MAURY USCG vessel records
← All vessels

HERBERT C BONNER

Built
1970
Last inspected
30 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH6669
105460
Flag
UNITED STATES
Maury page id
psix-105460

Documentation record

Registered dimensions (L × B × D)113.6 ft × 34.0 ft × 8.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)113.6 ft × 34.0 ft × 8.0 ft
ITC tonnagegross 191 / net 66
BuilderNEW BERN SHIPYARD INC · NEW BERN, NC, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBRISTOL, RI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
191 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
66 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 47 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

30 June 2026 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8420361
16 September 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8235578
10 June 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8168618
9 April 2024 COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7875005
26 January 2024 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7837973
27 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7703887
18 July 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7488577
19 January 2022 Examination of Repairs · Plan Review "T" Boat · Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7377829
7 December 2021 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7364058
6 December 2021 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7422744
22 June 2021 Annual Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7212492
22 February 2021 Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7139873
31 July 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7024683
9 July 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6983630
18 February 2020 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6894903
11 April 2019 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6657016
28 March 2019 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6641868
14 February 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6625922
15 October 2018 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6570186
25 September 2018 Internal Structural Exam · Drydock Extension
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6548436
27 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6524234
9 March 2018 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6385326
6 October 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6272580
29 June 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6184565
25 May 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6155409
25 May 2017 Deficiency Check · Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6155465
10 November 2016 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6034134
30 September 2016 Drydock Extension
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6012726
27 June 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5921345
16 June 2016 Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5909366

