← All vessels
NILUFER SULTAN
NILUFER SULTAN is a 2008 tank ship. The Coast Guard has recorded 16 inspections since 2010, most recently in April 2021, along with 16 deficiencies and 2 operational controls.
Records from 2010 to 2021. Most recent: inspection, 19 April 2021.
- Built
- 2008
- Last inspected
- 19 April 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9410131 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7ZG3
1054589
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1054589
Inspections, by type
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6766 - Convention (Subpart B), Net Ton
19999 - Dead Weight, Ton
26505 - Displacement, Ton
12619 - Convention (Subpart B), Gross Ton
19999 - Dead Weight, Ton
26505 - Displacement, Ton
12619 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
19 April 2021
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7171163
18 April 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7177635
9 March 2021
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7152735
11 June 2019
ISPS III Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6704778
23 May 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6691625
6 May 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6677265
11 December 2016
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6056151
8 October 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6018819
18 September 2016
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6005914
2 July 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5926355
24 June 2016
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5917698
24 October 2014
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5011278
15 October 2014
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5005378
15 October 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5006831
14 October 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5005158
8 March 2010
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3692029
Deficiency record · 16
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 19 April 2021
Resolved
The condition of the ship and its equip1nent shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel has fuel migrating entering the ballast pump room and coffer dam below causing a hazardous condition in these spaces. 17 a,c
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 19 April 2021
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with the following provisions 2.2. l. PSCO observed active fuel, lube oil and water-jacket leaks on Main Engine, Generators and Scavenge Tank.17a.c
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 19 April 2021
Resolved
Each item of remote operating or indicating equipment, such as remotely operated valve, tank level alarm, or emergency shutdown device, must perform its intended function. PSCO could not test emergency shutdown of Cargo Pumps due to unknown cause. Prior to cargo discharge, CGMI must verify
proper operation of cargo pump emergency shutdowns.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 June 2019
Resolved
1430 - The machinery fittings shall be of a design and construction adequate for the service for which they are intended. The seal on the #1 Generator was found excessively leaking. - SOLAS II-I, Reg 26
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 11 June 2019
Resolved
9900 - Tankship liquid overfill protection. The "High" and "Overfill"" required by paragraph (a). The legends for the "High" and "Overfill" alarms need to be labeled in black letters at least 2" inches high on a white background.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 6 May 2019
Resolved
11124- An embarkation ladder complying with 6.1.6 of the Code shall be provided at each embarkation station. The forward embarkation ladder has cracked steps and frayed lines. SOLAS(2014)III/11.7
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2019
Resolved
02108 - Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault special precautions against such risk shall be taken. Multiple cable boxes in the cargo area of the deck are wasted & unable to be sealed. SOLAS (2004)II-1/45.5.4
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 May 2019
Resolved
02108 - Cables & wiring shall be supported in such a manner to avoid chafing. A wire going into a junction box by C.T.5(P) was chafed to the wiring. 74SOLAS(2004)II-1/45.5.5
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 May 2019
Resolved
07126 - Means shall be provided to control leaks of flammable liquids. The main engine and all three generators were covered with oil and had oil pooled beneath them. There is also multiple laggings covered with oil and oil covering the purifier room. SOLAS (2004)II-2/4.1.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo density declaration
Issued 6 May 2019
Resolved
06199 - Provisions shall be made to prevent liquid rising in the venting system by high level alarms. The high level alarm on cargo tanks #6(P) and #6(S) are inoperable. SOLAS(2004)II-2/11.6.3.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 May 2019
Resolved
06199 - Cargo containment system must have a second cargo overflow alarm. Overflow alarms on cargo tanks 9(S) and slop (P) and 7(P) are inoperable. 46CFR153.408(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 May 2019
Resolved
11199 - Disposable hydrostatic release units shall be marked with a means of determining the date of expiry. The hydrostatic release units on the port and starboard life rafts were not marked with expiration dates. SOLAS(2014)III/13.4.2; LSA 4.1.6.3.8
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 October 2014
Resolved
1745- 15 PPM alarm arrangements- Oil filtering equip shall be designed & approved by the Admin. In the event the 15pprm bilge alarm is replaced, means should be provided to ensure the data recorded remains available on board for 18 months. The oil content meter was replaced Sept 17, 2014. No data from the previous oil content meter is available. MARPOL Annex I Reg 14.7 MEPC 170(49) 4.2.9 50bc
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 October 2014
Resolved
0950- Electric equip in gen- Design, construction, equip, and operation of ships carrying NLS in bulk in Chap 17 of the IBC. Electrical equip shall conform acceptable to the Admin. Straps on cargo pump motors 1 & 5 stbd, 8 port are separated. Conduit to the cable boxes on tank 8 stbd and 10 port as well as conduit to pump on 3 stbd is fractured. MARPOL Annex II Reg 11.1.1 IBC Code 10.1.4 40ac
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 15 October 2014
Resolved
1099- Other (alarm-signals) Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm and tank overfill alarm. Both audible and visual alarms on tank 8 stbd are inoperable. 46 CFR 39.20-7(a) 40ac *must be rectified prior to loading in U.S. ports.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 March 2010
Resolved
During the course of the Engine room exam, it was discovered that the incinerator for oil residues did not operate. After more than one hour, Chief Engineer was unable to show proper operation to Port State Control Officer. Incinerator needs to be repair repair to the satisfaction of the certificate issuing authority.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.