Records from 2012 to 2025. Most recent: inspection, 27 January 2025.
Inspection history · 21
27 January 2025
COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8068957
12 March 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7878031
12 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7647347
4 February 2023
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7631942
23 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7457009
20 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7374767
8 April 2021
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7170386
13 March 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7155586
13 January 2021
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7120493
8 September 2020
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7050336
24 January 2020
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895739
24 June 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6723658
24 May 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6704572
7 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637803
18 December 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6599643
23 March 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6385398
14 March 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6374755
7 February 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351040
1 March 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6098596
13 January 2017
Administrative Inspection · DAPI Audit · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6072686
26 January 2016
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5803894
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2024
Resolved
A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant [name withheld] steering tiller would not fit on rudder stock. Prove proper operation of the emergency tiller to the satisfaction of a Marine Inspector.
46 CFR 182.620(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 13 March 2024
Resolution: Owner sent a video showing proper operation of emergency tiller.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2024
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a): Not more than 49 passengers, 26 feet up to 65. 1 fixed power pump and 1 portable hand pump.
Vessel did not have a portable bilge pump. Supply bilge pump with adequate hose to reach all bilge areas and overboard discharge.
46 CFR 182.520(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 13 March 2024
Resolution: Received photos of new portable bilge pump and hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 March 2024
Resolved
A vessel must carry one floating waterlight. Waterlight for ring buoy was missing. Owner placed new light during inspection.
46 CFR 180.70(d)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 March 2024
Resolved 12 March 2024
Resolution: Owner provided new light and line.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 March 2024
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information: Date of the training, and general description of the training topics.
Man overboard, fire, and abandon ship drills have not been recorded since early 2023. Educated owner and master about drill recording requirements. Documented drills from today's inspection as well as EPIRB test.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 March 2024
Resolved 12 March 2024
Resolution: Recorded drills and EPIRB test from annual inspection. Educated master and owner's rep on proper drill/testing requirements.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 April 2023
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. Dead-end wires found in life jacket
stowage compartment. Remove/make wire in compliance with
regulations to satisfaction of attending Marine
Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 28 April 2023
Resolution: Attested to removing dead-end wire and making in compliance with regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 April 2023
Resolved
Each disposable hydrostatic release unit (HRU) must be
marked with an expiration date of two years after the
date on which the unit is installed. Expiry markings on
vessel's IBA & EPIRB HRU were either non-existent or
marked after two year manufacturer stated expiration.
Prove correct expiry marking on HRU's to manufacturer
specifications. Make satisfactory to attending Marine
Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 28 April 2023
Resolution: Provided objective evidence in the form of photos showing HRU's compliance.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 February 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry-dock examination and an internal structural examination at least once every two years. As per her COI, JOURNEY is currently outside compliance and can no longer operate under the conditions of her COI. The vessel may operate in the following alternative services, within the limits of the vessel’s current stability letter:
(a) as a small passenger vessel, carrying 6 or less passengers without deck cargo, with one licensed master.
(b) as a bareboat chartered recreational vessel carrying 12 or less passengers with no crew provided by the Owner/Operator.
Vessel must undergo a satisfactory dry-docking in compliance with 46 CFR Sub-chapter T, in the presence of a USCG Marine Inspector, in order to clear this deficiency.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2023
Resolution: Vessel underwent a satisfactory dry-docking in compliance with 46 CFR Sub-chapter T, in the presence of a USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 20 April 2022
Resolved
Strong and effective rudder stops must be provided to
prevent jamming and damage to the rudder and its
fittings. These stops may be structural or internal to
the main steering gear. Vessel did not have rudder
stops. Make rudder stops as required as per regulation
and to the satisfaction of attending Marine Inspector
prior to receiving credit for next dry-docking.
