MAURY USCG vessel records Sign in
← All vessels

HIGH MAINTENANCE

HIGH MAINTENANCE is a 2010 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2010, most recently in April 2026, along with 34 deficiencies.

Records from 2010 to 2026. Most recent: inspection, 10 April 2026.

Built
2010
Last inspected
10 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF8909
1056415
Flag
UNITED STATES
367499860 (licence lapsed)
Maury page id
psix-1056415

Inspections, by type

Years with a record 13 calendar years (2010–2026)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2010
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE OZARK, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF8909MMSI 367499860 · expired · voluntarily equipped · granted 21 July 2011, cancelled 9 October 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 22

10 April 2026 Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8320860
10 June 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8156629
10 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8081471
29 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7899473
17 April 2023 Deficiency Check · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7654552
27 April 2022 COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7417258
5 May 2021 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7190082
6 July 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6998699
21 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6690572
3 May 2019 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6676292
11 April 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6660647
11 May 2018 Initial Certification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6414426
23 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6342430
1 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6136752
7 February 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6083953
5 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5931558
24 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5886474
12 April 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5852873
11 February 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5813941
12 January 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796131
28 February 2012 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4250262
15 March 2010 Initial Certification · Hull Examination · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3695943

Deficiency record · 34

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 April 2026 Resolved
Any vessel of at least 5 net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. The vessels COD was expired. All deficiencies and a an annual inspection shall be completed prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: Owner provided a new COD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 April 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The lower drive unit is being replaced in the shop. All deficiencies and a an annual inspection shall be completed prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 March 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Found numerous items to be expired. Replace prior to passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2025
Resolution: Received photo of new first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2024 Resolved
46 CFR 180.20(d) A vessel must carry one floating water light, unless it is limited to daytime operation. Battery for floating water light expired. Vessel is restricted to daytime operations until rectified.
Action required: 705 - Other - as specified
Due 4 July 2024
Resolved 17 June 2024
Resolution: Received photo of new battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2024 Resolved
46 CFR 179.360 A vessel of more than 26' but less than 65' must carry a minimum of one life buoy of not less than 24" in diameter. Life buoy grab lines were dry rotted and need to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2024
Resolved 17 June 2024
Resolution: Replaced ring buoy.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 April 2023 Resolved
A vessel of less than 12 meters in length shall have means of making an efficient sound signal. There was no horn present at time of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. The COI allows for 13 pax and 01 crew. There are 13 serviceable life jackets on board. Vessel restricted to 12 pax and 01 crew.
Action required: 705 - Other - as specified
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 April 2023 Resolved
A vessel must carry a 1st aid kit approved under 46CFR160.041. The ammonia inhalants present on board were expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 17 April 2023 Resolved
Conduct and log crew training and drills to include fire drill, man overboard drill and abandon ship drill in accordance with 46 CFR 185.512, 185.520 and 185.524.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 June 2023
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 19 May 2021 Resolved
Conduct and log crew training and drills to include fire drill, Man Overboard drill and abandon ship drill in accordance with 46 CFR 185.512, 185.520 and 185.524.
Action required: 10 - Deficiency Rectified
Due 19 May 2021
Resolved 19 May 2021
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 July 2020 Resolved
Conduct and log fire and man overboard drills.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 July 2020
Resolved 15 July 2020
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2019 Resolved
Install required lanyard for attaching water light to life ring buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2019
Resolved 21 May 2019
Resolution: On this date, recieved email verification with photos from owner/operator attesting to the repair of the above deficiency.
Documentation › Certificates/Documents › FCC SSL
Issued 22 March 2017 Resolved
Need Radio Operators Permit
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 1 May 2017
Resolution: Operators permit completed.
Documentation › Logs/Records › Logbook (official)
Issued 22 March 2017 Resolved
Need drill logbook.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 1 May 2017
Resolution: Showed log book for drills.
Communications › Alarms/Indicators › High Water Alarm
Issued 22 March 2017 Resolved
High water, aft bidge, visual indicator needs to operate correctly.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 1 May 2017
Resolution: High water alarm working.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 26 April 2016 Resolved
No evidence of EAP training provided. Provide proof of completion of all required EAP training for crew and supervisors.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Provided proof of training.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 April 2016 Resolved
Indicator lights for installed submersible pumps did not light at operating station. Make indicator operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Renewed light.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 April 2016 Resolved
Vessel had outdated charts and publications. Provide updated charts, coast pilot, light list, and current tables for the area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 5 July 2016
Resolution: Updated charts and publications were provided
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 April 2016 Resolved
Audible alarm for pre-engineered fire system did not operate. Fix system to make audible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Fixed system.
Documentation › Certificates/Documents › FCC SSL
Issued 15 March 2010 Resolved
Provide FCC SSL, Radio Safety & Operators Permit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Resolution: The radio station authorization, the radio safety certificate and a radio operators permit where onboard the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2010 Resolved
Provide Nav Pubs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2016
Resolution: The required publications were already cleared with the exception of the rules to the road, which a new copy was onboard.
Communications › Audible Communications › Horn/Whistle
Issued 15 March 2010 Resolved
Provide SPD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2011
Resolution: Provided horn.
Lifesaving › Hand Flares › Not on Board
Issued 15 March 2010 Resolved
Provide VDS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2011
Resolution: The vessel was equipment with 6 and 6.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 March 2010 Resolved
Conduct Machinery Op test and New to Zone inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2011
Resolution: We got the vessel underway to conduct the drills and tested the machinery at that time.
Communications › Radio Communications › EPIRB
Issued 15 March 2010 Resolved
Provide EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Resolution: The FCC Type Accepted Category 1, 406 MHz EPIRB was registered to the High Maintenance stowed in a float free position.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 15 March 2010 Resolved
Provide anchor and mooring lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2011
Resolution: Provided anchor and lines.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 March 2010 Resolved
Provide PFD's
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2011
Resolution: Provided 14 adult and 2 child PFD''s
Lifesaving › Lifebuoys › Not on Board
Issued 15 March 2010 Resolved
Provide ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2011
Resolution: A new ring life buoy was properly mounted on the vessel with a water light attached.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 March 2010 Resolved
Provide 1st aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2011
Resolution: Provided first aid kit.
Fire Fighting › Fire Bucket › Availability
Issued 15 March 2010 Resolved
Provide fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2011
Resolution: There are three 2.5 gals. buckets properly stenciled with lines attached.
Engineering › Bilge Water Management System › Pump
Issued 15 March 2010 Resolved
Provide portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2011
Resolution: There is a portable bilge onboard and was tested.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 March 2010 Resolved
Provide portable lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2011
Resolution: Provided portable lighting.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 March 2010 Resolved
Conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2011
Resolution: Drills were conducted with satisfactory results.
Construction/Loadline › Hull › Bottom Plating
Issued 15 March 2010 Resolved
Provide repair procedure for miss-drilled area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2011
Resolution: Repaired miss drilled area.

Ownership record