SEAWAYS MYSTERY is a 2009 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in July 2026, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: operational control imposed, 24 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13134 - Convention (Subpart B), Net Ton 29293 - Convention (Subpart B), Gross Ton 44999 - Dead Weight, Metric Ton 56280 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
24 July 2026Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8445784
14 July 2026Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8437871
24 November 2025PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8272893
7 September 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8228742
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 October 2024Resolved
The venting system shall be provided with devices to prevent thte passage of flame into the cargo tanks. 08 of 12 cargo tank vents had holes in the flame screens.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2024
Resolved 15 October 2024
Resolution: Vessel replaced all defective flame screens prior to conclusion of exam
The international load line certificate shall not be delivered to the ship until the officer or surveyor acting under the provisions of Article 13 of the present convention has certified that the marks are correctly and permanetly indicated on the ships sides. the load line does not match with the international load line certificate or is not perman ently indicted on the ship sides. (ICLL REG 9) 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2019
Resolved 2 August 2019
Resolution: Class went on board and and verified crew made load line affixed with punch marks and load line matches their certificate.
Deck/Cargo › Cargo Stowage › General
Issued 20 June 2018Resolved
A chemical tanker shall comply with IBC code. Cargo samples should be cell divided in order to avoid shifting of bottles at sea. Cargo sample bottles were stowed unsecerly, not cell divided in order to avoid shifting of bottles at sea. 74 SOLAS (2014 cons) IBC code 16.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2018
Resolution: Master provided photographic documentation that the cargo samples have been properly cell- divided and secured to avoid shifting at sea.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 20 June 2018Resolved
Each vapor connection flange must have a permanent stud projecting outward. VCS connection flange studs were threaded and PSCO removed stud by hand. VCS stud required to be permanantly afixed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2018
Resolved 25 June 2018
Resolution: Master provided photgraphic evidence that the vapor studs have been permanently affixed.