Records from 2016 to 2020. Most recent: inspection, 13 December 2020.
Inspection history · 9
13 December 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7104421
27 April 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6944392
9 August 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6777964
5 July 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6736807
26 June 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6726200
11 February 2019
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6622639
16 April 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6385807
19 December 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6055260
19 December 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6057734
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 16 April 2018
Resolved
The detection system shall initiate audible and visual alarms. During the engine room exam, it was observed that both the fire alarm detection light on the aft bulkhead adjacent to the auxillary generator, and the fire alarm detection light on the upper level transverse bulkhead were not operational.
74SOLAS(14)II-2/7.4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2018
Resolved 22 April 2018
Resolution: Class report attests to repair and proper operation
Fire Fighting › Water Fog Applicators › Condition
Issued 16 April 2018
Resolved
No change shall be made to the structural arrangements, machinery, equipment and other items covered by the survey without the approval of the administration. The water mist air horn housing was repaired with epoxy
74SOLAS(14)I/II
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2018
Resolved 22 April 2018
Resolution: Class report attests to repair and proper operation
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 16 April 2018
Resolved
Means shall be provided to control leaks of flammable liquids. 05 fuel injection pumps were observed to be leaking.
74SOLAS(14)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2018
Resolved 22 April 2018
Resolution: Class report attests to repair and proper operation
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 April 2018
Resolved
No change shall be made to the structural arrangements, machinery, equipment and other items covered by the survey without the approval of the admininstration. The #2 heavy fuel oil service tank drain valve has been re-routed to the ship's diesel oil transfer pump strainer for re-circulation purposes.
74SOLAS(14)I/II
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2019
Resolution: Class report showing re-routed piping has beeb removed.
Operations/Management › Vessel Activity › Cleaning/Stripping
Issued 16 April 2018
Resolved
Remove fouling organisms from the vessel's hull, piping and tanks on a regular basis, and dispose of any removed substances in accordance with local, state, and federal regulations. Vessel has excess growth about the hull at waterline and below.
33CFR151.2050(f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2019
Resolution: Received hull cleaning report showing before and after pictures of cleaning.