MARMARIS-M is a 2009 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in April 2026, along with 10 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 23 April 2026.

Built
2009
Last inspected
23 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9450791
3E3504
1052816
Flag
PANAMA
Maury page id
psix-1052816

Documentation record

Tonnage as PSIX records it11522 - Convention (Subpart B), Net Ton
43631 - Displacement, Ton
34340 - Dead Weight, Ton
23456 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

23 April 2026 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8352731
25 April 2024 PSC B · PSC A · COE-Administrative · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7899324
18 July 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6754611
14 July 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COE-Administrative
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6749104
13 February 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6354623
1 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6162421
3 November 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6034514
26 October 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6028567

Deficiency record · 10

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 April 2024 Resolved
The company and the ship shall complay with the requirements fot the internation Safety Management Code. For the purpose of this regulation the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external ISM audit report, satisfactory to the Coast Guard, must be submitted prior to clearance of this deficiency. 74SOLAS(2020CONS.)IX/3.1 ISM Code Part A/10.1 30ABC Detained
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 28 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 April 2024 Resolved
The following fire detection systems shall be kept in good order so as to ensure their required performance if a fire occurs. The following smoke detectors did not activate upon initial testing: two in the oil purifier space, two in the engine control room. One above the main engine, and one above the #1 main diesel generator (6 out of 31). 74SOLAS(2020CONS.)II-2/14.2.1.1.2 30ABC Detained
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 April 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 April 2024 Resolved
Oil fuel pipes shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire. Fuel oil supply pipes to the #1 and #2 main diesel generator's quick closing devices did not fully close when activated. 74SOLAS(2020CONS.) II-2/4.2.2.3.4 30ABC Deficiency rectified to the satisfaction of the CG
Action required: 30 - Ship detained
Resolved 25 April 2024
Resolution: Crew re-tested the quick closing fuel shut off valve to the satisfaction of the Coast Guard.
Lifesaving › Lifeboat › Propeller
Issued 3 November 2016 Resolved
0610: During operational test of the stern launch lifeboat, PSCO observed excessive shaft vibration and the propeller striking the rudder tunnel whenever throttled ahead. As the engine warmed up, the vibration reduced and the propeller was no longer striking the rudder tunnel. (From previous exam) 74 SOLAS 14 II-2/4.1.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2016
Resolved 3 November 2016
Resolution: Vessel was issued a temporary SOLAS CSSEC. Certificate and class paperwork in the documents tab.
Engineering › Generator (propulsion-electric) › Receptacle
Issued 26 October 2016 Resolved
0750: Means shall be provided to control leaks of flammable liquids. PSCO observed a steady drip of fuel oil coming from fuel oil return piping for #1 and #2 SSDG. 74 SOLAS 14 II-2/4.1.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2016
Resolution: Class submitted report stating fuel leaks have been repaired.
Lifesaving › Rescue Boat › Hull (inflated)
Issued 26 October 2016 Resolved
0615: Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. On the ships rescue boat, the PSCO observed that the inflatable port sponson was seperating from the transom. 74 SOLAS 14 III/20.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2016
Resolution: Class submitted a report stating the rescue boat has been replaced while the original is being repaired or replaced.
Lifesaving › Lifeboat › Propeller
Issued 26 October 2016 Resolved
0610: During operational test of the stern launch lifeboat, PSCO observed excessive shaft vibration and the propeller striking the rudder tunnel whenever throttled ahead. As the engine warmed up, the vibration reduced and the propeller was no longer striking the rudder tunnel. 74 SOLAS 14 II-2/4.1.1 16ac
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 28 October 2016
Resolution: Class report was received stating that class issued a condition for the issue to be addressed at its next port.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 October 2016 Resolved
1730: Exvept as specified in paragraph 3 of this regulation, any ship of 10,000 GT and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. During an operational test of the OWS, PSCO observed the discharge solenoid valve was never opened as designed. MARPOL 2011 ANNEX I/14.2 16ac
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 28 October 2016
Resolution: Received class report stating the valve assembly was replaced and tested and is in satisfactory working order.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 26 October 2016 Resolved
0720: While testing the emergency fire pump, PSCO observed inadequate water pressure coming from the hoses. After over an hour of troubleshooting, crew was able to perform a satisfactory test of the emergency fire pump. Crew members stated they had a low pressure because the anchor wash valve was left open. 74 SOLAS 14 II-2/14.2.1.2 10c
Action required: 705 - Other - as specified
Resolved 26 October 2016
Resolution: Crew was able to perform a satisfactory test of the emergency fire pump.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 October 2016 Resolved
9900: Vessel must conduct quarterly qualified individual notification exercises. While on board, the crew could not provide a current QI notification exercise. The captain contacted the QI for a satisfactory QI notification exercise. 33CFR 155.1060(a)(1) 10c
Action required: 705 - Other - as specified
Resolved 26 October 2016
Resolution: The captain contacted the QI for a satisfactory QI notification exercise.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.