MAURY USCG vessel records Sign in
← All vessels

GINGA LYNX

GINGA LYNX is a 2009 tank ship. The Coast Guard has recorded 23 inspections since 2010, most recently in November 2025, along with 1 deficiency and 14 operational controls, 2 with no removal date recorded.

Records from 2010 to 2025. Most recent: inspection, 19 November 2025.

Built
2009
Last inspected
19 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

9442550 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1053101
Flag
PANAMA
—
Maury page id
psix-1053101

Inspections, by type

…with no type recorded13
Years with a record 9 calendar years (2010–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7683 - Convention (Subpart B), Net Ton
16452 - Convention (Subpart B), Gross Ton
33552 - Displacement, Metric Ton
25900 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

19 November 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8268698
2 October 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7799310
8 March 2022 Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7406276
14 March 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6642252
7 May 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6408500
25 April 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6399102
13 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6391023
15 November 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6307681
27 October 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6296452
7 September 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6261943
2 July 2017 COC-CHEM & TVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6192773
23 June 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6184557
16 December 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6058825
15 July 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5941459
14 July 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5950985
1 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4331346
21 May 2012 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4316354
18 February 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3682021
14 February 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3679894
12 February 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3679384
9 February 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3677716
6 February 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3676002
2 February 2010 COC-TVE Renew · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3671334

Deficiency record · 1

Deck/Cargo › Vapor Control Systems › Inerting System
Issued 2 July 2017 Resolved
1199-Other (cargo)- Instrumentation shall be fitted for continuously indicating and permanently recording when IG is supplied. PSCO observed recording device inoperable. FSS Code 15.2.2.4.2 50a
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 7 September 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.

Ownership record