 5 July 2007
Resolved 12 June 2007
Resolution: Random drug tests will no longer be waived.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 March 2006 Resolved
Prove proper operation of fixed CO2 fire extinguishing system for both engine rooms
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Fire Fighting › Ventilation Systems › Operating Controls
Issued 16 March 2006 Resolved
Prove proper operation of ventilation shutdowns for engine rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 16 March 2006 Resolved
Permanently mount all electronic bilge pumps and high level alarms in all compartments.
Due 20 April 2006
Resolved 31 March 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 March 2006 Resolved
Remove twist on type connector in port engine room next to marine gear.
Due 20 April 2006
Resolved 31 March 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 March 2006 Resolved
Permanently mount electrical junction box, port engine room forward of marine gear.
Due 20 April 2006
Resolved 31 March 2006
Stability › Watertight Integrity › General
Issued 16 March 2006 Resolved
Make port and stbd forward engine room bulkheads watertight.
Due 20 April 2006
Resolved 31 March 2006
Stability › Watertight Integrity › General
Issued 16 March 2006 Resolved
Make port and stbd transom pipe penetrations watertight in way of engineroom.
Due 20 April 2006
Resolved 31 March 2006
Lifesaving › Lifefloat › Platform
Issued 16 March 2006 Resolved
Install spacers between Buoyant apparatus IAW: 46 CFR 180.137
Due 20 April 2006
Resolved 31 March 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 March 2005 Resolved
Provide an additional 3 Type I Adult PFD's and properly store on vessel. Vessel is restricted to carry a maximum of 78 passengers for hire when vessel is operating on a Rivers Route.
Due 30 April 2005
Resolved 20 June 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 28 February 2005 Resolved
Relabel starboard PFD stowage locker in way of the bow area from 14 passengers to 12 passengers for adult PFD's.
Due 30 April 2005
Resolved 20 June 2005
Lifesaving › Lifefloat › Float-free Link
Issued 28 February 2005 Resolved
Install proper weak-link on port side life floats, (from 11-20 pax to 21 + pax).
Due 28 February 2005
Resolved 28 February 2005
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 February 2005 Resolved
Prove proper operation of generator remote F/O valve in way of stbd F/O tank, in board of engineering space.
Due 28 February 2005
Resolved 28 February 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 28 February 2005 Resolved
Prove proper operation of stbd eng. room bilge high leverl alarm.
Due 28 February 2005
Resolved 28 February 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2005 Resolved
Properly dead-end electrical wire in way of stbd eng. space, inboard.
Due 28 February 2005
Resolved 28 February 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 28 February 2005 Resolved
Replace compression wire nuts on dead-ended electrical cable in stbd generator space.
Due 28 February 2005
Resolved 28 February 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 28 February 2005 Resolved
Tighten loose screws on box cover for fire pump control switch.
Due 15 March 2005
Resolved 9 March 2005
Engineering › Bilge Water Management System › Not Operational
Issued 28 February 2005 Resolved
Prove proper operation of bilge system throughout vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2005
Resolved 16 March 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 March 2004 Resolved
Make engineroom bulkhead(s) vapor tight.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 28 February 2005
Construction/Loadline › Structures › Deck Plating
Issued 29 March 2004 Resolved
Submit plans for approval to repair galley Deck in way of port side Accommodation space from forward bulkhead of head, extending aft to the forward edge of the bar and extenting from skin of vessel inboard approximately 5 feet.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 28 February 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 March 2004 Resolved
Re-secure and properly cover with applicable cover the electrical recepticle in way of the forward fresh water tank void space.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 28 February 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 29 March 2004 Resolved
Submit plans for approval to properly wire galley exhaust hood.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 28 February 2005
Resolution: Removed galley hood.
Electrical › Electric Supply System (service) › Cable
Issued 29 March 2004 Resolved
Provide proper cover for electric Bilge Controller box in way of port bulkhead outboard of reefer.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 28 February 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 March 2004 Resolved
Provide suitable storage for child lifejackets in way of lower accomodation space lifejacket storage.
