MAURY USCG vessel records Sign in
← All vessels

KIRBY 11011B

KIRBY 11011B is a 2010 tank barge. The Coast Guard has recorded 17 inspections since 2010, most recently in May 2025, along with 2 deficiencies.

Records from 2010 to 2025. Most recent: inspection, 8 May 2025.

Built
2010
Last inspected
8 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1053392
Flag
UNITED STATES
—
Maury page id
psix-1053392

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2010–2025)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.0 ft
Registered tonnagegross 705 / net 705
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it705 - Simplified, Net Ton
705 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

8 May 2025 Internal Structural Exam · Administrative Inspection · COI Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8130948
15 May 2020 MTSA Verification · Hull Examination · COI Inspection · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6951386
3 April 2019 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6754012
1 June 2018 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6524587
22 June 2017 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6183508
20 March 2016 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5873078
14 October 2015 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5742494
28 April 2015 MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5106834
27 June 2014 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4901893
7 February 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4796095
16 January 2014 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4839197
21 March 2012 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4268502
2 February 2011 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3964704
3 December 2010 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3903250
8 August 2010 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3819452
28 April 2010 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3725353
29 March 2010 Cargo Tank Internal · Initial Construction-Excluding Oversight · Internal Structural Exam · MTSA Verification · Hull Examination · Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3704896

Deficiency record · 2

Construction/Loadline › Hull › Side Shell
Issued 8 August 2010 Resolved
As the result of an allision on 08AUG10, this vessel sustained a 11" x 1" gash in her side shell plating approximately 4' below the sheer strake in the No.2S wing void tank. The vessel is to make permanent repairs, by cropping and renewing the damage.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2010
Resolved 20 August 2010
Resolution: Completed sat air test of 14''6" X 7'' sideshell insert and 7'' X 2'' bulkhead insert IWO #2/#3 stbd wing voids.
Construction/Loadline › Hull › Bottom Plating
Issued 13 April 2010 Resolved
Make permanent repairs to starboard # 1 wing void in way of knuckle upset and port #2 wing void upset in hull bottom, as described in damage report.
Action required: 705 - Other - as specified
Due 13 May 2010
Resolved 28 April 2010
Resolution: Repairs completed and examined satisfactorily,

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.