SAN SALVADOR

SAN SALVADOR is a 2016 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in June 2026, along with 43 deficiencies — 1 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2016.

Records from 2016 to 2026. Most recent: inspection, 22 June 2026.

Built
2016
Last inspected
22 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI7917
1053834
Flag
UNITED STATES
Maury page id
psix-1053834

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2016–2026)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)70.7 ft × 24.5 ft × 12.5 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)70.7 ft × 24.5 ft × 12.5 ft
ITC tonnagegross 147 / net 44
BuilderMARITIME MUSEUM ASSOCIATION OF SAN DIEGO · SAN DIEGO, CA, UNITED STATES · built 2016
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
147 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 26

22 June 2026 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8405189
6 November 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8271220
8 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8130634
16 December 2024 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8048133
31 October 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8027875
24 October 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7813735
22 June 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7720790
6 October 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7573917
10 August 2021 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7282417
12 July 2021 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7254007
4 December 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7106280
19 November 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7098476
21 May 2020 Internal Structural Exam · Drydock Extension
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6957008
8 November 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6852128
15 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6834619
13 December 2018 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6597421
27 November 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6587385
10 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6536897
24 July 2018 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6489258
25 September 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6274693
7 September 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6261585
25 January 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6077317
28 December 2016 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6063183
27 October 2016 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6034238
15 August 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5974459
14 July 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6528586