Action required: 705 - Other - as specified
Due 29 March 2004
Resolved 29 March 2004
Resolution: Child lifejackets were properly stored and segrated and labeled.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 29 March 2004 Resolved
Replace port main engine raw water suction and discharge hose.
Action required: 705 - Other - as specified
Due 29 March 2004
Resolved 29 March 2004
Resolution: Replacement hose meets 46 CFR part 182.115 & 420 the hose is USCG approved marine exhaust hose.
Construction/Loadline › Penetrations › Valve Flange
Issued 29 March 2004 Resolved
Replace wasted metal retainer ring in way of port forward void space sink over board discharge.
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 28 February 2005
Construction/Loadline › Penetrations
Issued 3 June 2003 Resolved
Renew port side aft compartment 1.5" ball valve for fire pump. LEGACY COMPONENT DESC: Valve Flange
Action required: 705 - Other - as specified
Due 9 June 2003
Resolved 9 June 2003
Resolution: Ball valve renewed.
Construction/Loadline › Penetrations
Issued 3 June 2003 Resolved
Renew stbd side forward compartment 1.5" ball valve for sink discharge. LEGACY COMPONENT DESC: Valve Flange
Due 9 June 2003
Resolved 9 June 2003
Resolution: Ball valve renewed.
Construction/Loadline › Penetrations › Valve Flange
Issued 3 June 2003 Resolved
Install check valve for port side sink discharge line located below dishwasher.
Due 9 June 2003
Resolved 9 June 2003
Resolution: Valve installed.
Construction/Loadline › Hull › Stringer
Issued 3 June 2003 Resolved
Provide repair proposal for approval and make repair to portside stringer located under appliances. (Stringer separated from hull and forward bulkhead in compartment.)
Due 9 June 2003
Resolved 9 June 2003
Resolution: Repair made.
Construction/Loadline › Structures
Issued 3 June 2003 Resolved
Provide repair proposal for approval and make repair to portside inboard vertical frame located under the bar. (Approx 18" of delamination).
Due 9 June 2003
Resolved 9 June 2003
Resolution: Repair made.
Construction/Loadline › Hull › Side Shell
Issued 3 June 2003 Resolved
Fill all screw holes on inboard side of hull (chalked 3 areas) and check screw located in way of port side fuel compartment for weepage.
Due 9 June 2003
Resolved 9 June 2003
Resolution: Screw holes filled.
Documentation › Certificates/Documents
Issued 28 April 2003 Resolved
Show proof of a new Safety Radio Telephone Certificate. LEGACY COMPONENT DESC: Safety Radio Certificate
Due 30 June 2003
Resolved 9 June 2003
Resolution: New Safety Radio Certificate provided.
Navigation › Collision/Grounding Avoidance
Issued 17 March 2003 Resolved
Prove proper operation of forward masthead light. Vessel is restricted to operating at times specified in Rules of the Road until light is fixed. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 28 April 2003
Resolution: Masthead light works.
Engineering › Bilge Water Management System
Issued 17 March 2003 Resolved
Provide a portable bilge pump onboard vessel prior to carrying more than 49 passengers. LEGACY COMPONENT DESC: Portable bilge pump
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 28 April 2003
Resolution: A portable pump is onboard.
Stability › Severe Wind/Roll
Issued 17 March 2003 Resolved
Vessel is restricted to carrying no more than 60 passengers on Lakes, Bays, and Sounds Route IAW Stability Letter. LEGACY COMPONENT DESC: Stability Test
Due 17 June 2003
Resolved 28 April 2003
Resolution: COI modified to 60 total passengers on L,B,&S.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 17 March 2003 Resolved
Provide an approved portable fire extinguisher for topside accommodation space.
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 28 April 2003
Resolution: An approved fire extinguisher was provided.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 17 March 2003 Resolved
Provide machinery guards for rotating belts on both engines and generator. LEGACY COMPONENT DESC: Machinery Guards
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 28 April 2003
Resolution: Machinery guards provided for both engines and generator.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 17 March 2003 Resolved
Prove proper operation of auxiliary generator. LEGACY COMPONENT DESC: Operation
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 28 April 2003
Resolution: Generator works.
