ALASKAN is a 2010 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2010, most recently in March 2026, along with 46 deficiencies.

Records from 2010 to 2026. Most recent: inspection, 3 March 2026.

Built
2010
Last inspected
3 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ8452
1054115
Flag
UNITED STATES
368026160, 368462190
Maury page id
psix-1054115

Inspections, by type

Years with a record 14 calendar years (2010–2026)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)30.0 ft × 10.5 ft × 4.5 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2010
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton
9 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ8452MMSI 368462190 · active · voluntarily equipped · granted 17 March 2026, expires 17 March 2036
WDJ9449MMSI 368026160 · active · compulsorily equipped · granted 8 March 2018, expires 8 March 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

3 March 2026 COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8319010
7 January 2026 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8310021
4 September 2025 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8226900
18 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8094941
18 September 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8005229
22 May 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7691564
17 April 2023 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7679918
9 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7634814
5 August 2022 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7620701
25 July 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7516127
16 July 2021 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7257600
6 July 2021 Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7247575
7 October 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7073625
15 July 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7014114
9 April 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6937541
26 February 2020 Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6916509
3 February 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6901933
17 May 2019 Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6690099
6 April 2018 Internal Structural Exam · Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6386921
1 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6152439
23 May 2016 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5886634
22 April 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5862161
20 June 2014 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4894238
27 June 2012 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4357613
23 February 2010 Simplified Stability Test · Hull Examination · Plan Review "T" Boat · Construction Oversight · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3681148

