MAURY USCG vessel records
← All vessels

BLACK ROSE

Built
2010
Last inspected
18 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 18 May 2026
Operational controls None recorded without a removal date
Years with a record 15 calendar years (2010–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1055139
Flag
UNITED STATES
Maury page id
psix-1055139

Documentation record

Registered dimensions (L × B × D)33.0 ft × 14.1 ft × 7.3 ft
Registered tonnagegross 28 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSENESCO MARINE · NORTH KINGSTOWN, RI, UNITED STATES · built 2010
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEWPORT, RI
Endorsements, as the file codes themreg
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Net Ton
28 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

18 May 2026 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8375672
19 May 2025 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8110125
11 April 2025 Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8096182
16 May 2024 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7898289
28 April 2023 Periodic Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7668728
9 June 2022 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7457535
29 April 2021 Annual Inspection · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7176629
27 April 2020 MTSA Verification · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6944434
16 April 2020 Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6939989
6 May 2019 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6670387
8 May 2018 Annual Inspection · MTSA Verification · DAPI Audit · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6393960
9 May 2017 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6128746
2 May 2016 Deficiency Check · DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5847818
26 March 2015 COI Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5091156
12 May 2014 Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4856677
11 May 2012 Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4308286
19 May 2010 Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3742061
12 March 2010 Initial Construction-Excluding Oversight · MTSA Verification · Initial Certification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3694904

Deficiency record · 10

04 - Emergency Systems › N/A - No Subsystem › Shipboard Marine Pollution emergency operations
Issued 18 May 2026 Resolved
The owner or operator of all unmanned tank barges shall ensure that a copy of the vessel response plan and the Coast Guard approval letter or notarized copy of the approval letter are maintained aboard the barge. Provide copy of approval letter for the vessel's response plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2026
Resolved 18 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2026 Resolved
The owner, master, or person-in charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. One portable fire extinguisher is overdue for servicing. Provide a 40B fire extinguisher prior to operations.
Action required: 60 - Rectify deficiencies prior to movement
Due 18 May 2026
Resolved 19 May 2026
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 May 2019 Resolved
Replace hydraulic hoses, chaffed thru outer housing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2019
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 May 2019 Resolved
Cargo pump engine battery wire replace with non automotive battery connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2019
Resolved 9 May 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2019 Resolved
Replace grounding wire to fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2019
Resolved 9 May 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 6 May 2019 Resolved
Tow straps wasted, replace with new.
Condition: Damaged By Earlier Event
Action required: 703 - Prior to bunkering operations
Due 14 May 2019
Resolved 9 May 2019
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 May 2017 Resolved
Provide valid COD and have original on board available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: Provided valid copy to USCG MI and barge with original COD.
Documentation › Logs/Records › Drug Test Records
Issued 9 May 2017 Resolved
Provide proof of DAPI program and test records.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: Vessel provided proof of registration in drug consortium and proper DAPI program records.
Documentation › Markings/Placards › Warning Signs
Issued 9 May 2016 Resolved
Properly label tops of cargo hatches as per CFR.
Action required: 705 - Other - as specified
Resolved 9 May 2016
Resolution: Properly labeled tops of all cargo hatches as per CFR, on the spot.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 2 May 2016 Resolved
Prove proper operation of remote emergency shutdown, prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 10 May 2016
Resolution: Technician fixed remote switch from emergency shutdown, tested while at dock, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.