← All vessels
AROSA
Freight Ship · Bulk Carrier class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named AROSA
AROSA is a 2009 freight ship. The Coast Guard has recorded 12 inspections since 2010, most recently in July 2025, along with 17 deficiencies and 1 operational control.
Records from 2010 to 2025. Most recent: inspection, 24 July 2025.
- Built
- 2009
- Last inspected
- 24 July 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9420265 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FQA3
1052621
Flag
LIBERIA
—
Maury page id
psix-1052621
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2010–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it18122 - Convention (Subpart B), Net Ton
30816 - Convention (Subpart B), Gross Ton
64444 - Displacement, Metric Ton
55477 - Dead Weight, Metric Ton
30816 - Convention (Subpart B), Gross Ton
64444 - Displacement, Metric Ton
55477 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
24 July 2025
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8189916
16 July 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8187476
18 August 2024
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7983859
21 June 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7711186
19 June 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7718519
12 March 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6925242
15 February 2019
PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6618677
20 November 2017
ISPS II Exam · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6305790
19 October 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5008015
18 October 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5004283
17 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5006783
27 January 2010
Ballast Water Examination · MARPOL Annex VI Survey · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3666645
Deficiency record · 17
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO witnessed fresh water supply to the water-mist system secured due to troubleshooting of leaking spray nozzle most likely due to faulty solenoid activation valve for boiler front area. SOLAS 74(a), II-2/14.2.1.2, Prior to Movement, Code 17
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 21 June 2023
Resolved
Whenever there is a hazardous condition either onboard a vessel or caused by a vessel or its operation, the owner, agent, master, operator, or person in charge must immediately notify the nearest Coast Guard Sector office or group office. Vessel failed to report inoperable emergency fire pump prior to arrival.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 20 November 2017
Resolved
The company should ensure that all personnel involved in company's SMS have an adequate understanding of relevant rules, regulations, codes, and guidelines. The ships senior officers failed to notify class when making modifications to vsl systems, were not using checklists as outlined in SMS, and failed to follow manufacturers instructions for testing shipboard equipment as evidences by deficiencies below.
Engineering › Lubricating Oil Service System › Tank
Issued 20 November 2017
Resolved
After any survey of the ship under Reg. 10 has been completed, no change shall be made to equipment without sanction of the administration. Ship's crew has modified cylinder oil piping for main engine and attached a 55 gallon drum to be utilized as an additional cylinder oil tank for different weight oil while in ECA using LSFO.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 November 2017
Resolved
After any survey of the ship under Reg. 10 has been completed, no change shall be made to equipment without sanction of administration. Ship's crew has modified ship's grey water piping and diverted directly to the sewage tank through an opening in the tank top. The sewage tank is currently diverted t the aft peak tank and is set up for automatic operation. Aft peak tank is not designated as a storage tank for sewage. Sewage tank vapors are open to the engine room causing a hazardous condition.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 20 November 2017
Resolved
Oil fuel tanks shall be part of the ship's structure. In general, the use of free-standing fuel tanks shall be avoided. Ships crew has modifies a 55 gallon drum containing kerosene with a spigot valve and has fabricated a semi permanent installation for its utilization as a cleaning agent.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 20 November 2017
Resolved
Arrangements for storage, distribution, and utilization of oil used in pressure lubricated systems shall be such as to ensure safety of the ship and persons onboard. There are eleven 55 gallon drum of cylinder oil stowed in the engine room (a category A machinery space). Chief engineer states these are needed when switching to low sulfur fuel oil when transiting an ECA per MARPOL. Ship is not outfitted with adequately permanent tank for this service.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 November 2017
Resolved
After any survey of the ship under Reg. 10 has been completed no change shall be made to equipment without the sanction of the administration. The piping for the oily water separator between the bilge pump discharge strainer and the separator has a leak. Additionally, there are two flexible hose soft patches on drain lines under the OWS.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 20 November 2017
Resolved
All engines in rescue boats shall be run weekly for a total period of not less than three minutes. During operational testing PSCO noted that rescue boat outboard engine was operated without cooling water. Chief officer stated that is how engine is tested for short periods and that cooling water is only used when engine is run for long periods of time. The Tohatsu outboard M18LD2 owner's manual states "Do not operate the engine without cooling water" in part 5- Engine operation - Starting.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 20 November 2017
Resolved
The company and ship shall comply with the requirements of the ISM code. During expanded SMS audit due to questions about class notifications and life saving maintenance procedures it was discovered that the listed arrangement for lifeboats (davit launched) do not match the current outfit (free-fall lifeboat). Recommend internal audit and corrective action to SMS manual. (See SMS AA-V-P-09.01.04 2009-12-01 Lifeboat Launching and Recovery). As incorrect arrangement is described, free-fall lifeboat and rescue boat outfit are not addressed.
Operations/Management › Drills/Instruction › Fire
Issued 20 November 2017
Resolved
Fire drills should be planned in such a way that due consideration is given to regular practice in various emergencies. Every company should develop, implement, and maintain a SMS which includes procedures to respond to emergency situations. During execution of the fire drill the fire team dressed out at the location of the announced fire, only one fire fighter arrived on scene to fight the fire which is contradictory to SMS AA-V-P-11.07.00, Paragraph 4.3. Additionally, the ships crew was not aware of the "Fire Control Checklist 1/2" which are required per paragraph 4.1.4.
Lifesaving › Lifebuoys › Serviceable
Issued 20 November 2017
Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. Ring lifebuoy at the rescue boat and in the vicinity of the starboard side accommodation ladder on aft bulkhead of house were both un-servicable.
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 October 2014
Resolved
S-Band radar was not operational.
Operations/Management › Pollution › Control of Garbage
Issued 18 October 2014
Resolved
2120 - Garbage - PSCO noted approx 7 cubic meters of plastics, glass bottles, and cans stowed in the forward bosun store and deck crane store No. 3 which are not designated as garbage storage areas. Provide garbage receipt prior to departure from the port of New Orleans - MARPOL Annex V/9
Documentation › Logs/Records › Garbage Recordkeeping
Issued 18 October 2014
Resolved
2120-Garbage-Vsl's Master has designated fwd bosun store & deck crane lockers No2 and No3 as "Additional Garbage Storage for Plastics" which is not an authorized storage area as per garbage mgnt plan. Provide clarification from Company w/ concurrence from Adm that these areas are authorized to store garbage & update vsl's garbage mgnt plan to reflect any Co./Adm approved changes-MARPOL Annex V/9
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 October 2014
Resolved
1750 - Oil Water Interface Detector - The Engineering Department did not know how to recall information from the Oil Content Meter memory. Provide corrective action plan from Company with concurrence from certificate issuing authority - MARPOL 73/78 Annex I/11.1
Construction/Loadline › Structures › Door
Issued 18 October 2014
Resolved
0199 - Other - PSCO observed an anti-piracy door the crew had fabricated, welded on the inside of the steering gear comp. adjacent to the second door upon entering the steering gear room. The anti-piracy door was not welded directly onto the steering gear door nor did it impede functionality. Provide clarification from the certificate issuing authority of the modification. - 74 SOLAS (Am. 09) I/11
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.