Deficiency record · 46

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 September 2025 Resolved
FLAMMABLE VAPOR DETECTION SYSTEMS (E) A SENSOR MUST BE LOCATED ABOVE THE EXPECTED BILGE WATER LEVEL IN THE FOLLOWING LOCATIONS: THE LOWEST PART OF A SPACE CONTAINING A FUEL TANK WHEN SPERATE FROM MACHINERY SPACE. VAPOR DETECTED WAS HANGING AND NOT SECURELY MOUNTED 46 CFR 182.480
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2025
Resolution: RECTIFIED
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2025 Resolved
EACH RING LIFE BUOY MUST BE MARKED IN BLOCK CAPITAL LETTERS WITH THE VESSEL'S NAME. RING BUOY MISSING VESSELS NAME. 46 CFR 131.875
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 4 September 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 May 2023 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly. The EPIRB test shall be logged or otherwise documented. Abandon ship and man overboard drills and training shall be logged. The drill entry shall include the following information: date of the drill and training and general description of the drill scenario and training topics. Log entries for 2022 operating season only included 2 months worth of EPIRB testing. Drill entries for drills were not made IAW the regulations. Provide copy of logs from the months of May and June to the CG inspector. 46 CFR 185.728; 46 CFR 185.520(f)
Action required: 705 - Other - as specified
Resolved 5 June 2023
Resolution: drills logged.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 May 2023 Resolved
A vessel must carry up-to-date U.S. Coast Pilot. Copy provided was from 2021. Provide up-to-date publication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 5 June 2023
Resolution: Up to date pubs on board.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 May 2023 Resolved
An identification code, recognized by NOAA must be programmed in each EPIRB unit to establish a unique identification for each EPIRB station. NOAA registration sticker was missing. Place NOAA sticker on EPIRB. 47 CFR 80.1061(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 5 June 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2023 Resolved
A fire bucket must have an attached lanyard, placed so as to be easily available during an emergency. Lanyards were missing. Install lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 5 June 2023
Resolution: lanyards installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2023 Resolved
Each ring life buoy with a floating waterlight must have a lanyard 3-6' in length. Line was less than 3' at the time of inspection. Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name was missing at the time of inspection. 46 CFR 180.70(a)(2); 46 CFR 185.604(b)
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: Line was re-attached to measure more than 3' long. Vessel name stenciled on the RLB.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2023 Resolved
A vessel on a lakes, bays, and sounds route must carry three hand red flare distress signals and three hand orange smoke distress signals. Only 02 red flare distress signals were onboard at the time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: One additional red flare placed on the vessel.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 May 2023 Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve in located. Starboard fuel shutoff valve did not close completely when actuated from the emergency pull-station on deck.
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: Valve was adjusted and closed fully upon actuation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2023 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Combustible waste receptacles being used onboard the vessel. Remove combustible trash cans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 5 June 2023
Resolution: combustible cans removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 May 2023 Resolved
A vapor detector must be located above the expected bilge water level. Vapor detector was not mounted in the aft compartment. Properly mount.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 5 June 2023
Resolution: vapor detector mounted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 July 2022 Resolved
The COI must be posted under glass or other suitable transparent material such that all pages are visible in a conspicuous place. COI and stability letter were in a folder. Mount COI and Stability letter as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2023
Resolution: Received picture from vessel operator of COI posted.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 July 2021 Resolved
Vessels fixed fire system shall be inspected and functionality of ventilation shut down, remote manual pull station, alarms, and system integrity verified annually by a certified fire technician. Fire system was tagged for annual service however there was no proof of functional test of the system.46 CFR 176.810
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 21 July 2021
Resolution: Owner provided proof of service technician.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 16 July 2021 Resolved
Vessel is required to carry a First Aid Kit. Found expired item (aspirin) in the vessels first aid kit.46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 21 July 2021
Resolution: Owner replaced the expired aspirin in the vessels first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2021 Resolved
Vessels child life jackets shall be separated from the adult life jacket and marked quantity and location of storage. Found child life jackets stored with the adult life jackets.46 CFR 180.78
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 21 July 2021
Resolution: Owner separated and marked the child life jacket stowage location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2021 Resolved
Owner is required to have the crew of the vessel tested for alcohol within two hours following a serious marine incident. Vessel operates more than two hours away from a DOT approved drug and alcohol testing facility, therefore should have alcohol test strips onboard the vessel while operating.46 CFR 4.06-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 21 July 2021
Resolution: Owner purchased new un expired alcohol test strips and placed them onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 July 2021 Resolved
Vessel shall have up to date navigation charts onboard while operating. Vessels charts are out of date / not updated since 2018.46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 21 July 2021
Resolution: Owner purchased new 2021 navigation charts for vessels operating areas.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2021 Resolved
OCMI requires Carbon Monoxide tester in the passenger cabin due to the use of a diesel fired heating system in use. Found the carbon monoxide detector expired with dead batteries.46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 21 July 2021
Resolution: Owner replaced the CO detector with a brand new one - test sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 July 2021 Resolved
Vessel is required to have a means to close off ventalation to the fuel tank void space. Ventilation closing devices were missing / not onboard.46 CFR 182.460
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2021
Resolved 16 July 2021
Resolution: Owner placed raggs onboard in a designated area for the crew to use to close off the ventilation to the fuel tank void.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2021 Resolved