Electrical › Electrical Distribution System (service)
Issued 17 March 2003 Resolved
Properly cap or remove all dead end wiring located port side by fuel tank, on masthead near life floats, in closet under bridge, and near water heater in port bilge. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 28 April 2003
Resolution: All dead end wiring identified was capped.
Operations/Management › Equipment Service/Testing
Issued 17 March 2003 Resolved
Repair wasted mount for carbonator (used by bartender for beverages) located in port bilge, it has wasted and carbonator is unstable.
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 28 April 2003
Resolution: New mount was provided.
Operations/Management › Pollution
Issued 17 March 2003 Resolved
Provide means to prevent direct overboard discharge of food waste from garbage disposal to ensure compliance with MARPOL V. Food waste may not be discharged overboard in SF Bay. LEGACY COMPONENT DESC: Removal Methods/Procedures
Action required: 705 - Other - as specified
Due 17 May 2003
Resolved 3 June 2003
Resolution: Installed strainer so that no food would go down drain.
Lifesaving › Buoyant Apparatus
Issued 17 March 2003 Resolved
Provide spacers for buoyant apparatus. LEGACY COMPONENT DESC: spacers
Due 17 March 2003
Resolved 17 March 2003
Lifesaving › Buoyant Apparatus
Issued 17 March 2003 Resolved
Provide an approved mounting bracket for waterlight on stbd buoyant apparatus. LEGACY COMPONENT DESC: Waterlight
Due 17 March 2003
Resolved 17 March 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 March 2003 Resolved
Replace expired aspirin in first aid kit. LEGACY COMPONENT DESC: First Aid Kit
Due 17 March 2003
Resolved 17 March 2003
Communications › Radio Communications
Issued 17 March 2003 Resolved
Provide an appropriate emergency broadcast placard located near radio. LEGACY COMPONENT DESC: Emergency Broadcast Placards
Due 17 March 2003
Resolved 17 March 2003
Engineering › Fuel Oil Service System › Tank
Issued 17 March 2003 Resolved
Clean up fuel located in bilge.
Due 17 March 2003
Resolved 17 March 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 17 March 2003 Resolved
Ensure all fuel hoses have appropriate metallic clamps on lines less than 30". LEGACY COMPONENT DESC: Hose
Due 17 March 2003
Resolved 17 March 2003
Navigation
Issued 9 April 1998 Resolved
Provide onboard an updated compass deviation card.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Unknown
Issued 22 August 1995 Resolved
RESECURE WATER TANK IN THIRD COMPARTMENT PORT SIDE.
Condition: Unknown
Due 22 September 1995
Resolved 30 August 1995
Electrical
Issued 22 August 1995 Resolved
HARDWIRE AND REMOUNT CARBONIZER IN THIRD COMPARTMENT PORT SIDE.
Condition: Unknown
Due 22 September 1995
Resolved 30 August 1995
Construction/Loadline
Issued 22 August 1995 Resolved
REMOVE FURRING AND TREAT WOOD IN OVERHEAD OF STBD ENGINE COMPARTMENT.
Condition: Unknown
Due 22 September 1995
Resolved 30 August 1995
Navigation
Issued 13 April 1995 Resolved
PROVIDE A CURRENTLY CORRECTED NAVIGATIONAL CHART OF THE OPERATING AREA IAW 46 CFR 185.20-35.
Condition: Unknown
Due 27 April 1995
Resolved 12 May 1995
Lifesaving
Issued 5 April 1994 Resolved
MAKE REPAIRS TO SMALL HOLES ON BUOYANT APPARATUS' AND RE-STENCIL NAMES/CAPACITY.
Condition: Unknown
Due 19 April 1994
Resolved 3 May 1994
Lifesaving
Issued 5 April 1994 Resolved
PROVIDE TWO ADDITIONAL CHILD PFD'S. VESSEL RESTRICTED TO CARRYING 62 PASSENGERS/70 PERSONS UNTIL ADDITIONAL PFD'S ARE PROVIDED.