Action required: 705 - Other - as specified
Resolved 12 April 2023
Resolution: Made rudder stops as required as per regulation and to the satisfaction of attending Marine Inspector prior to receiving credit for next annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 April 2021
Resolved
Fireboy not shutting down engine on testing. Demonstrate proper operation of Fireboy shutdown and override.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 April 2021
Resolved 8 April 2021
Resolution: Vessel corrected the same day by replacing the override control bezel. Override switch was stuck in the active position, preventing the shutdown function from working.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 April 2021
Resolved
Forward bilge high level alarm not able to be seen or heard. Demonstrate proper operation.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 8 April 2021
Resolved 8 April 2021
Resolution: Upon investigatin vessel determined that the cause was a loose wire. Upon ensuring good connection vessel demonstrated alarm function.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2021
Resolved
Portable fire extinguisher under console not serviced. Provide proeprly serviced extinguisher.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 8 April 2021
Resolution: Vessel provided replacement extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 April 2021
Resolved
Machinery space ventilation covers missing securing snaps. Demonstrate proepr and adequate ventilation covers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 8 April 2021
Resolution: Vessel replaced missing snaps and demonstrated installation.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 April 2021
Resolved
Vessel log not on board or available for inspection. Provide logs showing drills, EPIRB tests and portable fire extinguisher inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 19 April 2021
Resolution: Vessel provided logbooks.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 April 2021
Resolved
Aspirin in first aid kit expired. Replace aspirin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 8 April 2021
Resolution: Vessel provided replacement aspirin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2021
Resolved
Ring buoy water light found leaking and full of water. Provide replacement water light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 19 April 2021
Resolution: Vessel provided replacement water light.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 February 2020
Resolved
Engine override for the vessels installed fire suppression system is inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2020
Resolved 5 March 2020
Resolution: Owner sent in documentation attesting to the service of the vessels installed fire suppresion system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2020
Resolved
03-life jackets need new retro.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 11 February 2020
Resolution: O/O replaced retro.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 February 2020
Resolved
First aid kit was found to be water logged and and had expired items in it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: Vessel purchased new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 February 2020
Resolved
Life jacket donning plaque was unreadable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: Vessel replaced life jacket instructions.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2020
Resolved
P/S nav lights were not working.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 4 February 2020
Resolution: Vessel replaced P/S running lights.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 February 2020
Resolved
Emergency instructions posted were unreadable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: Vessel replaced emergency instructions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2020
Resolved
Oil discharge prohibited plaques was unreadable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 4 February 2020
Resolution: Vessel replaced oil discharge plaque.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 February 2018
Resolved
VHF Radio does not have GPS capability and does not have the MMSI number programmed 46 CFR 184.502
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Radio installed with GPS and DSC.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 February 2018
Resolved
Replace expired lifebuoy light bsttery 46 CFR 180.70 & 46 CFR 160.050
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Battery replaced and tested.
Personnel › Training › Passenger Safety
Issued 26 February 2018
Resolved
Conduct & Document drills and training with crew 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2018
Resolved 23 March 2018
Resolution: Drills were conducted and written in log.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 February 2017
Resolved
Owner shall provide evidence of fire fighting servicing and make portable fire fighting extinguishers available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2017
Resolved 1 March 2017
Resolution: Fire fighting equipment mounted and inspected satisfactory.
Electrical › Mast › Lightning Ground
Issued 2 February 2017
Resolved
Vessels navigation lights must meet the inland navigation rules. Prove operation of navigation light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 1 March 2017
Resolution: Nav lights worked.
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 February 2017
Resolved
Post proper life jacket donning instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 1 March 2017
Resolution: Placard mounted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2017
Resolved
Remove all dead end un-used wiring under the operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 1 March 2017
Resolution: Dead end wires removed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2016
Resolved
All-around light inop. Ensure all-around light operational IAW 46 CFR 183.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 25 February 2016
Resolution: Replaced light and saw proper operation.
Documentation › Markings/Placards › Garbage Placard
Issued 23 February 2016
Resolved
Garbage plaque faded. Ensure garbage policy is legible IAW 33 CFR 151.59.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 25 February 2016
Resolution: Replaced garbage placard
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 February 2016
Resolved
PFD donning instructions faded. Ensure donning instructions are legible IAW 46 CFR 185.516.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 25 February 2016
Resolution: Replaced doning instructions
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 February 2016
Resolved
PFD stowage labels faded. Ensure labels are renewed and legible IAW 46 CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 25 February 2016
Resolution: Replaced PFD stowage location placards
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 23 February 2016
Resolved
Both portable fire extinguishers shall be mounted at or adjacent to operating station with approved bracket type IAW 46 CFR 181.520.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 25 February 2016
Resolution: Vessel owner moved fire extinguishers to prescribed location and installed with new bracket.