MAURY USCG vessel records Sign in
← All vessels

ST MAUD

ST MAUD is a tank ship. The Coast Guard has recorded 7 inspections since 2010, most recently in December 2011, along with 9 deficiencies and 2 operational controls.

Records from 2010 to 2011. Most recent: inspection, 23 December 2011.

Built
Not recorded
Last inspected
23 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9221803 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1053118
Flag
BELGIUM
—
Maury page id
psix-1053118

Inspections, by type

…with no type recorded1
Years with a record 2 calendar years (2010–2011)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3195 - Simplified, Net Ton
6519 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

23 December 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4213071
20 September 2011 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4148796
10 September 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4140837
6 October 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3864809
8 February 2010 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676934
4 February 2010 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3675296
2 February 2010 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3674185

Deficiency record · 9

Lifesaving › Lifeboat Equipment › Food Ration
Issued 20 September 2011 Resolved
Vessel found to have 8 food rations with a broken seal and 3 missing. Vessel shall have a total of 19 food rations onboard.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 21 September 2011
Resolution: Vessel purchased 11 food rations and showed proof of food rations through invoice and pictures.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 20 September 2011 Resolved
Smoke detection tested in steering and generator space. Indicators on bridge, engine control room and 2nd assistant engineer cabin activated but no audible signal sounded in machinery space.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 7 October 2011
Resolution: PSC verified class report stating siren was ordered and class will be witnessing instillation and operation of alarm.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 20 September 2011 Resolved
Exposed wiring found on the #2 boiler thermo coupler and 110 volt control switches to potable water.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 7 October 2011
Resolution: PSC went onboard vessel and verified exposed wiring is properly covered and no electrical hazards remain.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 20 September 2011 Resolved
Emergency stop labels on port and stbd found to be not legible.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 21 September 2011
Resolution: Vessel provided pictures of labeling of Port and Stbd manifold and PSC team verified on board vessel.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 20 September 2011 Resolved
Vessel vapor control system piping at manifold found with no labels.
Action required: 705 - Other - as specified
Due 27 September 2011
Resolved 21 September 2011
Resolution: Vessel provided pictures of markings on the Vapor lines piping manifold and PSC team verified markings on board vessel.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 20 September 2011 Resolved
Vessel is required to have on board documentation for the approval of this system issued by the USCG Marine Safety Center.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 September 2011
Resolution: Vessel provided class report with documentation of conformity with drawings of the system.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 February 2010 Resolved
Vessel is not equipped with 2 sets of portable gas calibration equipment calibrated to measure LEL. Prior to entering any tank, portable gas meters must be fully operational. IBC Code Chpt 13.2.1
Action required: 705 - Other - as specified
Due 9 February 2010
Resolved 5 April 2010
Resolution: Rcvd calibration and test report from vessel satisfying the requirements.
Documentation › Markings/Placards › Warning Signs
Issued 2 February 2010 Resolved
Vessel is not equipped with the legend "Tank Overfill Alarm" in black letters at least 50 mm (2 inches) high and on a white background. Vessel shall obtain this legend prior to cargo operations. 46CFR39.20-7 (d)(3)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2010
Resolution: MSUPA received pictures via email attesting to the correct placarding required by 46CFR39.20-7(d)(3).
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 2 February 2010 Resolved
Vessel is not equipped with operating Oil Discharge Monitoring Equipment (ODME). Vessel shall obtain documentation from Class attesting to the proper repair and operation of the ODME. MARPOL Annex 1, Reg 31
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 8 February 2010
Resolution: Vessel submitted a class report attesting to the proper operation of the Oil Discharge Monitoring Equipment.

Ownership record