Deficiency record · 47

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2025 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Bilge piping in the forepeak void has a hole impacting the removal of water in the space. Crop and renew piping and test to satisfaction of CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 7 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2025 Resolved
A vessel of more than 65' in length must carry a minimum of 3 life buoys of not less than 24" in diameter. One life buoy on vessel is not serviceable. Replace life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 7 July 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2024 Resolved
Properly wire searchlights on top of wheelhouse with marine grade cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2024
Resolved 17 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 April 2024 Resolved
Secure jacket water coolant leaks on the starboard engine and starboard aft generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2024
Resolved 22 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Need several placards for each different type of children's and adult lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2024
Resolved 17 April 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 9 April 2024 Resolved
Alcohol swabs for marine casualty testing has expired. Replace with unexpired alcohol swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2024
Resolved 17 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 June 2023 Resolved
Watertight door in the aft bulkhead of engine space has improper gasket. Replace with proper gasket to ensure watertightness.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 27 July 2023
Resolution: New gasket installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2023 Resolved
On a vessel of more than 65' in length, the minimum capacity of the fire pump must be 50 gallons/minute at a pressure not less than 60 psi at the pump outlet. The pump outlet must be fitted with a pressure gauge. The pressure gauge on board is inoperable. Replace/repair pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 27 July 2023
Resolution: Fire pump gauge replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2023 Resolved
Stbd fire hydrant has a leak at the valve. Replace/repair packing in fire hydrant.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 27 July 2023
Resolution: Packing repaired
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 July 2022 Resolved
The rules concerning lights shall be complied with from sunset to sunrise. Secondary stern light is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 31 July 2022
Resolution: Stern light operable
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 July 2022 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use. Compass deviation card has not been updated since 2001.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2022
Resolution: Compass deviation card updated
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2022 Resolved
Control must be provided for the engine speed, direction of shaft rotation, and engine shutdown. Provide propulsion control drawing, limited QFA and test procedures to the CG to demonstrate compliance with 46 CFR 184.620.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 6 June 2022
Resolution: Received [name withheld]: E2-2201859 dated June 3, 2022. All sat.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 21 March 2022 Resolved
Vessel must have up to date stability details on an issued stability letter. Resubmit weight change calculations to MSC to account for Main Engine Foundation modifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 2 June 2022
Resolution: MSC LTR Serial: H1-2201860 dated May 31, 2022. All sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 June 2021 Resolved
The discharge end of fuel tank vent pipes must be fitted with flame screens of at least 30X30 mesh. Stbd flame screen has a hole in it. Vehicles within 6 feet and carriage of any hazardous cargo is prohibited until repairs are made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2021
Resolved 23 June 2021
Resolution: See Activity Number 7212492
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021 Resolved
Remove exposed wires and replace globe at the port aft light.
Action required: 705 - Other - as specified
Due 29 June 2021
Resolved 29 June 2021
Resolution: See Activity Number 7212492
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2021 Resolved
Lower deck fire station valve leaking. Repack or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 29 June 2021
Resolution: See Activity Number 7212492
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021 Resolved
Wire nuts shall not be used except in an enclosure. Place all spliced lines in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 20 July 2021
Resolution: See Activity Number 7212492
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021 Resolved
Remove unused wiring for forward deck lights and seal deck connection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 20 July 2021
Resolution: See Activity Number 7212492
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 June 2021 Resolved
Each watertight door must be capable of remaining watertight. Make both doors watertight with an approved gasket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 20 July 2021
Resolution: See Activity Number 7212492
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 June 2021 Resolved
Placards containing instructions for donning and use of the life jackets must be posted in conspicuous places. Obtain placard for all types of life jackets onboard the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 20 July 2021
Resolution: See Activity Number 7212492
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2021 Resolved
Repair ventilation shutdown on the main deck, exposed wires could cause injury if the glass is broken.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 20 July 2021
Resolution: See Activity Number 7212492
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 July 2020 Resolved
Stbd side navigation light inoperable. Vessel was equipped with a backup stbd light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 9 July 2020
Resolution: Replaced bulb.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 9 July 2020 Resolved
Clean excessive oil in e/r bilges. Clean/remove oiled pads.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 6 August 2020
Resolution: Engine room properly cleaned of excessive oil.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2020 Resolved
Wing nuts on battery terminals need to be replaced with permanent type connectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 31 July 2020
Resolution: Battery terminal properly wired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2020 Resolved
No rubber mats in front of switchboards in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 9 July 2020
Resolution: Provided mats in front of switchboards.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 July 2020 Resolved
Tighten shaft seal leak on #2 main engine. Shaft seal found with excessive leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 9 July 2020
Resolution: Tightened shaft packing. No more leak.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 July 2020 Resolved
Replace watertight gaskets in both engine room doors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 31 July 2020
Resolution: Replaced watertight gaskets
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 February 2020 Resolved
Hull corrosion found below the air compressor space in the engine room. Crop and renew subject hull plate.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 March 2020
Resolution: Plate cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 February 2020 Resolved
Brackets for the steering gear hydraulic lines in space aft of the engine room were found broken. Replace brackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 March 2020
Resolution: Brackets were replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 February 2020 Resolved
Remove deck plating in the engine room and make engine room available for inspection.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 5 March 2020
Resolution: Plate replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 February 2020 Resolved
Standing water in void spaces. Remove standing water in all voids and make bilge strainers available for inspection.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 5 March 2020
Resolution: After close-up inspection, no additional requirement needed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 March 2019 Resolved
Complete fire drill to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2019
Resolved 11 April 2019
Resolution: completed Drill
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 28 March 2019 Resolved
Complete MOB drill to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 11 April 2019
Resolution: Completed Drill
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 March 2019 Resolved
Properly mount fire extinguisher in pax accommodation space on second deck.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 11 April 2019
Resolution: Fire Ext. Mounted
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 February 2019 Resolved
Complete annual inspection prior to carrying passengers. Vessel is overdue for an annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 11 April 2019
Resolution: Inspection Complete
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: No Call Sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 14 September 2018
Resolution: Updated information is installed on AIS unit assigned to vessel.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 March 2018 Resolved
Found pitting IWO tank corner adjacent to shaft packing gland, port and stbd tanks. Repair to original condition.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2018
Resolved 22 March 2018
Resolution: Fuel tank repairs completed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 October 2017 Resolved
Retro reflective tape was unservicable. Worn and/or missing on all lifebouys. Renew reflective tape in the appropriate locations on the lifebouys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2017
Resolved 28 November 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 October 2017 Resolved
Lifeline was improperly installed on fwd stbd lifebouy. Properly install lifeline on bouy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2017
Resolved 28 November 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 29 June 2017 Resolved
Demonstrate Lat and Long on VHF radio.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 28 July 2017
Navigation › Piloting/Steering › Marine Charts
Issued 29 June 2017 Resolved
Provide updated chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 28 July 2017
Engineering › Lubricating Oil Service System › Gauge
Issued 29 June 2017 Resolved
Demonstrate proper operation of lube oil pressure gauge for the port main engine in the pilothouse.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 28 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 June 2017 Resolved
Asprin was expired. Provide new aspirn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 28 July 2017
Communications › Audible Communications › Bell
Issued 29 June 2017 Resolved
Provide 12" bell.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 28 July 2017
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 25 May 2017 Resolved
Obtain approved plans from MSC for the propulsion controls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 28 July 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 April 2017 Resolved
Conduct an annual COI inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2017
Resolved 29 June 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 April 2017 Resolved
Complete credit drydock and internal structural exam prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2017
Resolved 25 May 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.