Vessels crew is required to have a pre employment drug test and be enrolled in the company's consortium. Newly hired deckhand was not pre employment tested or enrolled in the company's drug testing consortium.46 CFR 16.210
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 21 July 2021
Resolution: Owner provided a crew that was pre employment drug tested and properly enrolled in the company's random drug testing consortium.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 May 2018 Resolved
Mark lifebuoy with vessel's name in 2" block capital letters - 46 CFR 185.604 - 22 May 2018
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Lifebuoy marked.
Navigation › Piloting/Steering › Marine Charts
Issued 6 April 2018 Resolved
Provide updated navigational charts for operating area - 46 CFR 184.420 - 22 May 2018.
Action required: 705 - Other - as specified
Due 22 May 2018
Resolved 15 May 2018
Resolution: Operator provided new charts.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 1 June 2017 Resolved
Fire extinguisher in head was not inspected during Annual inspection of fire equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 2 June 2017
Resolution: SE Extinguishers attended and inspected extinguisher.
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2017 Resolved
Charts onboard were not corrected to LNM. Charts to be corrected or replaced with current charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 28 June 2017
Resolution: Verified presence of new charts onboard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 June 2017 Resolved
Current letter from Drug Consortium not onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 28 June 2017
Resolution: Received drug consortium enrollment letter from Master.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2016 Resolved
Install 3-5' of line with a corrosion resistant clip onto the vessels life ring buoy floating light.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 24 May 2016
Resolution: Owner installed a line w/corrosion resistant clip onto float light.
Engineering › Bilge Water Management System › Not Installed
Issued 23 May 2016 Resolved
Provide the required hand held portable bilge pump. Not onboard at time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2016
Resolved 23 May 2016
Resolution: Owner placed onboard a new portable hand bilge pump w/hose.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 23 May 2016 Resolved
Properly repair vessels vapor detection system in the fuel tank void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2016
Resolved 23 May 2016
Resolution: Owner replaced vapor detector sensor and system tested-SAT.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 20 June 2014 Resolved
Distress signals were not in a brightly colored, watertight container marked distress signals.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 3 July 2014
Resolution: Distress signal box purchased.
Engineering › Bilge Water Management System › Hose
Issued 20 June 2014 Resolved
Hand bilge pump hose is not of adequate length to allow water to be pumped from most bilge areas on the vessel.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 3 July 2014
Resolution: Longer hose purchased and attached to hand bilge pump.
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 June 2014 Resolved
Childrens Lifejacket stowage location is not marked and not readily apparent to passengers.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 3 July 2014
Resolution: Placard made and placed to indicate location and number of children''s lifejackets.
Personnel › Training › Fire Fighting Basic
Issued 27 June 2012 Resolved
Provide master and deck hand to conduct emergency drills in the presence of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 23 August 2012
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 June 2012 Resolved
Vsl reduced to 15 total persons allowed onboard due to missing one type one PFD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 16 July 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 June 2012 Resolved
Provide operating instructions and label the remote pull station for vsl's fixed fire system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2012
Resolved 23 August 2012
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 June 2012 Resolved
Complete an FCC safety radio inspection and have onboard a current FCC Safety Radio Certificate.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 January 2013
Resolved 22 January 2013
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 26 June 2012 Resolved
Vsl operator must have a FCC radio operators permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 16 July 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 June 2012 Resolved
Repair the vessel's anchor light. PRIOR TO OPERATING VSL AT NIGHT OR REDUCED VISIBILITY.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 16 July 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 June 2012 Resolved
Repair or replace the vessel's float light and install a proper sized float light line. PRIOR TO OPERATING AT NIGHT OR WITH REDUCED VISIBILITY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 16 July 2012
Fire Fighting › Fire Bucket › Quantity
Issued 26 June 2012 Resolved
Have onboard x3 fire buckets, labeled fire bucket, with a proper length of line attached to the same. Vsl currently only has x2 fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 16 July 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 26 June 2012 Resolved
Provide proof of annual servicing for vessels fixed gas fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2012
Resolved 2 August 2012
Lifesaving › Visual Distress Signals (General) › Storage
Issued 26 June 2012 Resolved
Provide a proper water proof container for vsl's visual distress signals. With proper markings on the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2012
Resolved 16 July 2012
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 February 2010 Resolved
Contact Sector Juneau AK for a New to Zone Inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2010
Resolved 12 April 2010
Resolution: USCG Sector Juneau completed New to Zone Inspection
Lifesaving › Lifebuoys › Not on Board
Issued 23 February 2010 Resolved
Provide life ring and install onboard. Complete prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2010
Resolved 12 April 2010
Resolution: USCG Sector Juneau verfied presence and proper installation of life ring on board.
Lifesaving › Hand Flares › Not on Board
Issued 23 February 2010 Resolved
Provide visual distress signals and place onboard. Complete prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2010
Resolved 12 April 2010
Resolution: USCG Sector Juneau verified presence of hand flares on board.
Communications › Radio Communications › EPIRB
Issued 23 February 2010 Resolved
Provide, install and properly register EPIRB. Complete prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2010
Resolved 12 April 2010
Resolution: USCG Sector Juneau Verified presence and proper operation of EPIRB
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 February 2010 Resolved
Provide proof of proper enrollment in a drug and alcohol testing program for all crew members. Complete prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2010
Resolved 7 June 2010
Resolution: Verified, sat

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.