UACC SILA is a 2009 tank ship. The Coast Guard has recorded 5 inspections since 2016, most recently in September 2021, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2021. Most recent: inspection, 1 September 2021.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13435 - Convention (Subpart B), Net Ton 30006 - Convention (Subpart B), Gross Ton 49872 - Dead Weight, Metric Ton 60722 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
1 September 2021COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301790
15 March 2019Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6643031
11 March 2019COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6638797
1 July 2016Ballast Water Examination · COC-CHEM & TVE Renew · COE-Offshore · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5925609
29 June 2016Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5924156
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 March 2019Resolved
Maintenance, testing and inspection shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of the CO2 fixed gas extinguishing system. PSCO noted that the hydrostatic testing of 10 percent of the system's extinguishing agent/cylinders and pilot cylinders were not carried out.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 March 2019
Resolved 11 March 2019
Resolution: Harmonizing the 10 year hydrostatic testing of the CO2 cylinders with the vessel's drydock survey has been granted by the flag Administration, Marshall Islands.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 11 March 2019Resolved
Audible and visual alarms shall be provided for the inert gas system high pressure condition. Crew could not demonstrate the operation of the inert gas system high gas pressure alarm in the CCR. SOLAS 74 II-2/4.5.5.3.2 and FSS Code 15.2.2.4.5.1.1
Action required: 15 - Rectify deficiencies by next port
Resolved 15 March 2019
Resolution: Terminal block which transmit signal for the alarm of IG Deck Main Line High Pressure, was not making proper contact with IG Deck Main Line Pressure and O2 Content Recorder. Terminal block was secured properly and IG high pressure alarm was tested SAT.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2019Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to correct unless it is appropriare to the space concern. Two electric lighting fixtures located on the cargo deck are deteriorated and/or are compromized due to improper electrical connection terminations. SOLAS 74(04) II-1/45.10
Action required: 15 - Rectify deficiencies by next port
Resolved 15 March 2019
Resolution: Aft starboard explosion proof light fixture cable gland was re-installed to maintain explosion proof rating. Forward port explosion proof light fixture was renewed with spare fixture.
Documentation › Logs/Records › Oil Record Book
Issued 4 July 2016Resolved
1710-Oil Record Book- Oil tanker 150 gross tons and above is required to record in the oil record book each completed operation involving discharge overboard or disposal otherwise of bilge water. PSCO observed the oil content meter history display an active status along with alarm activations for several hours on 21Apr16 and 22Apr16.No log entry was completed. See attached 5437B.
Action required: 705 - Other - as specified
Due 4 July 2016
Resolved 4 July 2016
Resolution: Master and Chief Engineer was made aware of problem. Chief engineer was not part of crew during this time. Training was conducted with Eng department and Master.