Records from 2016 to 2026. Most recent: inspection, 26 March 2026.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCWS INC · CLERMONT, NJ, UNITED STATES · built 2010
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portNORTH MYRTLE BEACH, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
26 March 2026
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8333760
14 March 2025
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8096717
19 March 2024
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7881852
6 March 2024
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7874998
15 March 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7649949
15 March 2022
Internal Structural Exam · Hull Examination · Drydock Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7412285
11 May 2021
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7194376
22 June 2020
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6983989
26 May 2020
Hull Examination · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6960953
22 April 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6667341
16 April 2018
Annual Inspection · Hull Examination · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6392554
15 March 2017
COI Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6103631
19 April 2016
DAPI Audit · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5861931
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 June 2022
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a).
Vessel missing portable hand pump.
46 CFR 182.520(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: New bilge handpump put into service.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 June 2022
Resolved
otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and
General description of the drill scenario and training topics.
Vessel had no recorded fire drills.
46 CFR 185.524(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: New log book purchased and most recent fire drill recorded.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 June 2022
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics.
Vessel had no recorded man overboard drills.
46 CFR 185.520(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: New log book purchased and most recent MOB drill recorded.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 June 2022
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
Vessel had no monthly EPIRB tests recorded.
46 CFR 185.728
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: New log book purchased and most recent EPIRB drills recorded.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 June 2022
Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Except on a vessel limited to daytime operations, the compass must be illuminated.
Vessel missing illuminated magnetic compass.
46 CFR 184.402
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: Magnetic compass installed at operating station.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 June 2022
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Vessel missing Emergency Broadcast placard.
46 CFR 184.506
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 24 June 2022
Resolution: New placard installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 May 2021
Resolved
Show proper operation of DSC for VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 June 2021
Resolution: DSC was installed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 May 2021
Resolved
Show proper operation of automatic switch for engineroom bilge pump.
Action required: 705 - Other - as specified
Resolved 29 June 2021
Resolution: A new switch was placed in service and tested.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 May 2021
Resolved
Replace battery for EPIRB utilizing a qualified third party.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: A new EPIRB was placed in service.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 May 2021
Resolved
Replace HRU for EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: A new HRU was placed in service.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 June 2020
Resolved
Place in service lens cover for all-around light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 23 June 2020
Resolution: A new lens cover was placed in service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020
Resolved
Replace 5:BC with 10:BC portable fire extinguisher.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 23 June 2020
Resolution: A new 10: B/C was placed in service.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 June 2020
Resolved
Show proper operation of engine compartment high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2020
Resolution: High water alarm was replaced and tested.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 22 June 2020
Resolved
Show proper operation of console alarm for fireboy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2020
Resolution: A new alarm for the Fireboy was placed in service and tested.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 April 2019
Resolved
Show proof of DSC operation of VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 July 2019
Resolution: Vessel had DSC set up on radio.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 April 2019
Resolved
Show proof of original FCC SSL.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 July 2019
Resolution: Original FCC SSL was placed on the vessel.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 19 April 2016
Resolved
Stern light inoperable.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 26 May 2020
Documentation › Certificates/Documents › FCC SSL
Issued 19 April 2016
Resolved
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 26 May 2020
Construction/Loadline › Hull › Bracket
Issued 19 April 2016
Resolved
Stern swim platform bracket cracked at the weld IVO attachment to hull.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 26 May 2020
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 April 2016
Resolved
Reflective tape missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 26 May 2020