Condition: Unknown
Due 19 April 1994
Resolved 3 May 1994
Engineering
Issued 6 April 1993 Resolved
INSTALL AN EMERGENCY FUEL SHUT-OFF VALVE REACH ROD FOR THE STBD MAIN DIESELENGINE.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Fire Fighting
Issued 11 December 1992 Resolved
VESSEL IS TO BE OPERATED WITH (2) ADDITIONAL B-II FIRE EXTINGUISHERS UNTIL VESSELS' FIXED CO2 SYSTEM HAS BEEN SERVICED. THE SYSTEM MUST BE SERVICED TO THE SATISFACTION OF THE [name withheld] 14 DEC 92.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Deck/Cargo
Issued 30 November 1992 Resolved
PROVIDE SUFFICIENT AMOUNT OF ANCHOR LINE, 300FT.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Navigation
Issued 30 November 1992 Resolved
PROVIDE FOR INSPECTION PROPERLY INSTALLED RUDDER.
Condition: Unknown
Due 1 December 1992
Resolved 3 December 1992
Navigation
Issued 14 November 1992 Resolved
MAKE AVAILABLE FOR INSPECTION THE PROP AND SHAFT OF THE STBD ENGINE AND THEUNDERSIDE OF THE VESSEL.
Condition: Unknown
Due 14 November 1992
Resolved 14 November 1992
Fire Fighting
Issued 18 May 1992 Resolved
PROVIDE HYDROTEST RESULTS TO COAST GUARD INSPECTIONS OFFICE FOR FIXED CO2 SYSTEM.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Lifesaving
Issued 5 April 1991 Resolved
REPLACE ALL PERIMETER LINES, GRAB LINES, AND WATERLIGHT LINES ON EACH BOUYANT APPARATUS PER SUBCHAPTER "T".
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Lifesaving
Issued 5 April 1991 Resolved
REPLACE 1 FLOAT FREE WEAK LINK WHICH IS RUSTED THROUGH.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Lifesaving
Issued 5 April 1991 Resolved
PROVIDE RETRO-REFLECTIVE TAPE ON ALL BOUYANT APPARATUS.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
INSTALL NON-COMBUSTIBLE VENT DUCTING FROM EXTERIOR VENT TO FUEL TANK VENT SPACE, BOTH PORT AND STARBOARD.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Lifesaving
Issued 5 April 1991 Resolved
REPLACE LIFE RING AS LINE IS DETERIORATED.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Lifesaving
Issued 5 April 1991 Resolved
REPLACE STEEL CLIPS ON LIFE RING WATERLIGHT.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Construction/Loadline
Issued 5 April 1991 Resolved
MAKE FWD AND AFT BULKHEADS WATERTIGHT IN PORT FUEL TANK SPACE.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
REPAIR MALFUNCTIONING FLOAT SWITCH ON PORT FWD ELECTRIC BILGE PUMP.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Documentation
Issued 5 April 1991 Resolved
PROVIDE PLACARD THAT LIMITS TOTAL PASSENGERS ON UPPER DECKS (INCLUDING BOW)TO 38.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
SUPPLY LONGER HOSE FOR HAND FIRE/BILGE PUMP SO THAT ANY SPACE MAY BE PUMPED.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
COVER OR REMOVE INOPERATIVE FUEL GUAGES WHICH HAVE BEEN REPLACED WITH SOUNDING TUBES.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Lifesaving
Issued 5 April 1991 Resolved
PROVIDE 2 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Documentation
Issued 6 April 1990 Resolved
RENEW EXPIRED RADAR OBSERVER ENDORSEMENT.
Condition: Unknown
Due 6 April 1990
Resolved 6 April 1990
Accommodation/Occupational Safety
Issued 6 April 1990 Resolved
REPAIR FORWARD MOUNTING STRAP ON FORWARD FRESH WATER TANK.
