MAURY USCG vessel records
← All vessels

TANZANITE

TANZANITE is a 2010 freight ship. The Coast Guard has recorded 18 inspections since 2017, most recently in February 2026, along with 5 deficiencies and 5 operational controls.

Records from 2017 to 2026. Most recent: inspection, 25 February 2026.

Built
2010
Last inspected
25 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9456147
1054974
Flag
LIBERIA
Maury page id
psix-1054974

Documentation record

Tonnage as PSIX records it67681 - Displacement, Metric Ton
56843 - Dead Weight, Metric Ton
19231 - Convention (Subpart B), Net Ton
32987 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ERVIN S. COOPER Towing Vessel · MISLE 74159 · 19 August 2017 · activity 6247576

Inspection history · 18

25 February 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8316798
17 February 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8311393
23 May 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8140284
19 May 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8139068
19 May 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8139523
18 July 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7745456
1 November 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7587810
7 July 2021 Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7248762
7 July 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7250484
1 July 2021 Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7230368
18 January 2018 COE-Administrative · Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6339576
17 September 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6268244
17 September 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6268471
29 August 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6254930
19 August 2017 Deficiency Check · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6245343
19 August 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6245434
19 August 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6247576
26 July 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6221783

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 May 2025 Resolved
The fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Fire detection. PSCO observed a hole in cargo hold no. 2 CO2 line. Must be corrected prior to vessel carrying cargos requiring smoke extraction. SOLAS II-2/14.2.1.1.2 to the satisfaction of RO/ Coast Guard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 May 2025
Resolution: SEC NOLA received class report attesting to the rectification of this deficiency. Class report attached in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2022 Resolved
The machinery, boilers and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. It was reported there was an operational irregularity in main diesel engine. II-1/26, 10C.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 2 November 2022
Resolved 2 November 2022
Resolution: Received, reviewed, and accepted class report from NKK attesting to the operational readiness of the main diesel engine.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons onboard. PSCO received phone call from bar pilots that the vessel suffered loss of steering on #1 steering pum while departing the Port of Mobile. 74 SOLAS (2014) 1/11.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2021
Resolution: Received Kongsberg Service Report, NE1023214, dated 09JUL21, and Class NK report attesting to pressure adjustments to the steering hydraulic system balancing valves.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 19 August 2017 Resolved
1410-Storage, distribution, and utilization of oil fuel shall be such to ensure safety of the ship and persons on board. Vessel's main engine No. 2 fuel pump suction valve failed, resulting in a reduction of main engine's rpm's and subsequent allision. SOLAS (14) II-2/4.2.2 60ac
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 19 August 2017
Resolution: Vessel replaced No.2 fuel pump suction valve & main engine was tested to Class Society & Coast Guard's satisfaction.
Construction/Loadline › Hull › Side Shell
Issued 19 August 2017 Resolved
1299-Other(Load Lines)-A ship which is designed, constructed, & maintained in compliance with the appropriate requirements of an organization including a class society, may be considered to provide an acceptable level of strength. Vessel’s bow sustained an approximate 70’ x 10’ opening approximately 7’ above the waterline. ICLL Annex I/1 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2021

Ownership record