NIKOLAOS A is a 2009 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in October 2021, along with 11 deficiencies and 3 operational controls.
Records from 2016 to 2021. Most recent: inspection, 10 October 2021.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it67802 - Displacement, Metric Ton 58133 - Dead Weight, Metric Ton 19458 - Convention (Subpart B), Net Ton 32287 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
10 October 2021PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7325638
2 January 2020ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6879139
6 January 2019Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6597971
3 June 2018ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6432755
16 February 2017PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6085904
16 February 2017Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6089353
14 August 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5972329
14 August 2016COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5972357
9 August 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5967714
25 January 2016Administrative Inspection · Deficiency Check
MACHINERY SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SEVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. INCINERATOR REFRACTORY OBSERVED IN SEVERELY WASTED CONDITION. SOLAS 74(2014 CONS.) CHAP 1/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 September 2018
Resolved 6 January 2019
Resolution: Received, reviewed and accepted class report from Korean Register of Shipping stating the deficiency was rectified. The wasted refractory of the incinerator was repaired and in good order and functional test was conducted.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 3 June 2018Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT, AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. THE EXTERIOR GRAB LINE ON THE STERN LAUNCH LIFE BOAT IS MISSING.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 September 2018
Resolved 6 January 2019
Resolution: Received, reviewed and accepted class report from Korean Register of Shipping stating the deficiency was rectified. Missing exterior grab line was installed.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 3 June 2018Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT, AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. VALVE WAS DISCOVERED INSTALLED IN OPENING FOR LUBE OIL SETTLING TANK.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 September 2018
Resolved 6 January 2019
Resolution: Received, reviewed and accepted class report from Korean Register of Shipping stating the deficiency was rectified. The valve in the the opening for the L.O. settling tank was removed.
Documentation › Logs/Records › Oil Record Book
Issued 3 June 2018Resolved
THE OIL RECORD BOOK PART 1 SHALL BE COMPLETED ON EACH OCCASION, ON A TANK TO TANK BASIS IF APPRORIATE, WHENEVER ANY OF THE FOLLOWING MACHINERY SPACE OPERATIONS TAKES PLACE IN THE SHIP. APPROPRIATE OIL RECORD BOOK ENTRIES NOT TRUE.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 June 2018
Resolved 3 June 2018
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 3 June 2018Resolved
CONDITION OF SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH PROVISIONS PRESENT REGULATIONS TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. Unapproved insulation installed in overhead of emergency generator room.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 June 2018
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 16 February 2017Resolved
1410-Propulsion Main Engine-The condition of the ship and its equipment shall be maintained to conform with provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO received report of a propulsion irregularity while U/W at MM 90 LMR. SOLAS (2014) II-1/11(a) 60a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 22 February 2017
Resolution: Class report recieved. Class verified replacement of siezed MDE fuel injectors to correct propulsion irregularity.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 16 February 2017Resolved
0611-Lifeboat Inventory-All life saving appliances and arrangements shall comply with the applicable requirements of the code. A food ration totaling not less than 10,000 KJ for each person the lifeboat is permitted to accomodate; these rations shall be kept in airtight packaging. PSCO observed three of the 25 10,000 KJ food ration packages were not airtight. SOLAS (2014)III/34&LSA CODE 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2017
Resolved 22 February 2017
Resolution: Received, reviewed and accepted documentation from owners stating the food rations were purchased and delivered to replace deficient rations.
2199-Other (MARPOL operational def.)-Company should ensure that procedures are in place to promptly remove obsolete documents. PSCO observed SOPEP had an outdated and innacurate competent authority contact list dated 23DEC2011. SOLAS (2014) IX/3.1 & ISM CODE A/11.2.3 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2017
Resolved 22 February 2017
Resolution: Received, reviewed and accepted class report stating the deficiency was rectified by providing SMS Document Control refresher training and by removing outdated and inaccurate SOPEP contact information.
9900-Other(not clearly hazardous)-Vessel is required to test bunker lines to a static liquid pressure at least 1 1/2 times the MAWP. PSCO observed record of last hydrostatic pressure test of bunker lines at 3.2 bar on 20SEP2016, but no evidence of MAWP was available to confirm sufficient pressure test. 33CFR156.170(c)(4) a
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Due 16 February 2017
Resolved 22 February 2017
Resolution: Received, reviewed and accepted proper documentation from ship operators that stating the deficiency was rectified by ensuring plan and procedures in place to properly test hystrostatic bunker lines to 1.5 MAWP.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 January 2016Resolved
1430 - Generator Cooling - Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Freshwater cooling system on #3 generator has a leak. 74 SOLAS (CONS ED 2004) II-1/26.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 25 January 2016
Resolution: SEC HOU-GAL PSC received a class report from NKK satisfying the requirement.
0599 - Occupational Safety - Steering gear compartments shall include gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. Steering gear room did not have a slip resistant deck. 74 SOLAS (cons ed 2004) II-1/ 29.13.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2016
Resolution: SEC HOU-GAL PSC received a class report from NKK satisfying the requirement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.