Condition: Unknown
Due 6 April 1990
Resolved 6 April 1990
Electrical
Issued 18 April 1989 Resolved
PROVIDE GUARDS ON ENGINE SPACE LIGHTING.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Engineering
Issued 18 April 1989 Resolved
PROVE OPERATION OF ENGINE DRIVEN BILGE PUMP FROM GENERATOR SPACE.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Navigation
Issued 18 April 1989 Resolved
DRILL AND COTTER PIN STEERING GEAR CONTROL LINKAGES.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Engineering
Issued 18 April 1989 Resolved
REPAIR EXHAUST AND WATER LEAK ON STBD ENGINE IN WAY OF WATER INJECTION INLET TO EXHAUST.
Condition: Unknown
Due 18 April 1989
Resolved 18 April 1989
Construction/Loadline
Issued 29 March 1989 Resolved
REMOVE RUB RAIL FROM BOW AND REPAIR CRACK WHERE HULL AND DECK ARE GLASSED TOGETHER, STARTING ON PORT SIDE. HULL AND DECK ARE TO BE GLASSED TOGETHER.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 8 April 1988 Resolved
REPLACE WASTED FUEL VENT SCREENS WITH 30X30 MESH.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Lifesaving
Issued 8 April 1988 Resolved
MOUNT EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Lifesaving
Issued 8 April 1988 Resolved
REPLACE WORN PENNANT LINES ON PORT UPPER BUOYANT APPARATUS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Lifesaving
Issued 8 April 1988 Resolved
REPLACE WORN MAN LINES ON BOTH PORT BUOYANT APPATUS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Lifesaving
Issued 8 April 1988 Resolved
REPLACE WORN TAG LINE ON RING BUOY.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Engineering
Issued 8 April 1988 Resolved
PROVIDE GUARD AROUND PORT ENGINE BELT DRIVEN PUMP.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Engineering
Issued 8 April 1987 Resolved
REPACK STARBOARD SHAFT.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Lifesaving
Issued 8 April 1987 Resolved
REPAIR RUBBER COATING ON ONE (1) BUOYANT APPARATUS.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Engineering
Issued 8 April 1987 Resolved
REISTALL AND PROVE OPERATION OF ELECTRIC VENT FAN IN E/R OR REMOVE.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Construction/Loadline
Issued 1 April 1987 Resolved
SUBMIT PLANS FOR REMOVAL OR REPAIR OF RUB-RAIL.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Engineering
Issued 1 April 1987 Resolved
REPAIR FUEL TANKS (3) TO PREVENT LEAKAGE FROM PIPE FITTINGS.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Unknown
Issued 8 April 1985 Resolved
INSTALL ENGINE COMPARTMENT VENT DUCTS EXTENDING TO NEAR THE BILGE CONSTRUCTED OF RIGID FIREPROOF MATERIAL.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Lifesaving
Issued 8 April 1985 Resolved
REARRANGE PRESENT BUOYANT APPARATUS ARRANGEMENT SO AS TO BE FLOAT-FREE OR PROVIDE A SECOND SEAPAINTER AND BREAKLINK ASSBLY AND ATTACH TO THE SINGLE BUOYANT APPARATUS.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Electrical
Issued 8 April 1985 Resolved
INSTALL COVER OR SCREEN OVER BATTERIES IN THE GENERATOR COMPARTMENT.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Engineering
Issued 8 April 1985 Resolved
INSTALL FLAME SCREENS IN FUEL TANK VENTS.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Engineering
Issued 8 April 1985 Resolved
REMOVE RUBBER HOSE PORTION OF VENT PIPES AND REPLACE WITH PIPE OR COPPER TUBING FUEL TANK VENT LINES.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Engineering
Issued 8 April 1985 Resolved
REMOVE CORROSION FROM FUEL FILL PIPE IN ENGINE COMPARTMENTS.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Unknown
Issued 8 April 1985 Resolved
REMOVE OIL FROM BILGES
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Engineering
Issued 8 April 1985 Resolved
AFTER OIL IS REMOVED FROM BILGES OPERATIONALLY TEST BILGE PUMPS WITH COAST GUARD INSPECTOR WITNESSING.
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.