Records from 2016 to 2026. Most recent: inspection, 29 January 2026.
Inspection history · 13
29 January 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8288556
19 December 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8049157
14 March 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7853842
8 February 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7853443
30 January 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8050857
23 February 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7619466
24 January 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7384671
26 January 2021
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7130748
7 January 2020
DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6884515
18 March 2019
Annual Inspection · Administrative Inspection · Deficiency Check · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6630731
18 January 2018
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6339520
26 April 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6121977
21 April 2016
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6057558
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 February 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the vessel must be equipped with an adult size lifejacket for each person authorized.
Vessel had 7 unusable lifejackets due to wear and sun exposure.
46 CFR 176.808(e)
Action required: 10 - Deficiency Rectified
Due 8 February 2024
Resolved 8 February 2024
Resolution: Owner replaced with 7 new lifejackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2024
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections. Inspector observed all extinguishers not serviced within 12 month period.
46CFR810(b)(1)(iv)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2025
Resolved 30 January 2025
Resolution: Vessel rep emailed photos of fire extinguishers with new service dates on service tag.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2024
Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25. Inspector observed mounting bracket for fuel shut off valve was broken off and no longer mounted properly.
46CFR182.458(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 4 March 2025
Resolution: Provided photo to verify fuel shut off valve mounted properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 February 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines.
Vessel did not have a fuel shut-off valve installed at the time of inspection.
Install fuel shut-off valve.
46 CFR 182.455(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2023
Resolved 23 February 2023
Resolution: Photo evidence submitted of installed fuel shut-off valve.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 March 2019
Resolved
Replace expired eye wash in first aid kit. 46CFR184.710
Action required: 705 - Other - as specified
Due 18 March 2019
Resolved 20 March 2019
Resolution: Verified new eye wash was placed on board in the first aid kit.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 January 2018
Resolved
Install A-II fire extinguisher iaw 46CFR181.500.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: Vessel provided A-II extinguisher onboard.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 January 2018
Resolved
Label PFD storage with number and adult/child iaw 46CFR185.604(f).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2018
Resolved 18 January 2018
Resolution: Vessel installed PFD labeling at storage
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 January 2018
Resolved
Install PFD instruction placard iaw 46CFR185.516(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2018
Resolved 2 February 2018
Resolution: PFD instruction placard installed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 January 2018
Resolved
Install fuel shut-off label iaw 46CFR185.608.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 25 January 2018
Resolution: Fuel shut-off label installed.
Engineering › Fuel Oil Service System › Piping
Issued 26 April 2017
Resolved
Replace flexible fuel hose with one meeting the requirements of 46CFR 182.720(e)(3)(v)
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 26 April 2017
Resolution: Fuel hose was replaced with correct type.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 April 2017
Resolved
Install cover on battery box. 46CFR183.350
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 26 April 2017
Resolution: A cover was strapped to the top of the battery box.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 April 2017
Resolved
Affix Type II retro reflective tape on ring life buoy. 46CFR185.604(h)(i)
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 26 April 2017
Resolution: Retro tape was affixed to both sides of the ring life buoy.