Deficiency record · 43

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's fuel shutoff valve broke during testing. Fix valve and notify local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2026
Resolution: Received video of fuel cut-out valve handle fixed. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 May 2025 No resolution recorded
A pre-engineered fixed gas fire extinguishing system must be in compliance with § 181.420 and may only be installed in a normally unoccupied machinery space with a gross volume of not more than 57 cubic meters (2,000 cubic feet). Vessel has a fire boy servicing a space roughly 2700 cubic feet. Submit plans to MSC for a system in compliance with § 181.410 Fixed gas fire extinguishing systems. Vessel will be not allowed to sail if plans are not submitted to MSC with in 30 days.
Condition: Invalid
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 May 2025 Resolved
Discovered cracked plank in the STBD bow approximately 15 ft below the water line. submit repair proposal after paint has been removed and crack has been further inspected.
Action required: 705 - Other - as specified
Resolved 12 May 2025
Resolution: Aproved sealing of crack of 2in 1/4 in deep. Sealed crack, all sat. Will assess at next drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 22 November 2024 Resolved
In general, a rescue boat must be a small, lightweight boat with built-in buoyancy and capable of being readily launched and easily maneuvered. Vessel's rescue boat is not stored ready for rapid deployment. Propose a new launching system for the vessel's rescue boat for OCMI approval. Once approved, install the new launching system and demonstrate deployment of the rescue boat to attending USCG marine inspector. Vessel is restricted to a lakes, bays, and sounds route until rectified.
Action required: 705 - Other - as specified
Resolved 16 December 2024
Resolution: Vessel launches boat utilizing yard arm and rigging.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2023 Resolved
04 adult life jackets were found with inoperable lights. Complete an inventory and test the lights on all life jackets. Replace or repair any inoperable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 31 October 2023
Resolution: Received photos of new lights installed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 October 2023 Resolved
3 of 4 emergency lighting fixtures in the aft bunk room were found dim and not fully illuminated. Troubleshoot the 3 light fixtures and restore to full illumination.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 31 October 2023
Resolution: Received photos of new fixtures installed and working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 October 2022 Resolved
Each survival craft must be secured to the vessel by a painter with a float free link permanently attached to the vessel, stowed that when the vessel sinks the survival craft floats free. The vessels painter was tied to the deck and not to the weak link.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 October 2022 Resolved
Each EPIRB must be tested monthly and the test is required to be logged or documented otherwise. There were no EPIRB tests documented but the crew was able to document one EPIRB test on 05OCT2022 in the presence of the MI due to the crew stating the EPIRB was tested on that date.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 October 2022 Resolved
Fire Drills, Abandon Ship and Man Overboard drills and training shall be logged or otherwise documented including the date of the drill and training and the general description of the drill scenario. The only drill recorded since December of 2021 was one man overboard drill on 18SEP2022.
Action required: 10 - Deficiency Rectified
Due 6 October 2022
Resolved 6 October 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 October 2022 Resolved
The COI and stability letter must be posted in a conspicuous place on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2022
Resolved 22 June 2023
Resolution: Posted stability letter and COI
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 October 2022 Resolved
On a wooden vessel of at least 26 feet in length a visual AND audible alarm must be provided at the operating station to indicate a high water level in all watertight compartments. Need to provide audio alarm at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2022
Resolved 24 October 2023
Resolution: Visual and audible indicators were installed at the operating station, test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 October 2022 Resolved
Plans for the installation and use of monitoring devices to ensure the wakefulness of the watchmen were due to the OCMI 90 days after publication of the interim rule published December 27, 2021. Plans must be submitted to the OCMI. Vessel restricted from carrying overnight passengers until watch alarm and integrated smoke detection is operational.
Action required: 705 - Other - as specified
Resolved 24 October 2023
Resolution: Watch alarm and integrated smoke detection were installed, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2021 Resolved
Wire in galley space labeled "lighting jumper 1" found to have unprotected dead end. Wire should either be removed or capped.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 8 October 2021
Resolution: pics sent to MI-[name withheld] w/ wire capped; ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2021 Resolved
Hose on wet exhaust system found to be leaking. Hose clamp should be adjusted to prevent leaking.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 10 September 2021
Resolution: Hose clamp tightened - [name withheld]
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 10 August 2021 Resolved
LPG tanks found to be overdue for 5 year inspection. Tanks should be replaced or tested in accordance with manufacturers instruction.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 8 October 2021
Resolution: LPG tanks replaced; Pics sent to MI- [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 August 2021 Resolved
Engine room ventilation damper found to be inoperable. Provisions must be made for closing all supply duct cowls and discharge openings for a space protected by a fixed gas extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 30 September 2021
Resolution: Witnessed proper operation of E/R ventilation dampers - [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 August 2021 Resolved
Vent in Galley found to be missing external cover/ guard. Cover should be installed to prevent injury.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 8 October 2021
Resolution: Pics sent to MI; cover installed - [name withheld]
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 August 2021 Resolved
First Aid kit found to be missing ammonia inhalants. The appropriate amount of ammonia inhalants should be included within the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 28 October 2021
Resolution: Verified presence of all required First Aid Kit contents - [name withheld]
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 December 2020 Resolved
The secondary means of escape from the crew quarters is not appropriately sized for the rapid evacuation of all persons accommodated in that space. Prior to operating, you must submit a proposal for modifying the secondary means of escape from the crew quarters which includes adequate clearance for rapid escape by crewmembers. 46 CFR 177.500
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2021
Resolved 10 August 2021
Resolution: Proposal submitted on 10AUG2021...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 December 2020 Resolved
The pressure sensor on the pre-engineered fire extinguishing system (fireboy) was inoperable. Prior to operating, the system must be repaired to the satisfaction of the attending marine inspector. 46 CFR 181.400
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2021
Resolved 10 August 2021
Resolution: Tested on COI renewal exam...[name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 December 2020 Resolved
The hydrostatic release was removed from both inflatable liferafts and their painters were not secured to the vessel for automatic operation. Prior to operating, the liferafts must be fitted with properly rigged hydrostatic releases in a float-free, automatic arrangement. 46 CFR 180.13
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on renewal exam...[name withheld]
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 December 2020 Resolved
The EPIRB hydrostatic release was expired. Prior to operating, renew the EPIRB hydrostatic release. 46 CFR 180.64
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on renewal exam...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2020 Resolved
The audible alarm on the forepeak bilge high level alarm was inoperable. Repair to the satisfaction of the attending marine inspector. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on COI renewal...[name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 4 December 2020 Resolved
The vessel does not have an FCC Bridge-to-Bridge Radiotelephone Certificate. Provide a certificate within 30 days or prior to operating, whichever is later. 47 CFR 80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on COI renewal...[name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 December 2020 Resolved
The fresh water pump beneath the passenger bunkroom is wired with a wire splice completed with wire nuts outside an enclosure as required by 46 CFR 183.340(g). Rewire the pump using one of the authorized methods listed in 183.340(g) within an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on COI renewal...[name withheld]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 December 2020 Resolved
An electrical box within the galley is not mounted to the bulkhead. Securely mount the electrical box. 46 CFR 183.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on COI renewal...[name withheld]
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 4 December 2020 Resolved
There are no unexpired alcohol test strips on board. Provide current test strips within 30 days or prior to operating, whichever is later. 46 CFR 4.06-3(a)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on COI renewal...[name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 December 2020 Resolved
The tide and current tables on board are out of date. Provide 2021 versions of the publications within 30 days or prior to operating, whichever is later. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2021
Resolved 10 August 2021
Resolution: Verified on COI renewal exam...[name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2020 Resolved
VESSELS MUST UNDERGO AN ANNUAL INSPECTION WITHIN 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. COMPLETE THE REQUIRED ANNUAL INSPECTION PRIOR TO CARRYING PASSENGERS ONBOARD.
Action required: 705 - Other - as specified
Resolved 4 December 2020
Resolution: Completed annual exam on 04DEC2020...[name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 November 2019 Resolved
Provide vessel with an additional 04 distress signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 13 November 2019
Resolution: Received photo of invoice for new distress signals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2019 Resolved
Replace wasted grab line on forward life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 13 November 2019
Resolution: Received photos of replaced grab line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2019 Resolved
Permanently wire galley ventilation fan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 13 November 2019
Resolution: Galley fan was removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 November 2019 Resolved
Provide vessel with emergency instructions for; Rough Weather / Seas, Man Overboard, and Fire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 30 January 2020
Resolution: Received copy of emergency instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 November 2019 Resolved
Provide vessel with rescue boat for the recovery of a helpless person. Vessel does not meet the OCMI's determination that it is sufficiently maneuverable to recover a helpless person from the water.
Action required: 705 - Other - as specified
Due 8 May 2020
Resolved 30 January 2020
Resolution: Vessel procured rescue boat and trained crew on launching and recovery operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2019 Resolved
Remove burnt surge protectors from vessel.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Removed from vessel, educated operator.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 October 2019 Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side. Mark emergency escape hatch with proper marking on both sides.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Marked as directed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 October 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck to activate upon power loss. Install emergency lighting as directed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Light switches to remain in the "ON" position at all times.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2019 Resolved
Remove plastic trash cans from vessel.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 October 2019
Resolved 15 October 2019
Resolution: Removed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 November 2018
Resolution: Verified in VIVS
Fire Fighting › Fire Pumps › Pressure
Issued 7 September 2017 Resolved
Prove proper operation for fixed electrical fire pump @ 60 PSI to the attending marine inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2017
Resolution: The fire pump and motor was replaced and properly tested @70 PSI at the gauge.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 28 December 2016 Resolved
1. Make effective repairs to the portside drive shaft and reduction gear coupling. Prove proper operation to the attending Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 January 2017
Resolution: All repairs satisfactory. Deficiency cleared.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 15 August 2016 Resolved
Provide cause of remote prop control failure and repain IAW manufacturers instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2016
Resolved 18 August 2016
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 15 August 2016 Resolved
Prove proper operation of prop control
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2016

Casualty record · 1

14 July 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6528586
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.