Records from 2011 to 2026. Most recent: inspection, 22 April 2026.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Net Ton
20 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
22 April 2026
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8346995
23 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8313978
11 June 2025
COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8153445
27 June 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7943347
29 January 2024
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7858966
22 June 2023
Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7721441
19 May 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7453877
15 February 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7396917
8 June 2021
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7220561
11 June 2020
Internal Structural Exam · Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6973296
11 March 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6926237
6 February 2020
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6904149
27 June 2019
DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6766019
28 August 2018
Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6526827
20 March 2018
Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6375419
30 May 2017
Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293376
11 August 2016
Internal Structural Exam · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5981696
29 January 2016
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5817706
2 June 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4866270
22 May 2012
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4328551
18 December 2011
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4210580
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2026
Resolved
Battery covers need to be install on top of batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2026
Resolved
Life ring light is not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 June 2025
Resolved
AFT high water alarm needs to have both audible and visual alarms. Repair visual alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 26 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 June 2025
Resolved
Replace 10 person life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 26 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025
Resolved
Renew retro tape on life ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 26 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2023
Resolved
Aft bilge pump indicator light does not come on when high water alarm sounds. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 7 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 June 2020
Resolved
Paint bottom life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: The bottom of life float was repainted
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 June 2020
Resolved
Strobe for life float is broken. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: Strobe for life float has been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 June 2020
Resolved
Life ring strobe clip is frozen. Renew clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2020
Resolution: Life ring strobe clip was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 June 2019
Resolved
Portside life ring reflective material is wasted. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
Resolution: Reflective material was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 June 2019
Resolved
Several adult life jackets have wasted reflective material. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
Resolution: All reflective material was renewed
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 June 2019
Resolved
Aft bilge pump automatic light is extinguished. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
Resolution: New wiring was installed and tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 June 2019
Resolved
Place shims between life floats, to prevent sticking.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2019
Resolution: All life floats were shimmed and all sat.
Construction/Loadline › Hull › Bracket
Issued 29 January 2016
Resolved
Crop and re-new all supporting brackets for the dive platform.
Condition: Damaged By Earlier Event
Due 8 March 2016
Resolved 8 March 2016
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 22 May 2012
Resolved
Life jackets are hanging on a bar that must be removed before life jackets can be accessed. This is not a readily accessible stowage arrangement. Stow life jackets in a readily accessible location for all persons on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2012
Resolved 22 June 2012