← All vessels
TORM CAVATINA
TORM CAVATINA is a 2010 tank ship. The Coast Guard has recorded 27 inspections since 2016, most recently in September 2025, along with 4 deficiencies and 3 operational controls.
Records from 2016 to 2025. Most recent: inspection, 24 September 2025.
- Built
- 2010
- Last inspected
- 24 September 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9343209
OZFZ2
1052321
Flag
DENMARK
Maury page id
psix-1052321
Inspections, by type
…with no type recorded6
Years with a record
10 calendar years (2016–2025)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it14168 - Convention (Subpart B), Net Ton
27061 - Convention (Subpart B), Gross Ton
46067 - Dead Weight, Metric Ton
57244 - Displacement, Metric Ton
27061 - Convention (Subpart B), Gross Ton
46067 - Dead Weight, Metric Ton
57244 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 27
24 September 2025
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8237357
17 September 2025
COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8236449
8 January 2025
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8060002
8 January 2025
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8064675
6 January 2025
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8059166
2 September 2024
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7994404
21 July 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7743043
26 January 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7386335
20 January 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7382880
25 September 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7320267
25 August 2021
COC-CHEM & TVE Renew
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7296648
19 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6980975
29 April 2020
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6937789
4 April 2019
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6651483
18 December 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6599776
25 June 2018
ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6452358
1 March 2018
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6362402
20 January 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6339672
6 August 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6231490
6 August 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6231643
21 March 2017
COC-CHEM & TVE Annual
Type not classified · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6103237
5 January 2017
ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6063256
28 October 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6031394
4 September 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5992238
24 February 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5821333
23 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5820558
16 February 2016
Ballast Water Examination · ISPS III Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5812115
Deficiency record · 4
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2025
Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored. Start air pressure was not sufficient to engage main engine.
74 SOLAS (04) II-1/26.3
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 April 2019
Resolved
General arrangement plans shall be exhibited for the guidance of ships officer, showing clearly for each deck the means of access to different compartments. PSC Officer observed partition wall installed between the mechanical workshop and electricians workshop not depicted on the fire control plan. Upper portion of the partition was of plywood material and not class approved.
74 SOLAS (04) II-2/15.2.4.1
50ac
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 April 2019
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the equipment and other items covered by the survey without the sanction of the Administration. PSC Officer observed A/C unit installed in the electricians workshop with no class approval. Wiring penetrated bulkhead affecting smoke boundary effectiveness.
74 SOLAS (14) I/11(b)
50ac
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 4 September 2016
Resolved
1735- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. A small hole in the bunker fuel pipeline caused a discharge of diesel fuel on to the deck of the vessel. 74SOLAS(14)I/11 40ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.